Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT

被引:0
|
作者
Oechsner, Tim [1 ]
Soschynski, Martin [1 ]
Schlett, Christopher L. [1 ]
Krauss, Tobias [1 ]
Schupppert, Christopher [1 ]
Mueller-Peltzer, Katharina [1 ]
Vecsey-Nagy, Milan [3 ]
Kravchenko, Dmitrij [2 ,4 ]
Varga-Szemes, Akos
Emrich, Tilman [2 ,5 ]
Scheu, Raphael [6 ]
Taron, Jana [1 ]
Bamberg, Fabian [1 ]
Hagar, Muhammad Taha [1 ,2 ]
机构
[1] Univ Freiburg, Med Ctr, Fac Med, Dept Diagnost & Intervent Radiol, Freiburg, Germany
[2] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, Charleston, SC USA
[3] Semmelweis Univ, Heart & Vasc Ctr, Budapest, Hungary
[4] Univ Hosp Bonn, Dept Diagnost & Intervent Radiol, Bonn, Germany
[5] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, Mainz, Germany
[6] Univ Cambridge, Sch Clin Med, Dept Publ Hlth & Primary Care, Cambridge, England
关键词
Aorta; CT; Photon-counting; Iodine; Contrast medium; COMPUTED-TOMOGRAPHY; CONTRAST MATERIAL; IMAGE QUALITY; ENERGY CT; RISK; MANAGEMENT;
D O I
10.1016/j.ejrad.2025.111919
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose. Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT. Images were acquired with fast pitch and full spectral capabilities (collimation 144 x 0.4 mm). The contrast protocol included a mixture of sodium chloride and iodinated contrast agent (Iopromide, total iodine dose: 9.5-9.8 g). Virtual monoenergetic images (VMIs) were reconstructed at 40, 50, 60, and 68 keV. Two blinded radiologists evaluated image quality on a 4-point scale. Attenuation was measured across eight regions in the aorta and iliac arteries, and contrast-to-noise ratio (CNR) was calculated. Statistical comparisons were performed using repeated measures ANOVA and Bonferroni post-hoc tests. Results: The final cohort consisted of 39 subjects (mean age: 69.6 +/- 9.6 years; 30.8 % female). VMI at 40 keV provided significantly higher attenuation: 478 +/- 114 HU, compared to 50 keV (331 +/- 74 HU), 60 keV (241 +/- 51 HU), and 68 keV (190 +/- 48 HU) (p < 0.01). This translated in increased CNR for 40 keV reconstructions (11.8 +/- 3.9), followed by 50 keV (9.1 +/- 3.0), 60 keV (7.0 +/- 2.3), and 68 keV (6.1 +/- 1.9) (p < 0.01). Subjective image quality was rated excellent at 40 keV (4 [3,4]), though associated with highest noise (38 +/- 7.4 HU, p = 0.02). Conclusion: Aortoiliac CTA using dual-source PCD-CT at 40 keV achieved high attenuation and CNR, enabling effective imaging with only 9.8 g of iodine.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] An introduction to photon-counting detector CT (PCD CT) for radiologists
    Nakamura, Yuko
    Higaki, Toru
    Kondo, Shota
    Kawashita, Ikuo
    Takahashi, Isao
    Awai, Kazuo
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (03) : 266 - 282
  • [42] The technical development of photon-counting detector CT
    Cynthia H. McCollough
    Kishore Rajendran
    Shuai Leng
    Lifeng Yu
    Joel G. Fletcher
    Karl Stierstorfer
    Thomas G. Flohr
    European Radiology, 2023, 33 : 5321 - 5330
  • [43] The technical development of photon-counting detector CT
    McCollough, Cynthia H.
    Rajendran, Kishore
    Leng, Shuai
    Yu, Lifeng
    Fletcher, Joel G.
    Stierstorfer, Karl
    Flohr, Thomas G.
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5321 - 5330
  • [44] AJR Forum on Photon-Counting Detector CT
    Dane, Bari
    Amrhein, Timothy J.
    Kay, Fernando
    Schwartz, Fides R.
    Toia, Giuseppe V.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (06)
  • [45] The Future Arrived Photon-Counting Detector CT
    Alkadhi, Hatem
    Runge, Val
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 439 - 440
  • [46] Abdominal image quality and dose reduction with energy-integrating or photon-counting detectors dual-source CT: A phantom study
    Greffiera, Joel
    Dabli, Djamel
    Faby, Sebastian
    Pastor, Maxime
    Croisille, Cedric
    de Oliveira, Fabien
    Erath, Julien
    Beregi, Jean Paul
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (10) : 379 - 385
  • [47] An introduction to photon-counting detector CT (PCD CT) for radiologists
    Yuko Nakamura
    Toru Higaki
    Shota Kondo
    Ikuo Kawashita
    Isao Takahashi
    Kazuo Awai
    Japanese Journal of Radiology, 2023, 41 : 266 - 282
  • [48] Photon-counting versus Dual-Source CT of Congenital Heart Defects in Neonates and Infants: Initial Experience
    Dirrichs, Timm
    Tietz, Eric
    Rueffer, Andre
    Hanten, Jens
    Nguyen, Thai Duy
    Dethlefsen, Ebba
    Kuhl, Christiane K.
    RADIOLOGY, 2023, 307 (05)
  • [49] Dual-source photon-counting CT: impact of residual cross-scatter on quantitative spectral results
    Liu, Leening P.
    Salazar, Edgar
    Sahbaee, Pooyan
    Litt, Harold I.
    Noel, Peter B.
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [50] Photon-Counting Detector CT Iodine Maps for Pituitary Adenoma in Cushing Disease
    Mark, Ian T.
    Yu, Lifeng
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (03)