Calibration HPGe detector using IAEA-U source for CBRNe

被引:1
|
作者
Nascimento, Debora Siqueira [1 ,2 ]
Chierici, Andrea [2 ]
Ciolini, Riccardo [2 ]
Chiappini, Stefano [1 ]
d'Errico, Francesco [2 ]
Chiappini, Massimo [1 ]
机构
[1] Natl Inst Geophys & Volcanol, Via Vigna Murata 605, I-00143 Rome, Italy
[2] Univ Pisa, Dept Civil & Ind Engn, Lgo Lucio Lazzarino, I-56122 Pisa, PI, Italy
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2024年 / 139卷 / 07期
关键词
D O I
10.1140/epjp/s13360-024-05417-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Detecting and preventing the illicit movement of radioactive materials within a country is crucial, requiring the identification of radiologic anomalies against the normal radiation background. High-purity germanium (HPGe) detectors, known for their precision and sensitivity, have become popular for analyzing radioactive materials in CBRNe scenarios. This study focused on calibrating an HPGe detector for CBRNe applications, using gamma-ray spectra from an IAEA-U reference source. Energy calibration involved identifying peaks in the spectra and creating a calibration curve for energy and channel number data. Efficiency calibration, determined using the known activity of the source, revealed a linear relationship between energy and detector response. Over four years, systematic efficiency calibrations showed a deviation of only 3% well below the recommended limit of 5%. These findings underscore the reliability of the system as a reference spectrometry method for accurate detection of radioactive materials.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] FEPE calibration of a HPGe detector using radioactive sphere source
    Abbas, Mahmoud I.
    CONFERENCE ON THE APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY (CAARI 2016), 2017, 90 : 364 - 368
  • [2] Design of simulation gas calibration source for calibrating peak efficiency of HPGe detector
    Wang, Shi-Lian
    Li, Qi
    Fan, Yuan-Qing
    Liu, Shu-Jiang
    Chang, Yin-Zhong
    Jia, Huai-Mao
    Chen, Zhan-Ying
    Zhang, Xin-Jun
    Wang, Jun
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (07): : 773 - 777
  • [3] Accurate efficiency calibration of a low-energy HPGe detector using a monochromatic x-ray source
    Plagnard, Johann
    Bobin, Christophe
    Lepy, Marie-Christine
    X-RAY SPECTROMETRY, 2007, 36 (03) : 191 - 198
  • [4] Research on detection efficiency of hpge detector without standard source calibration in carr laboratory
    Zhang N.-P.
    Ding L.
    1600, Atomic Energy Press (51): : 2326 - 2329
  • [5] Calibration and Performance of HPGe Detector for Environmental Radioactivity Measurements using LabSOCS
    Shyti, Manjola
    10TH JUBILEE CONFERENCE OF THE BALKAN PHYSICAL UNION, 2019, 2075
  • [6] HPGE DETECTOR ABSOLUTE-PEAK-EFFICIENCY CALIBRATION BY USING THE ESOLAN PROGRAM
    WANG, TK
    MAR, WY
    YING, TH
    LIAO, CH
    TSENG, CL
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (09) : 933 - 944
  • [7] Efficiency calibration of a HPGe detector for the measurement of the primary coolant
    Qin, Guoxiu
    Liu, Yujuan
    Wu, Hexi
    Zhang, Huaiqiang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 310 (03) : 1033 - 1040
  • [8] EFFICIENCY CALIBRATION OF HPGE DETECTOR IN FAR AND CLOSE GEOMETRIES
    AKSOY, A
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 169 (02): : 463 - 469
  • [9] Efficiency calibration of a HPGe detector for the measurement of the primary coolant
    Guoxiu Qin
    Yujuan Liu
    Hexi Wu
    Huaiqiang Zhang
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 310 : 1033 - 1040
  • [10] XMASS detector calibration using a neutron source
    Ichimura, K.