Accurate efficiency calibration of a low-energy HPGe detector using a monochromatic x-ray source

被引:15
|
作者
Plagnard, Johann [1 ]
Bobin, Christophe [1 ]
Lepy, Marie-Christine [1 ]
机构
[1] CEA, Lab Natl Henri Becquerel, F-91191 Gif Sur Yvette, France
关键词
D O I
10.1002/xrs.961
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
HPGe detector efficiency has been calibrated using complementary methods involving radioactive x-ray standards, reference synchrotron flux (Super ACO, LURE, France) and a monochromatic x-ray source (SOLEX), combined with Monte Carlo simulation. In the study described here, SCLEX was used to determine the thickness of detector components that create absorption sites in front of the active zone of the detector, by energy scanning in the vicinity of their K and L binding energies. The layers of aluminium (infrared shielding), nickel (electrical contact) and germanium (dead layer) have been measured. This approach ensures accurate determination of the thickness of each component and enables the detector efficiency calculation by Monte Carlo simulation. Differences between simulated data and experimental efficiency values are about 1-5% at energies above 1400 eV and reach 20% at lower energies. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 50 条
  • [1] Efficiency calibration of an HPGe X-ray detector for quantitative PIXE analysis
    Mulware, Stephen J.
    Baxley, Jacob D.
    Rout, Bibhudutta
    Reinert, Tilo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 332 : 95 - 98
  • [2] LOW-ENERGY X-RAY SOURCES UTILIZED AT NBS FOR DETECTOR CALIBRATION
    SPARROW, JH
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (11): : 1328 - 1328
  • [3] Efficiency calibration and surface mapping of an energy-dispersive detector with SOLEX: A compact tunable monochromatic X-ray source
    Menesguen, Y.
    Lepy, M. -C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 193 - 196
  • [4] METHOD OF CALIBRATION FOR LOW-ENERGY X-RAY BEAMS
    NUNNALLY, JE
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (06): : 878 - 880
  • [5] Choice of optimal target for monochromatic tunable X-ray source based on low-energy accelerator
    Lobko, A
    Lugovskaya, O
    ADVANCED RADIATION SOURCES AND APPLICATIONS, 2006, 199 : 47 - 54
  • [6] APPARATUS FOR LOW-ENERGY X-RAY-FLUORESCENCE USING AN AL K X-RAY SOURCE AND AN SI(LI) DETECTOR
    MUSKET, RG
    HOLMES, SJ
    X-RAY SPECTROMETRY, 1990, 19 (04) : 177 - 184
  • [7] Comparison of experimental and theoretical efficiency of HPGe X-ray detector
    Mohanty, B. P.
    Balouria, P.
    Garg, M. L.
    Nandi, T. K.
    Mittal, V. K.
    Govil, I. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 584 (01): : 186 - 190
  • [8] CRYOGENIC DEVICE FOR A LOW-ENERGY X-RAY SPACE DETECTOR
    TESTARD, OA
    LENY, J
    LESZCZYSZYN, J
    JEHANNO, C
    CHERON, C
    ROTHENFLUG, R
    GRIFFITH, M
    CRYOGENICS, 1974, 14 (09) : 509 - 510
  • [9] Evaluation of low-energy tailing parameters of a HPGe X-ray detector to be used in GUPIX software library for PIXE analysis
    Shariff, A
    Martinsson, BG
    Auzelyte, V
    Elfman, M
    Kristiansson, P
    Malmqvist, KG
    Nilsson, C
    Pallon, J
    Wegdén, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 219 : 110 - 114
  • [10] An analytical description of low-energy X-ray spectra in Si(Li) and HPGe detectors
    Lowe, BG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 439 (2-3): : 247 - 261