Calibration HPGe detector using IAEA-U source for CBRNe

被引:1
|
作者
Nascimento, Debora Siqueira [1 ,2 ]
Chierici, Andrea [2 ]
Ciolini, Riccardo [2 ]
Chiappini, Stefano [1 ]
d'Errico, Francesco [2 ]
Chiappini, Massimo [1 ]
机构
[1] Natl Inst Geophys & Volcanol, Via Vigna Murata 605, I-00143 Rome, Italy
[2] Univ Pisa, Dept Civil & Ind Engn, Lgo Lucio Lazzarino, I-56122 Pisa, PI, Italy
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2024年 / 139卷 / 07期
关键词
D O I
10.1140/epjp/s13360-024-05417-3
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Detecting and preventing the illicit movement of radioactive materials within a country is crucial, requiring the identification of radiologic anomalies against the normal radiation background. High-purity germanium (HPGe) detectors, known for their precision and sensitivity, have become popular for analyzing radioactive materials in CBRNe scenarios. This study focused on calibrating an HPGe detector for CBRNe applications, using gamma-ray spectra from an IAEA-U reference source. Energy calibration involved identifying peaks in the spectra and creating a calibration curve for energy and channel number data. Efficiency calibration, determined using the known activity of the source, revealed a linear relationship between energy and detector response. Over four years, systematic efficiency calibrations showed a deviation of only 3% well below the recommended limit of 5%. These findings underscore the reliability of the system as a reference spectrometry method for accurate detection of radioactive materials.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Investigating the Impact of Source Geometry and Distance on HPGe Detector Efficiency Using MCNPX Simulations
    Rastgoo, Mazaher
    Sadremomtaz, Alireza
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (12):
  • [22] Efficiency calibration of HPGe detector in a PGNAA system for the measurement of aqueous samples
    Cheng, Can
    Jia, Wenbao
    Hei, Daqian
    Li, Jiatong
    Cai, Pingkun
    Zhao, Dong
    Wei, Zhiyong
    APPLIED RADIATION AND ISOTOPES, 2019, 145 : 1 - 6
  • [23] Detection efficiency calibration of radioactive standard soil matter with HPGe detector
    Beijing Radiation Environment Management Center, Beijing 100089, China
    不详
    Yuanzineng Kexue Jishu, 2006, 6 (749-751):
  • [24] Re-construction of a HPGe detector precise modeling for efficiency calibration
    Zhang, Changfan
    Hu, Guangchun
    Zeng, Jun
    Xiang, Qingpei
    Guo, Xiaofeng
    Gong, Jian
    APPLIED RADIATION AND ISOTOPES, 2022, 180
  • [25] Efficiency function of an area source of HPGe γ detector and its applications
    Wang, Chongjie
    Cheng, Song
    Zhang, Ailian
    He Jishu/Nuclear Techniques, 2007, 30 (05): : 438 - 441
  • [26] Efficiency calibration of HPGe detectors for volume-source geometries
    Sharshar, T
    Elnimr, T
    ElHusseiny, FA
    ElAbd, A
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (05) : 695 - 697
  • [27] Efficiency transfer in the calibration of a coaxial p-type HpGe detector using the Monte Carlo method
    Vargas, MJ
    Díaz, NC
    Sánchez, DP
    APPLIED RADIATION AND ISOTOPES, 2003, 58 (06) : 707 - 712
  • [28] HPGe detector efficiency calibration for extended cylinder and Marinelli-Beaker sources using the ESOLAN program
    Wang, TK
    Mar, WY
    Ying, TH
    Tseng, CL
    Liao, CH
    Wang, MY
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (01) : 83 - 95
  • [29] EFFICIENCY CALIBRATION OF A WELL-TYPE HPGe DETECTOR USING EXPERIMENTAL AND MONTE CARLO SIMULATION TECHNIQUES
    Dalaka, Ekaterini
    Kuburas, Georgios
    Eleftheriadis, Konstantinos
    Anagnostakis, Marios J.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2020, 35 (02): : 121 - 129
  • [30] USING A CYCLOTRON PLUS ECR SOURCE FOR DETECTOR EVALUATION AND CALIBRATION
    MCMAHAN, MA
    WOZNIAK, GJ
    LYNEIS, CM
    BOWMAN, DR
    CHARITY, RJ
    LIU, ZH
    MORETTO, LG
    KEHOE, WL
    MIGNEREY, AC
    NAMBOODIRI, MN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 253 (01): : 1 - 9