Calibration HPGe detector using IAEA-U source for CBRNe

被引:1
|
作者
Nascimento, Debora Siqueira [1 ,2 ]
Chierici, Andrea [2 ]
Ciolini, Riccardo [2 ]
Chiappini, Stefano [1 ]
d'Errico, Francesco [2 ]
Chiappini, Massimo [1 ]
机构
[1] Natl Inst Geophys & Volcanol, Via Vigna Murata 605, I-00143 Rome, Italy
[2] Univ Pisa, Dept Civil & Ind Engn, Lgo Lucio Lazzarino, I-56122 Pisa, PI, Italy
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2024年 / 139卷 / 07期
关键词
D O I
10.1140/epjp/s13360-024-05417-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Detecting and preventing the illicit movement of radioactive materials within a country is crucial, requiring the identification of radiologic anomalies against the normal radiation background. High-purity germanium (HPGe) detectors, known for their precision and sensitivity, have become popular for analyzing radioactive materials in CBRNe scenarios. This study focused on calibrating an HPGe detector for CBRNe applications, using gamma-ray spectra from an IAEA-U reference source. Energy calibration involved identifying peaks in the spectra and creating a calibration curve for energy and channel number data. Efficiency calibration, determined using the known activity of the source, revealed a linear relationship between energy and detector response. Over four years, systematic efficiency calibrations showed a deviation of only 3% well below the recommended limit of 5%. These findings underscore the reliability of the system as a reference spectrometry method for accurate detection of radioactive materials.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Detection of WIMPs using low threshold HPGe detector
    Yue, Q
    Cheng, JP
    Li, YJ
    Li, J
    Wang, ZJ
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (08): : 877 - 880
  • [42] Constraining solar hidden photons using HPGe detector
    Horvat, R.
    Kekez, D.
    Krcmar, M.
    Krecak, Z.
    Ljubicic, A.
    PHYSICS LETTERS B, 2013, 721 (4-5) : 220 - 223
  • [43] Detector efficiency calibration using 88Rb point source
    Cosar, C.
    Luca, A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (06) : 2629 - 2637
  • [44] Efficiency calibration technology of 133Xe gas by efficiency transfer code of 133Ba disk source for HPGe detector
    Tian, Zining
    Ouyang, Xiaoping
    Liu, Yang
    Zhang, Xiaodong
    Liu, Linyue
    Zhang, Jianfu
    Liu, Jun
    Ruan, Jinlu
    Zhang, Zhongbing
    Zeng, Ming
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2014, 26 (09):
  • [45] Efficiency calibration of an HPGe detector in the 0.1–2.5 MeV energy range for Am-Be neutron source-based PGAA applications
    Ş. Turhan
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 273 : 443 - 450
  • [46] Design of simulated-gas calibration source and self-attenuation correction methods for radioactive noble gas measurement with HPGe detector
    Wang, Shuo
    Tuo, Fei
    Qiu, Xiang-ping
    Xiao, Yang
    Liang, Jun-cheng
    APPLIED RADIATION AND ISOTOPES, 2024, 206
  • [48] Preparation of calibration sources of 88Kr and 138Xe for HPGe detector
    Z. Y. Chen
    F. Xie
    X. H. Wang
    Y. F. Chang
    Z. B. Zhang
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 273 : 257 - 261
  • [49] THE ENERGY AND FWHM CALIBRATION OF A GAMMA SPECTROMETRIC SYSTEM WITH A HPGe DETECTOR ON THE BASIS OF THE BACKGROUND SPECTRUM
    Calin, M. R.
    Druker, A. E.
    ROMANIAN JOURNAL OF PHYSICS, 2011, 56 (7-8): : 920 - 927
  • [50] Preparation of calibration sources of 88Kr and 138Xe for HPGe detector
    Chen, Z. Y.
    Xie, F.
    Wang, X. H.
    Chang, Y. F.
    Zhang, Z. B.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 273 (01) : 257 - 261