Investigating the Impact of Source Geometry and Distance on HPGe Detector Efficiency Using MCNPX Simulations

被引:0
|
作者
Rastgoo, Mazaher [1 ]
Sadremomtaz, Alireza [2 ]
机构
[1] Univ Guilan, Dept Phys, Univ Campus, Rasht, Iran
[2] Univ Guilan, Fac Sci, Dept Phys, Rasht, Iran
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2024年 / 139卷 / 12期
关键词
CALIBRATION; POINT; CODE;
D O I
10.1140/epjp/s13360-024-05891-9
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The most important characteristic of HPGe detector is its efficiency, which depends on the geometry of the source and the detector material. Normally, efficiency is function of the gamma energy and must be determined for each specific material that is subject of the measurements. This requires secondary standard for each material, and it is expensive and time-consuming process. Monte Carlo method can be helpful as an alternative computational method to calculate the efficiency of HPGe detector. This paper describes a procedure for constructing a Monte Carlo model of an HPGe detector used to measure activity. In this work, the HPGe detector was completely simulated by MCNPX computational code according to the laboratory conditions and geometry of the Marinelli source. Comparison has shown the average difference of about 10% between the experimental and the Monte Carlo simulation efficiency of the HPGe detector. The detector efficiency for the source in cylindrical geometry with various dimensions and different distances between the source and the detector was calculated and studied.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Accurate efficiency calibration of a low-energy HPGe detector using a monochromatic x-ray source
    Plagnard, Johann
    Bobin, Christophe
    Lepy, Marie-Christine
    X-RAY SPECTROMETRY, 2007, 36 (03) : 191 - 198
  • [22] A theoretical and experimental research on detection efficiency of HPGe detector for disc source with heterogeneous distribution
    Zi-ning Tian
    Xiao-ping Ouyang
    Lin-yue Liu
    Jin-lu Ruan
    Jin-liang Liu
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 304 : 905 - 910
  • [23] Research on detection efficiency of hpge detector without standard source calibration in carr laboratory
    Zhang N.-P.
    Ding L.
    1600, Atomic Energy Press (51): : 2326 - 2329
  • [24] Comparison of efficiency calibration techniques of HPGe detector for radioactivity measurement of soil sample in Marinelli geometry
    Van Doanh Ho
    Bao Quoc Hieu Phan
    Ngoc Son Pham
    Van Hoang Dao
    Hoang Duc Tam
    Manh Dung Ho
    Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 1361 - 1365
  • [25] A theoretical and experimental research on detection efficiency of HPGe detector for disc source with heterogeneous distribution
    Tian, Zi-ning
    Ouyang, Xiao-ping
    Liu, Lin-yue
    Ruan, Jin-lu
    Liu, Jin-liang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 304 (02) : 905 - 910
  • [26] Calibration HPGe detector using IAEA-U source for CBRNe
    Nascimento, Debora Siqueira
    Chierici, Andrea
    Ciolini, Riccardo
    Chiappini, Stefano
    d'Errico, Francesco
    Chiappini, Massimo
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (07):
  • [27] Comparison of efficiency calibration techniques of HPGe detector for radioactivity measurement of soil sample in Marinelli geometry
    Van Doanh Ho
    Bao Quoc Hieu Phan
    Ngoc Son Pham
    Van Hoang Dao
    Hoang Duc Tam
    Manh Dung Ho
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (03) : 1361 - 1365
  • [28] Efficiency and energy resolution of gamma spectrometry system with HPGe detector depending on variable source-to-detector distances
    Nurgül Hafızoğlu
    The European Physical Journal Plus, 139
  • [29] New Method of An HPGe Detector Precise Efficiency Calibration with Experimental Measurements and Monte Carlo Simulations
    Zhai, Y.
    Trache, L.
    Tribble, R.
    Liu, Y.
    Shi, C.
    Papanikolaou, N.
    Iacob, V.
    Hardy, J.
    Tabacaru, G.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [30] Efficiency and energy resolution of gamma spectrometry system with HPGe detector depending on variable source-to-detector distances
    Hafizoglu, Nurgul
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (02):