Efficiency and energy resolution of gamma spectrometry system with HPGe detector depending on variable source-to-detector distances

被引:3
|
作者
Hafizoglu, Nurgul [1 ]
机构
[1] Istanbul Univ, Fac Sci, Dept Phys, TR-34134 Vezneciler, Istanbul, Turkiye
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2024年 / 139卷 / 02期
关键词
CALIBRATION;
D O I
10.1140/epjp/s13360-024-04903-y
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The high-purity germanium (HPGe) detectors, which are one of the basic instruments in the experimental nuclear physics, are widely used in many areas such as the environmental radioactivity, neutron activation analysis and geology. This study reports the results of energy calibration, energy resolution and efficiency calculations for an HPGe detector (ORTEC), which are necessary to determine the quality of the measurement results obtained from a gamma spectrometry system. For the purpose of examining the effects of gamma-ray energy and the distance between the source and the detector on the detector efficiency, measurements were made at six different source-detector distances for a total of about fourteen energies of the point sources (133Ba, 109Cd, 137Cs, 57Co, 60Co, 152Eu, 22Na, and 65Zn). Basic data were obtained with this detector system for later studies.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Efficiency and energy resolution of gamma spectrometry system with HPGe detector depending on variable source-to-detector distances
    Nurgül Hafızoğlu
    The European Physical Journal Plus, 139
  • [2] COINCIDENCE SUMMING CORRECTIONS IN GE(LI)-SPECTROMETRY AT LOW SOURCE-TO-DETECTOR DISTANCES
    DEBERTIN, K
    SCHOTZIG, U
    NUCLEAR INSTRUMENTS & METHODS, 1979, 158 (2-3): : 471 - 477
  • [3] Experimental and MC determination of HPGe detector efficiency in the 40-2754 keV energy range for measuring point source geometry with the source-to-detector distance of 25 cm
    Dryak, Pavel
    Kovar, Petr
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1346 - 1349
  • [4] EFFICIENCY CALIBRATION OF A GE(LI) DETECTOR AT SHORT SOURCE-TO-DETECTOR DISTANCE
    KAWADE, K
    EZUKA, M
    YAMAMOTO, H
    SUGIOKA, K
    KATOH, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 190 (01): : 101 - 106
  • [5] Precise determination of HPGe detector efficiency for gamma spectrometry measurements of environmental samples with variable geometry and density
    Barrera, Manuel
    Casas-Ruiz, Melquiades
    Alonso, Jose J.
    Vidal, Juan
    NUKLEONIKA, 2017, 62 (01) : 47 - 59
  • [6] Gamma-ray efficiency of a HPGe detector as a function of energy and geometry
    Challan, Mohsen B.
    APPLIED RADIATION AND ISOTOPES, 2013, 82 : 166 - 169
  • [7] DEPENDENCE OF GE(LI) EFFICIENCY SLOPE ON SOURCE-TO-DETECTOR DISTANCE
    GRANT, PM
    NUCLEAR INSTRUMENTS & METHODS, 1975, 127 (03): : 371 - 372
  • [8] Efficiency calibrations of HPGe detector for PGNAA system
    Sangaroon, S.
    Ratanatongchai, W.
    Wichaisri, C.
    Picha, R.
    Khaweerat, S.
    Channuie, J.
    SIAM PHYSICS CONGRESS 2017 (SPC2017), 2017, 901
  • [9] Full-Energy peak efficiency of an NaI(Tl) detector with coincidence summing correction showing the effect of the source-to-detector distance
    El-Khatib, Ahmed M.
    Salem, Bohaysa A.
    Badawi, Mohamed S.
    Gouda, Mona M.
    Thabet, Abouzeid A.
    Abbas, Mahmoud I.
    CHINESE JOURNAL OF PHYSICS, 2017, 55 (02) : 478 - 489
  • [10] Gamma ray registration efficiency simulation of a HPGe detector with PHITS
    Bagramova, A.
    Zhumadilov, K.
    Endo, S.
    Kajimoto, T.
    Sakaguchi, A.
    Zeinulla, Zh
    Hoshi, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2025, 334 (01) : 381 - 387