Detector efficiency calibration using 88Rb point source

被引:0
|
作者
Cosar, C. [1 ]
Luca, A. [2 ]
机构
[1] Univ Bucharest, Fac Phys, 405 Str Atomistilor, Magurele, Romania
[2] Natl Inst R&D Phys & Nucl Engn Horia Hulubei IFIN, POB MG 6, Magurele 077125, Romania
关键词
MCNP; Gamma-ray spectrometry; Radiation detectors efficiency; COINCIDENCE SUMMING CORRECTIONS; HPGE DETECTOR; SPECTRUM; TOOL;
D O I
10.1007/s10967-024-09478-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A coaxial type HPGe detector, and two lanthanide scintillation type detectors have been modeled and characterized by means of Monte Carlo method implemented using the MCNP code. The isotope of interest is Rb-88 which decays with energies up to 5 MeV, and can in theory aid in extending the efficiency calibration of the installations of interest in higher gamma rays energies. An Eu-152 point source was used for the experimental validation of the MCNP models and excellent agreement was observed between the experimental data and the simulated data of both Eu-152 and Rb-88 point sources. After the experimental validation of the model, the efficiency calibration was extended for three different source-to-detector distances and the results are presented in this work.
引用
收藏
页码:2629 / 2637
页数:9
相关论文
共 50 条
  • [21] Virtual point source efficiency calibration method for voluminous sample of radio-xenon based on efficiency function of point source
    Zining Tian
    Xiaoping Ouyang
    Zheng Li
    Yang Liu
    Ming Zeng
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 308 : 579 - 586
  • [22] EFFICIENCY OF AN HPGE DETECTOR IN DEPENDENCE ON SOURCE-DETECTOR GEOMETRY FOR POINT AND VOLUME SOURCES
    Svrkota, Nikola
    Antovic, Nevenka M.
    Zizic, Ranka
    Vucevic, Zeljko
    Andelic, Tomislav
    Berisaj, Benard
    Lastovicka-Medin, Gordana
    RAD 2015: THE THIRD INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH, 2015, : 155 - 159
  • [23] NUCLEAR SPIN HYPERFINE-STRUCTURE SEPARATION AND NUCLEAR MAGNETIC MOMENT OF 18-MIN 88RB
    BOUT, PAV
    DYMANUS, A
    EHLERS, VJ
    PRIOR, MH
    SHUGART, HA
    PHYSICAL REVIEW, 1968, 166 (04): : 1131 - &
  • [24] Design of simulation gas calibration source for calibrating peak efficiency of HPGe detector
    Wang, Shi-Lian
    Li, Qi
    Fan, Yuan-Qing
    Liu, Shu-Jiang
    Chang, Yin-Zhong
    Jia, Huai-Mao
    Chen, Zhan-Ying
    Zhang, Xin-Jun
    Wang, Jun
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (07): : 773 - 777
  • [25] DETECTOR-EFFICIENCY CALCULATION BASED ON POINT-SOURCE MEASUREMENT
    LIPPERT, J
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (08): : 1097 - 1103
  • [26] FEPE calibration of a HPGe detector using radioactive sphere source
    Abbas, Mahmoud I.
    CONFERENCE ON THE APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY (CAARI 2016), 2017, 90 : 364 - 368
  • [27] Simulation of germanium detector calibration using the Monte Carlo method:: comparison between point and surface source models
    Ródenas, J
    Burgos, MC
    Zarza, I
    Gallardo, S
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 55 - 58
  • [28] USING A CYCLOTRON PLUS ECR SOURCE FOR DETECTOR EVALUATION AND CALIBRATION
    MCMAHAN, MA
    WOZNIAK, GJ
    LYNEIS, CM
    BOWMAN, DR
    CHARITY, RJ
    LIU, ZH
    MORETTO, LG
    KEHOE, WL
    MIGNEREY, AC
    NAMBOODIRI, MN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 253 (01): : 1 - 9
  • [29] Full energy peak efficiency calibration of HPGe detector for point and extended sources using Monte Carlo code
    Chhavi Agarwal
    Sanhita Chaudhury
    A. Goswami
    M. Gathibandhe
    Journal of Radioanalytical and Nuclear Chemistry, 2011, 287 : 701 - 708
  • [30] Full energy peak efficiency calibration of HPGe detector for point and extended sources using Monte Carlo code
    Agarwal, Chhavi
    Chaudhury, Sanhita
    Goswami, A.
    Gathibandhe, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 287 (03) : 701 - 708