Low-dose Ultra-high-resolution Photon-Counting Detector CT for Visceral Artery CT Angiography: A Preliminary Study

被引:3
|
作者
Wang, Lingyun [1 ]
Hu, Yangfan [2 ]
Zhong, Jingyu [2 ]
Yue, Xing [2 ]
Xu, Zhihan [3 ]
Ding, Bei [1 ]
Chu, Jingshen [4 ]
Yan, Fuhua [1 ]
Yao, Weiwu [2 ]
Zhang, Huan [1 ]
Hu, Weiguo [5 ,6 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Radiol, Shanghai 200025, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Tongren Hosp, Dept Radiol, Shanghai 200336, Peoples R China
[3] Siemens Healthineers Ltd, Shanghai 201318, Peoples R China
[4] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Editor,Journal Diag Concepts & Practice, Shanghai 200025, Peoples R China
[5] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Geriatr & Surg, Shanghai 200025, Peoples R China
[6] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Med Ctr Aging, Shanghai 200025, Peoples R China
关键词
Photon-counting detector CT; Computed tomography angiography; Ultra-high-resolution; COMPUTED-TOMOGRAPHY; RECONSTRUCTION;
D O I
10.1016/j.acra.2024.06.044
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To validate the image quality of low-dose ultra-high-resolution (UHR) scanning mode of photon-counting detector CT (PCD-CT) for visceral artery computed tomography angiography (CTA). Material and Methods: We prospectively enrolled 57 patients each in the full dose (FD) and low-dose (LD) protocols, respectively, to undergo abdominal CT scans using the UHR mode on a PCD-CT system (NAEOTOM Alpha), between April 2023 and September 2023. Both the FD data and LD data were then reconstructed into two series of images: (a) 0.2 mm slice thickness, reconstruction kernel Bv48, quantum iterative reconstruction (QIR) 4; (b)1 mm slice thickness, Bv40, QIR 3. The signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of seven arteries were objectively measured. The image noise, vessel sharpness, overall quality, and visibility of nine arteries were subjectively assessed by three radiologists. Results: The SNRs and CNRs of 0.2 mm reconstruction set was inferior to that of 1 mm reconstruction set (p < 0.001 for all the arteries and noise), however, the image quality of 0.2 mm reconstruction set was higher than that of 1 mm reconstruction set in qualitative evaluation especially for tiny arteries in Volume-rendered (VR) image (p < 0.001). The SNRs and CNRs were not significantly higher for FD group than LD group on the same slice thickness except for SNRs of common hepatic artery, splenic artery and bilateral renal arteries in 0.2 mm reconstruction set. In the comparison on image quality between normal weight and overweight patients within the same reconstruction set, the results showed that low-dose scan did not significantly impact the image quality in overweight patients. The ratings of visibility of nine visceral arteries were not significantly different among FD and LD at the same thickness reconstruction set except for superior mesenteric artery (p = 0.002 and 0.007 for 0.2 mm and 1 mm reconstruction set in axial image; p = 0.002 and 0.007 for 0.2 mm and 1 mm reconstruction set in coronal image, respectively) and left gastric artery (p = 0.002 and p < 0.001 for 0.2 mm and 1 mm reconstruction set in VR image, respectively). Conclusion: The low-dose UHR scanning mode of PCD-CT has proven to be adequate for the clinical evaluation of visceral arteries. Utilizing a reconstruction with a slice thickness of 0.2 mm could enhance arterial depiction, particularly for small vessels.
引用
收藏
页码:5087 / 5099
页数:13
相关论文
共 50 条
  • [1] Optimization of the Reconstruction Settings for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lungs
    Graafen, Dirk
    Halfmann, Moritz C.
    Emrich, Tilman
    Yang, Yang
    Kreuter, Michael
    Dueber, Christoph
    Kloeckner, Roman
    Mueller, Lukas
    Jorg, Tobias
    DIAGNOSTICS, 2023, 13 (23)
  • [2] Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung
    Sartoretti, Thomas
    Racine, Damien
    Mergen, Victor
    Jungblut, Lisa
    Monnin, Pascal
    Flohr, Thomas G.
    Martini, Katharina
    Frauenfelder, Thomas
    Alkadhi, Hatem
    Euler, Andre
    DIAGNOSTICS, 2022, 12 (02)
  • [3] Coronary Stenosis Quantification With Ultra-High-Resolution Photon-Counting Detector CT Angiography
    Eberhard, Matthias
    Candreva, Alessandro
    Rajagopal, Rengarajan
    Mergen, Victor
    Sartoretti, Thomas
    Stahli, Barbara E.
    Templin, Christian
    Manka, Robert
    Alkadhi, Hatem
    JACC-CARDIOVASCULAR IMAGING, 2024, 17 (03) : 342 - 344
  • [4] Ultra-High-Resolution Coronary CT Angiography With Photon-Counting Detector CT Feasibility and Image Characterization
    Mergen, Victor
    Sartoretti, Thomas
    Baer-Beck, Matthias
    Schmidt, Bernhard
    Petersilka, Martin
    Wildberger, Joachim Ernst
    Euler, Andre
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2022, 57 (12) : 780 - 788
  • [5] Ultra-High-Resolution Photon-Counting Detector CT Arthrography of the Ankle: A Feasibility Study
    Luetkens, Karsten Sebastian
    Grunz, Jan-Peter
    Kunz, Andreas Steven
    Huflage, Henner
    Weissenberger, Manuel
    Hartung, Viktor
    Patzer, Theresa Sophie
    Gruschwitz, Philipp
    Erguen, Sueleyman
    Bley, Thorsten Alexander
    Feldle, Philipp
    DIAGNOSTICS, 2023, 13 (13)
  • [6] Ultra-high-resolution photon-counting detector CT for visualization of the brachial plexus
    Nakashima, Masahiro
    Kawai, Tatsuya
    Matsumoto, Kazuhisa
    Kawaguchi, Takatsune
    Urano, Misugi
    Kitera, Nobuo
    Itoh, Toshihide
    Hiwatashi, Akio
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [7] The Importance of Temporal Resolution for Ultra-High-Resolution Coronary Angiography: Evidence From Photon-Counting Detector CT
    Mergen, Victor
    Sartoretti, Thomas
    Cundari, Giulia
    Serifovic, Medina
    Higashigaito, Kai
    Allmendinger, Thomas
    Schmidt, Bernhard
    Flohr, Thomas
    Manka, Robert
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2023, 58 (11) : 767 - 774
  • [8] Ultra-high-resolution photon-counting CT of the lungs: a comparative study
    Van Ballaer, V.
    Dubbeldam, A.
    Cockmartin, L.
    Muscogiuri, E.
    Coolen, J.
    Coudyzer, W.
    De Wever, W.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [9] Ultra-high-resolution photon-counting CT: "Plus Ultra" in lung imaging?
    Milos, Ruxandra-Iulia
    EUROPEAN RADIOLOGY, 2024, 34 (03) : 1893 - 1894
  • [10] Ultra-high-resolution photon-counting CT: “Plus Ultra” in lung imaging?
    Ruxandra-Iulia Milos
    European Radiology, 2024, 34 : 1893 - 1894