Accurate efficiency calibration of a low-energy HPGe detector using a monochromatic x-ray source

被引:15
|
作者
Plagnard, Johann [1 ]
Bobin, Christophe [1 ]
Lepy, Marie-Christine [1 ]
机构
[1] CEA, Lab Natl Henri Becquerel, F-91191 Gif Sur Yvette, France
关键词
D O I
10.1002/xrs.961
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
HPGe detector efficiency has been calibrated using complementary methods involving radioactive x-ray standards, reference synchrotron flux (Super ACO, LURE, France) and a monochromatic x-ray source (SOLEX), combined with Monte Carlo simulation. In the study described here, SCLEX was used to determine the thickness of detector components that create absorption sites in front of the active zone of the detector, by energy scanning in the vicinity of their K and L binding energies. The layers of aluminium (infrared shielding), nickel (electrical contact) and germanium (dead layer) have been measured. This approach ensures accurate determination of the thickness of each component and enables the detector efficiency calculation by Monte Carlo simulation. Differences between simulated data and experimental efficiency values are about 1-5% at energies above 1400 eV and reach 20% at lower energies. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 50 条
  • [21] Study of the response function of a HPGe detector for low-energy X-rays
    Lépy, MC
    Plagnard, J
    Ferreux, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 290 - 293
  • [22] Efficiency calibration of Si(Li) detector in low-energy region
    An, Zhu
    Liu, Man-Tian
    Wu, Ying
    Duan, Yan-Min
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2006, 40 (01): : 83 - 87
  • [23] A LOW-ENERGY X-RAY POLARIMETER
    RIEGLER, GR
    GARMIRE, G
    MOORE, W
    STEVENS, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (04): : 635 - &
  • [24] X-RAY AND GAMMA-RAY STANDARDS FOR DETECTOR EFFICIENCY CALIBRATION
    NICHOLS, AL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 286 (03): : 467 - 473
  • [25] LOW-ENERGY X-RAY PREIONIZATION SOURCE FOR DISCHARGE EXCITED LASERS
    LEVATTER, JI
    LI, ZZ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (11): : 1651 - 1654
  • [26] Low-energy continuous filtered X-ray measurement and dosimetry with a PIPS detector
    Teng, Zhongbin
    Song, Mingzhe
    RADIATION PHYSICS AND CHEMISTRY, 2021, 179
  • [27] Determination of X-ray mass attenuation coefficients using HPGe detector
    Sharanabasappa
    Kerur, B. R.
    Anilkumar, S.
    Hanumaiah, B.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (01) : 76 - 83
  • [28] INSTANTANEOUS X-RAY-IMAGING USING A LOW-ENERGY X-RAY SOURCE, SCINTILLATING FIBERS AND AN INTENSIFIED CAMERA
    IKHLEF, A
    SKOWRONEK, M
    ANNALES DE PHYSIQUE, 1994, 19 (05) : 61 - 62
  • [29] Monochromatic X-ray source for calibrating X-ray telescopes
    Arkadiev, V
    Bräuninger, H
    Burkert, W
    Bzhaumikhov, A
    Gorny, HE
    Langhoff, N
    Oppitz, A
    Rabe, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 455 (03): : 589 - 595
  • [30] Efficiency calibration of a Si(Li) detector in the low-energy region using electron bremsstrahlung
    Tschischgale, J
    Kuchler, D
    Lehnert, U
    Zschornack, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 400 (2-3): : 387 - 391