Low-dose lung cancer screening with photon-counting CT: a feasibility study

被引:82
|
作者
Symons, Rolf [1 ]
Cork, Tyler E. [1 ]
Sahbaee, Pooyan [2 ]
Fuld, Matthew K. [2 ]
Kappler, Steffen [3 ]
Folio, Les R. [1 ]
Bluemke, David A. [1 ]
Pourmorteza, Amir [1 ]
机构
[1] NIH, Radiol & Imaging Sci, Ctr Clin, Bldg 10, Bethesda, MD 20892 USA
[2] Siemens Med Solut, Malvern, PA USA
[3] Siemens Healthcare GmbH, Forchheim, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 01期
关键词
computed tomography; photon-counting CT; lung imaging; lung cancer screening; ground-glass nodule; emphysema; low-contrast detectability; COMPUTED-TOMOGRAPHY; CHEST CT; MODEL;
D O I
10.1088/1361-6560/62/1/202
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To evaluate the feasibility of using a whole-body photon-counting detector (PCD) CT scanner for low-dose lung cancer screening compared to a conventional energy integrating detector (EID) system. Radiation dose-matched EID and PCD scans of the COPDGene 2 phantom were acquired at different radiation dose levels (CTDIvol: 3.0, 1.5, and 0.75 mGy) and different tube voltages (120, 100, and 80 kVp). EID and PCD images were compared for quantitative Hounsfield unit (HU) accuracy, noise levels, and contrast-to-noise ratios (CNR) for detection of ground-glass nodules (GGN) and emphysema. The PCD HU accuracy was better than EID for water at all scan parameters. PCD HU stability for lung, GGN and emphysema regions were superior to EID and PCD attenuation values were more reproducible than EID for all scan parameters (all P < 0.01), while HUs for lung, GGN and emphysema ROIs changed significantly for EID with decreasing dose (all P < 0.001). PCD showed lower noise levels at the lowest dose setting at 120, 100 and 80 kVp (15.2 +/- 0.3 HU versus 15.8 +/- 0.2 HU, P = 0.03; 16.1 +/- 0.3 HU versus 18.0 +/- 0.4 HU, P = 0.003; and 16.1 +/- 0.3 HU versus 17.9 +/- 0.3 HU, P = 0.001, respectively), resulting in superior CNR for evaluation of GGNs and emphysema at 100 and 80 kVp. PCD provided better HU stability for lung, ground-glass, and emphysema-equivalent foams at lower radiation dose settings with better reproducibility than EID. Additionally, PCD showed up to 10% less noise, and 11% higher CNR at 0.75 mGy for both 100 and 80 kVp. PCD technology may help reduce radiation exposure in lung cancer screening while maintaining diagnostic quality.
引用
收藏
页码:202 / 213
页数:12
相关论文
共 50 条
  • [1] Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast
    Kalender, Willi A.
    Kolditz, Daniel
    Steiding, Christian
    Ruth, Veikko
    Lueck, Ferdinand
    Rossler, Ann-Christin
    Wenkel, Evelyn
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (03) : 1081 - 1086
  • [2] Technical feasibility proof for high-resolution low-dose photon-counting CT of the breast
    Willi A. Kalender
    Daniel Kolditz
    Christian Steiding
    Veikko Ruth
    Ferdinand Lück
    Ann-Christin Rößler
    Evelyn Wenkel
    [J]. European Radiology, 2017, 27 : 1081 - 1086
  • [3] Low-Dose High-Resolution Photon-Counting CT of the Lung: Radiation Dose and Image Quality in the Clinical Routine
    Woeltjen, Matthias Michael
    Niehoff, Julius Henning
    Michael, Arwed Elias
    Horstmeier, Sebastian
    Moenninghoff, Christoph
    Borggrefe, Jan
    Kroeger, Jan Robert
    [J]. DIAGNOSTICS, 2022, 12 (06)
  • [4] Lung Cancer Screening With Low-Dose CT
    Gjermundson, Hali J.
    Clark, Kevin R.
    [J]. RADIOLOGIC TECHNOLOGY, 2019, 90 (04) : 336 - 343
  • [5] Lung cancer screening with low-dose CT
    Diederich, S
    Wormanns, D
    Heindel, W
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (01) : 2 - 7
  • [6] SCREENING FOR LUNG CANCER WITH LOW-DOSE CT
    Coche, E.
    [J]. JBR-BTR, 2008, 91 (01): : 1 - 5
  • [7] Low-Dose CT for Lung Cancer Screening
    Kalra, Mannudeep K.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (05) : 719 - 720
  • [8] Low-dose CT for lung cancer screening
    Bach, Peter B.
    Brawley, Otis W.
    Silvestri, Gerard A.
    [J]. LANCET ONCOLOGY, 2018, 19 (03): : E133 - E134
  • [9] Feasibility of Low Dose Lung Cancer Screening with a Whole-Body Photon Counting CT: First Human Results
    Symons, R.
    Cork, T.
    Folio, L.
    Bluemke, D.
    Pourmorteza, A.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3835 - 3835
  • [10] Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung
    Sartoretti, Thomas
    Racine, Damien
    Mergen, Victor
    Jungblut, Lisa
    Monnin, Pascal
    Flohr, Thomas G.
    Martini, Katharina
    Frauenfelder, Thomas
    Alkadhi, Hatem
    Euler, Andre
    [J]. DIAGNOSTICS, 2022, 12 (02)