Efficiency and energy resolution of gamma spectrometry system with HPGe detector depending on variable source-to-detector distances

被引:3
|
作者
Hafizoglu, Nurgul [1 ]
机构
[1] Istanbul Univ, Fac Sci, Dept Phys, TR-34134 Vezneciler, Istanbul, Turkiye
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2024年 / 139卷 / 02期
关键词
CALIBRATION;
D O I
10.1140/epjp/s13360-024-04903-y
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The high-purity germanium (HPGe) detectors, which are one of the basic instruments in the experimental nuclear physics, are widely used in many areas such as the environmental radioactivity, neutron activation analysis and geology. This study reports the results of energy calibration, energy resolution and efficiency calculations for an HPGe detector (ORTEC), which are necessary to determine the quality of the measurement results obtained from a gamma spectrometry system. For the purpose of examining the effects of gamma-ray energy and the distance between the source and the detector on the detector efficiency, measurements were made at six different source-detector distances for a total of about fourteen energies of the point sources (133Ba, 109Cd, 137Cs, 57Co, 60Co, 152Eu, 22Na, and 65Zn). Basic data were obtained with this detector system for later studies.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A theoretical and experimental research on detection efficiency of HPGe detector for disc source with heterogeneous distribution
    Zi-ning Tian
    Xiao-ping Ouyang
    Lin-yue Liu
    Jin-lu Ruan
    Jin-liang Liu
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 304 : 905 - 910
  • [32] Research on detection efficiency of hpge detector without standard source calibration in carr laboratory
    Zhang N.-P.
    Ding L.
    1600, Atomic Energy Press (51): : 2326 - 2329
  • [33] A theoretical and experimental research on detection efficiency of HPGe detector for disc source with heterogeneous distribution
    Tian, Zi-ning
    Ouyang, Xiao-ping
    Liu, Lin-yue
    Ruan, Jin-lu
    Liu, Jin-liang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 304 (02) : 905 - 910
  • [34] Investigating the Impact of Source Geometry and Distance on HPGe Detector Efficiency Using MCNPX Simulations
    Rastgoo, Mazaher
    Sadremomtaz, Alireza
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (12):
  • [35] Natural radium isotopes in waters determined with gamma-ray spectrometry using a HPGe detector
    Patricio, Marta L. V.
    Bonotto, Daniel M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 327 (01) : 403 - 416
  • [36] Natural radium isotopes in waters determined with gamma-ray spectrometry using a HPGe detector
    Marta L. V. Patricio
    Daniel M. Bonotto
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 327 : 403 - 416
  • [37] THE RESPONSE OF A HPGE DETECTOR WITH A BGO SHIELD TO HIGH-ENERGY GAMMA-RAYS
    CAMERA, F
    BRACCO, A
    MATTIUZZI, M
    LOBIANCO, G
    PIGNANELLI, M
    GAARDHOJE, JJ
    BEARDEN, IG
    ZELAZNY, Z
    MAJ, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 351 (2-3): : 401 - 405
  • [38] METHOD TO EVALUATE THE DEPENDENCE OF GE(LI) SPECTROMETERS EFFICIENCY SLOPES ON THE COUNTING RATE AND SOURCE-TO-DETECTOR DISTANCE
    LEILA, HA
    ISMAIL, HA
    KAMEL, M
    ELASHRY, M
    ATOMKERNENERGIE-KERNTECHNIK, 1979, 33 (01): : 50 - 51
  • [39] METHOD TO EVALUATE THE DEPENDENCE OF GE(LI) SPECTROMETERS EFFICIENCY SLOPES ON THE COUNTING RATE AND SOURCE-TO-DETECTOR DISTANCE
    LEILA, HA
    ISMAIL, HA
    KAMEL, M
    ELASHRY, M
    DARWISH, SM
    ATOMKERNENERGIE, 1979, 33 (01): : 50 - 51
  • [40] HPGe detector full-energy peak efficiency calculation for inhomogeneously activated samples
    Lojze Gačnik
    Radojko Jaćimović
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 311 : 1315 - 1321