Efficiency calibration of a HPGe detector for the measurement of the primary coolant

被引:0
|
作者
Guoxiu Qin
Yujuan Liu
Hexi Wu
Huaiqiang Zhang
机构
[1] Shenyang Institute of Engineering,State Key Laboratory Breeding Base of Nuclear Resources and Environment
[2] East China University of Technology,undefined
关键词
Efficiency calibration; γ-ray spectrometry; Primary coolant; True coincidence summing correction;
D O I
暂无
中图分类号
学科分类号
摘要
This paper describes a method of calibrating the efficiency of a Ge γ-ray spectrometer. 226Ra and 232Th were selected to produce the soil calibration source, and then several γ-rays with high emission probabilities in 226Ra’s decay products and 232Th’s decay products, along with 2754 keV γ-rays of 24Na in the primary coolant sample of PWR, were employed to perform efficiency calibration. After self-absorption correction and true coincidence summing correction, we obtained the efficiency curve of a Φ70  ×  30 mm aqueous calibration source over the high energy range (1120–2754 keV).
引用
收藏
页码:1033 / 1040
页数:7
相关论文
共 50 条
  • [1] Efficiency calibration of a HPGe detector for the measurement of the primary coolant
    Qin, Guoxiu
    Liu, Yujuan
    Wu, Hexi
    Zhang, Huaiqiang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 310 (03) : 1033 - 1040
  • [2] Efficiency calibration of HPGe detector in a PGNAA system for the measurement of aqueous samples
    Cheng, Can
    Jia, Wenbao
    Hei, Daqian
    Li, Jiatong
    Cai, Pingkun
    Zhao, Dong
    Wei, Zhiyong
    APPLIED RADIATION AND ISOTOPES, 2019, 145 : 1 - 6
  • [3] EFFICIENCY CALIBRATION OF HPGE DETECTOR IN FAR AND CLOSE GEOMETRIES
    AKSOY, A
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 169 (02): : 463 - 469
  • [4] Comparison of efficiency calibration techniques of HPGe detector for radioactivity measurement of soil sample in Marinelli geometry
    Van Doanh Ho
    Bao Quoc Hieu Phan
    Ngoc Son Pham
    Van Hoang Dao
    Hoang Duc Tam
    Manh Dung Ho
    Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 1361 - 1365
  • [5] Comparison of efficiency calibration techniques of HPGe detector for radioactivity measurement of soil sample in Marinelli geometry
    Van Doanh Ho
    Bao Quoc Hieu Phan
    Ngoc Son Pham
    Van Hoang Dao
    Hoang Duc Tam
    Manh Dung Ho
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (03) : 1361 - 1365
  • [6] An empirical formula for HPGe γ detector efficiency calibration for bulky sources
    Nie Peng
    Ni Bang-fa
    Tian Wei-zhi
    RADIATION PHYSICS AND CHEMISTRY, 2012, 81 (01) : 9 - 11
  • [7] Detection efficiency of NaI(Tl) detector based on the fabricated calibration of HPGe detector
    El-Gamal, Hany
    Negm, Hani
    Hasabelnaby, Mohamed
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2019, 12 (01) : 360 - 366
  • [8] A semi-empirical formula for HPGe detector efficiency calibration
    Adesanmi, CA
    Balogun, FA
    Fasasi, MK
    Tubosun, IA
    Oladipo, AA
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 249 (03) : 607 - 611
  • [9] Efficiency calibration of a HPGe detector in the [46.54-2000] keV energy range for the measurement of environmental samples
    Daza, MJ
    Quintana, B
    García-Talavera, M
    Fernández, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 470 (03): : 520 - 532
  • [10] Detection efficiency calibration of radioactive standard soil matter with HPGe detector
    Beijing Radiation Environment Management Center, Beijing 100089, China
    不详
    Yuanzineng Kexue Jishu, 2006, 6 (749-751):