Calibration HPGe detector using IAEA-U source for CBRNe

被引:1
|
作者
Nascimento, Debora Siqueira [1 ,2 ]
Chierici, Andrea [2 ]
Ciolini, Riccardo [2 ]
Chiappini, Stefano [1 ]
d'Errico, Francesco [2 ]
Chiappini, Massimo [1 ]
机构
[1] Natl Inst Geophys & Volcanol, Via Vigna Murata 605, I-00143 Rome, Italy
[2] Univ Pisa, Dept Civil & Ind Engn, Lgo Lucio Lazzarino, I-56122 Pisa, PI, Italy
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2024年 / 139卷 / 07期
关键词
D O I
10.1140/epjp/s13360-024-05417-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Detecting and preventing the illicit movement of radioactive materials within a country is crucial, requiring the identification of radiologic anomalies against the normal radiation background. High-purity germanium (HPGe) detectors, known for their precision and sensitivity, have become popular for analyzing radioactive materials in CBRNe scenarios. This study focused on calibrating an HPGe detector for CBRNe applications, using gamma-ray spectra from an IAEA-U reference source. Energy calibration involved identifying peaks in the spectra and creating a calibration curve for energy and channel number data. Efficiency calibration, determined using the known activity of the source, revealed a linear relationship between energy and detector response. Over four years, systematic efficiency calibrations showed a deviation of only 3% well below the recommended limit of 5%. These findings underscore the reliability of the system as a reference spectrometry method for accurate detection of radioactive materials.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Detection efficiency of NaI(Tl) detector based on the fabricated calibration of HPGe detector
    El-Gamal, Hany
    Negm, Hani
    Hasabelnaby, Mohamed
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2019, 12 (01) : 360 - 366
  • [12] Metrological tests of a 200 L calibration source for HPGE detector systems for assay of radioactive waste drums
    Boshkova, T.
    Mitev, K.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 114 - 117
  • [13] An empirical formula for HPGe γ detector efficiency calibration for bulky sources
    Nie Peng
    Ni Bang-fa
    Tian Wei-zhi
    RADIATION PHYSICS AND CHEMISTRY, 2012, 81 (01) : 9 - 11
  • [14] A semi-empirical formula for HPGe detector efficiency calibration
    Adesanmi, CA
    Balogun, FA
    Fasasi, MK
    Tubosun, IA
    Oladipo, AA
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 249 (03) : 607 - 611
  • [15] Calibration of HPGe detector for flowing sample neutron activation analysis
    F. S. Abdo
    Mohamed Soliman
    M. M. Ahmed
    R. A. M. Rizk
    R. M. Megahid
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 1413 - 1418
  • [16] Calibration of HPGe detector for flowing sample neutron activation analysis
    Abdo, F. S.
    Soliman, Mohamed
    Ahmed, M. M.
    Rizk, R. A. M.
    Megahid, R. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (02) : 1413 - 1418
  • [17] Precise efficiency calibration of an HPGe detector: source measurements and Monte Carlo calculations with sub-percent precision
    Hardy, JC
    Iacob, VE
    Sanchez-Vega, M
    Effinger, RT
    Lipnik, P
    Mayes, VE
    Willis, DK
    Helmer, RG
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) : 65 - 69
  • [18] Detector calibration at INM using a correlated photons source
    Ghazi-Bellouati, A.
    Razet, A.
    Bastie, J.
    Himbert, M. E.
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2006, 35 (03): : 211 - 216
  • [19] Calibration of a portable HPGe detector using MCNP code for the determination of 137Cs in soils
    Gutierrez-Villanueva, J. L.
    Martin-Martin, A.
    Pena, V.
    Iniguez, M. P.
    de Celis, B.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2008, 99 (10) : 1520 - 1524
  • [20] Absolute calibration of 60Co by using sum-peak method and an HPGe detector
    Kim, IJ
    Park, CS
    Choi, HD
    APPLIED RADIATION AND ISOTOPES, 2003, 58 (02) : 227 - 233