Detector efficiency calibration using 88Rb point source

被引:0
|
作者
Cosar, C. [1 ]
Luca, A. [2 ]
机构
[1] Univ Bucharest, Fac Phys, 405 Str Atomistilor, Magurele, Romania
[2] Natl Inst R&D Phys & Nucl Engn Horia Hulubei IFIN, POB MG 6, Magurele 077125, Romania
关键词
MCNP; Gamma-ray spectrometry; Radiation detectors efficiency; COINCIDENCE SUMMING CORRECTIONS; HPGE DETECTOR; SPECTRUM; TOOL;
D O I
10.1007/s10967-024-09478-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A coaxial type HPGe detector, and two lanthanide scintillation type detectors have been modeled and characterized by means of Monte Carlo method implemented using the MCNP code. The isotope of interest is Rb-88 which decays with energies up to 5 MeV, and can in theory aid in extending the efficiency calibration of the installations of interest in higher gamma rays energies. An Eu-152 point source was used for the experimental validation of the MCNP models and excellent agreement was observed between the experimental data and the simulated data of both Eu-152 and Rb-88 point sources. After the experimental validation of the model, the efficiency calibration was extended for three different source-to-detector distances and the results are presented in this work.
引用
收藏
页码:2629 / 2637
页数:9
相关论文
共 50 条
  • [1] 88Rb半衰期的测定
    王世联
    白涛
    凡金龙
    李奇
    张小林
    何小兵
    师全林
    卢嘉春
    常永福
    原子能科学技术, 2009, 43 (11) : 973 - 975
  • [2] DECAY OF 88KR AND LEVELS OF 88RB
    MEYER, RA
    MOMYER, FF
    SMITH, CF
    HICKS, HG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1969, 14 (12): : 1238 - &
  • [3] DECAY SCHEME OF 17.7 MIN 88RB
    HESS, R
    ROEHMER, FC
    GASSMANN, F
    VONLEDEB.T
    NUCLEAR PHYSICS A, 1969, A137 (01) : 157 - &
  • [4] LEVELS OF 88SR FROM DECAY OF 88RB
    RAGAINI, RC
    KNIGHT, JD
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (11): : 1450 - &
  • [5] LEVELS OF 88SR FROM DECAY OF 88RB
    RAGAINI, RC
    KNIGHT, JD
    NUCLEAR PHYSICS A, 1969, A125 (01) : 97 - +
  • [6] STRIPPING ANALYSIS OF 87RB(D,P)88RB REACTION
    RAPAPORT, J
    RAO, MN
    ROBINSON, RL
    FORD, JLC
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1969, 14 (12): : 1201 - &
  • [7] TRANSFER OF DETECTOR EFFICIENCY CALIBRATION FROM A POINT SOURCE TO OTHER GEOMETRIES USING ETNA SOFTWARE
    Radu, Daniela
    Stanga, Doru
    Sima, Octavian
    ROMANIAN REPORTS IN PHYSICS, 2010, 62 (01) : 57 - 64
  • [8] BETA DECAY OF 87KR 88KR AND 88RB
    LYCKLAMA, H
    ARCHER, NP
    KENNETT, TJ
    CANADIAN JOURNAL OF PHYSICS, 1969, 47 (04) : 393 - &
  • [9] Half-life determination of 88Rb using the 4πβ and 4πβγ-coincidence methods
    Chu Chengsheng
    Xiang Qingpei
    Zeng Jun
    Zhang Yingzeng
    Guo Xiaofeng
    Hao Fanhua
    Hu Guangchun
    Zhang Jianhua
    Yang Liang
    Liu Qiang
    Li Wei
    Cui Lili
    Liu Youhong
    APPLIED RADIATION AND ISOTOPES, 2020, 166
  • [10] Determination of β-decay feeding patterns of 88Rb and 88Kr using the Modular Total Absorption Spectrometer at ORNL HRIBF
    Shuai, P.
    Rasco, B. C.
    Rykaczewski, K. P.
    Fijalkowska, A.
    Karny, M.
    Wolinska-Cichocka, M.
    Grzywacz, R. K.
    Gross, C. J.
    Stracener, D. W.
    Zganjar, E. F.
    Batchelder, J. C.
    Blackmon, J. C.
    Brewer, N. T.
    Go, S.
    Cooper, M.
    Goetz, K. C.
    Johnson, J. W.
    Jost, C. U.
    King, T. T.
    Matta, J. T.
    Hamilton, J. H.
    Laminack, A.
    Miernik, K.
    Madurga, M.
    Miller, D.
    Nesaraja, C. D.
    Padgett, S.
    Paulauskas, S., V
    Rajabali, M. M.
    Ruland, T.
    Stepaniuk, M.
    Wang, E. H.
    Winger, J. A.
    PHYSICAL REVIEW C, 2022, 105 (05)