Optimization of the Reconstruction Settings for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lungs

被引:2
|
作者
Graafen, Dirk [1 ]
Halfmann, Moritz C. [1 ,2 ]
Emrich, Tilman [1 ,2 ,3 ]
Yang, Yang [1 ]
Kreuter, Michael [4 ,5 ]
Dueber, Christoph [1 ]
Kloeckner, Roman [6 ]
Mueller, Lukas [1 ]
Jorg, Tobias [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, D-55131 Mainz, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Rhine Main, D-55131 Mainz, Germany
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, Charleston, SC 29425 USA
[4] Mainz Univ Med Ctr, Mainz Ctr Pulm Med, Dept Pneumol, D-55131 Mainz, Germany
[5] Marienhaus Clin Mainz, Dept Pulm Crit Care & Sleep Med, Mainz, Germany
[6] Univ Hosp Schleswig Holstein, Inst Intervent Radiol, Campus Lubeck, D-23569 Lubeck, Germany
关键词
photon-counting detector CT; lung; slice thickness; quantum iterative reconstruction; ultra-high resolution; IMAGE QUALITY; CHEST-CT; COMPUTED-TOMOGRAPHY; FEASIBILITY;
D O I
10.3390/diagnostics13233522
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Photon-counting detector computed tomography (PCD-CT) yields improved spatial resolution. The combined use of PCD-CT and a modern iterative reconstruction method, known as quantum iterative reconstruction (QIR), has the potential to significantly improve the quality of lung CT images. In this study, we aimed to analyze the impacts of different slice thicknesses and QIR levels on low-dose ultra-high-resolution (UHR) PCD-CT imaging of the lungs. Our study included 51 patients with different lung diseases who underwent unenhanced UHR-PCD-CT scans. Images were reconstructed using three different slice thicknesses (0.2, 0.4, and 1.0 mm) and three QIR levels (2-4). Noise levels were determined in all reconstructions. Three raters evaluated the delineation of anatomical structures and conspicuity of various pulmonary pathologies in the images compared to the clinical reference reconstruction (1.0 mm, QIR-3). The highest QIR level (QIR-4) yielded the best image quality. Reducing the slice thickness to 0.4 mm improved the delineation and conspicuity of pathologies. The 0.2 mm reconstructions exhibited lower image quality due to high image noise. In conclusion, the optimal reconstruction protocol for low-dose UHR-PCD-CT of the lungs includes a slice thickness of 0.4 mm, with the highest QIR level. This optimized protocol might improve the diagnostic accuracy and confidence of lung imaging.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung
    Sartoretti, Thomas
    Racine, Damien
    Mergen, Victor
    Jungblut, Lisa
    Monnin, Pascal
    Flohr, Thomas G.
    Martini, Katharina
    Frauenfelder, Thomas
    Alkadhi, Hatem
    Euler, Andre
    [J]. DIAGNOSTICS, 2022, 12 (02)
  • [2] Ultra-high-resolution photon-counting CT of the lungs: a comparative study
    Van Ballaer, V.
    Dubbeldam, A.
    Cockmartin, L.
    Muscogiuri, E.
    Coolen, J.
    Coudyzer, W.
    De Wever, W.
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [3] Ultra-High-Resolution Photon-Counting Detector CT Arthrography of the Ankle: A Feasibility Study
    Luetkens, Karsten Sebastian
    Grunz, Jan-Peter
    Kunz, Andreas Steven
    Huflage, Henner
    Weissenberger, Manuel
    Hartung, Viktor
    Patzer, Theresa Sophie
    Gruschwitz, Philipp
    Erguen, Sueleyman
    Bley, Thorsten Alexander
    Feldle, Philipp
    [J]. DIAGNOSTICS, 2023, 13 (13)
  • [4] Coronary Stenosis Quantification With Ultra-High-Resolution Photon-Counting Detector CT Angiography
    Eberhard, Matthias
    Candreva, Alessandro
    Rajagopal, Rengarajan
    Mergen, Victor
    Sartoretti, Thomas
    Stahli, Barbara E.
    Templin, Christian
    Manka, Robert
    Alkadhi, Hatem
    [J]. JACC-CARDIOVASCULAR IMAGING, 2024, 17 (03) : 342 - 344
  • [5] Potential of employing a quantum iterative reconstruction algorithm for ultra-high-resolution photon-counting detector CT of the hip
    Huflage, H.
    Grunz, J. -P
    Kunz, A. S.
    Patzer, T. S.
    Sauer, S. T.
    Christner, S. A.
    Petritsch, B.
    Erguen, S.
    Bley, T. A.
    Luetkens, K. S.
    [J]. RADIOGRAPHY, 2023, 29 (01) : 44 - 49
  • [6] Ultra-High-Resolution Coronary CT Angiography With Photon-Counting Detector CT Feasibility and Image Characterization
    Mergen, Victor
    Sartoretti, Thomas
    Baer-Beck, Matthias
    Schmidt, Bernhard
    Petersilka, Martin
    Wildberger, Joachim Ernst
    Euler, Andre
    Eberhard, Matthias
    Alkadhi, Hatem
    [J]. INVESTIGATIVE RADIOLOGY, 2022, 57 (12) : 780 - 788
  • [7] Ultra-high-resolution photon-counting CT: "Plus Ultra" in lung imaging?
    Milos, Ruxandra-Iulia
    [J]. EUROPEAN RADIOLOGY, 2024, 34 (03) : 1893 - 1894
  • [8] Improvement of coronary stent visualization using ultra-high-resolution photon-counting detector CT
    Qin, Le
    Zhou, Shanshui
    Dong, Haipeng
    Li, Jiqiang
    Zhang, Ruiyan
    Yang, Chendie
    Liu, Peng
    Xu, Zhihan
    Yan, Fuhua
    Yang, Wenjie
    [J]. EUROPEAN RADIOLOGY, 2024,
  • [9] Ultra-high-resolution photon-counting CT: “Plus Ultra” in lung imaging?
    Ruxandra-Iulia Milos
    [J]. European Radiology, 2024, 34 : 1893 - 1894
  • [10] Ultra-high-resolution photon-counting detector computed tomography of the lungs: Phantom and clinical assessment of radiation dose and image quality
    Chamberlin, Jordan H.
    Smith, Carter D.
    Maisuria, Dhruw
    Parrish, Joe
    van Swol, Elizabeth
    Mah, Eugene
    Emrich, Tilman
    Schoepf, U. Joseph
    Varga-Szemes, Akos
    O'Doherty, Jim
    Munden, Reginald F.
    Tipnis, Sameer, V
    Baruah, Dhiraj
    Kabakus, Ismail M.
    [J]. CLINICAL IMAGING, 2023, 104