Efficiency and energy resolution of gamma spectrometry system with HPGe detector depending on variable source-to-detector distances

被引:3
|
作者
Hafizoglu, Nurgul [1 ]
机构
[1] Istanbul Univ, Fac Sci, Dept Phys, TR-34134 Vezneciler, Istanbul, Turkiye
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2024年 / 139卷 / 02期
关键词
CALIBRATION;
D O I
10.1140/epjp/s13360-024-04903-y
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The high-purity germanium (HPGe) detectors, which are one of the basic instruments in the experimental nuclear physics, are widely used in many areas such as the environmental radioactivity, neutron activation analysis and geology. This study reports the results of energy calibration, energy resolution and efficiency calculations for an HPGe detector (ORTEC), which are necessary to determine the quality of the measurement results obtained from a gamma spectrometry system. For the purpose of examining the effects of gamma-ray energy and the distance between the source and the detector on the detector efficiency, measurements were made at six different source-detector distances for a total of about fourteen energies of the point sources (133Ba, 109Cd, 137Cs, 57Co, 60Co, 152Eu, 22Na, and 65Zn). Basic data were obtained with this detector system for later studies.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Determining the efficiency of a broad-energy HPGe detector using Monte Carlo simulations
    R. Britton
    J. Burnett
    A. Davies
    P. H. Regan
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 295 : 2035 - 2041
  • [42] Determining the efficiency of a broad-energy HPGe detector using Monte Carlo simulations
    Britton, R.
    Burnett, J.
    Davies, A.
    Regan, P. H.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 295 (03) : 2035 - 2041
  • [43] HPGe detector full-energy peak efficiency calculation for inhomogeneously activated samples
    Gacnik, Lojze
    Jacimovic, Radojko
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 311 (02) : 1315 - 1321
  • [44] Determination of full energy peak efficiency of HpGe detector from 59.5 to 1332.5 keV
    Gültekin, A
    Kaynak, G
    Gürler, O
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2006, 44 (04) : 281 - 286
  • [45] Dependence of the virtual point-detector location on HPGe detector dimensions and source energy in 80-1400 keV range
    Taheri, M. H.
    Sardari, D.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [46] HIGH ENERGY GAMMA-RAY DETECTOR WITH GOOD RESOLUTION
    DALLY, EB
    HOFSTADTER, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (05): : 658 - +
  • [47] PEAK ENERGY SHIFT DEPENDENT ON SOURCE POSITION IN GAMMA-RAY ENERGY MEASUREMENT BY USING A CLOSED-ENDED COAXIAL HPGE DETECTOR
    BAK, HI
    BAE, YD
    KIM, MS
    CHOI, HD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 366 (2-3): : 332 - 339
  • [48] Determination of efficiency of an aged HPGe detector for gaseous sources by self absorption correction and point source methods
    Sarangapani, R.
    Jose, M. T.
    Srinivasan, T. K.
    Venkatraman, B.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [49] Efficiency calibration of an HPGe detector in the 0.1–2.5 MeV energy range for Am-Be neutron source-based PGAA applications
    Ş. Turhan
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 273 : 443 - 450
  • [50] DETERMINATION OF THE EFFICIENCY OF A DETECTOR IN GAMMA-SPECTROMETRY OF LARGE-VOLUME SAMPLES
    TERTYSHNIK, EG
    KORSAKOV, AT
    SOVIET ATOMIC ENERGY, 1985, 58 (01): : 52 - 56