Efficiency and energy resolution of gamma spectrometry system with HPGe detector depending on variable source-to-detector distances

被引:3
|
作者
Hafizoglu, Nurgul [1 ]
机构
[1] Istanbul Univ, Fac Sci, Dept Phys, TR-34134 Vezneciler, Istanbul, Turkiye
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2024年 / 139卷 / 02期
关键词
CALIBRATION;
D O I
10.1140/epjp/s13360-024-04903-y
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The high-purity germanium (HPGe) detectors, which are one of the basic instruments in the experimental nuclear physics, are widely used in many areas such as the environmental radioactivity, neutron activation analysis and geology. This study reports the results of energy calibration, energy resolution and efficiency calculations for an HPGe detector (ORTEC), which are necessary to determine the quality of the measurement results obtained from a gamma spectrometry system. For the purpose of examining the effects of gamma-ray energy and the distance between the source and the detector on the detector efficiency, measurements were made at six different source-detector distances for a total of about fourteen energies of the point sources (133Ba, 109Cd, 137Cs, 57Co, 60Co, 152Eu, 22Na, and 65Zn). Basic data were obtained with this detector system for later studies.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Empirical formula for the HPGe-detector efficiency dependence on energy and distance
    I. Pylypchynets
    A. Lengyel
    O. Parlag
    V. Maslyuk
    I. Potoki
    Journal of Radioanalytical and Nuclear Chemistry, 2019, 319 : 1315 - 1319
  • [22] Two-effective-source method for the calculation of in-air output at various source-to-detector distances in wedged fields
    Kim, SY
    Liu, CR
    Chen, C
    Palta, JR
    MEDICAL PHYSICS, 1999, 26 (06) : 949 - 955
  • [23] Establishment of HPGe detector efficiency for point source including true coincidence correction
    El-Gharbawy, HA
    Metwally, SM
    Sharshar, T
    Elnimr, T
    Badran, HM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 550 (1-2): : 201 - 211
  • [24] Design of simulation gas calibration source for calibrating peak efficiency of HPGe detector
    Wang, Shi-Lian
    Li, Qi
    Fan, Yuan-Qing
    Liu, Shu-Jiang
    Chang, Yin-Zhong
    Jia, Huai-Mao
    Chen, Zhan-Ying
    Zhang, Xin-Jun
    Wang, Jun
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (07): : 773 - 777
  • [25] Efficiency calibration of HPGe detector in a PGNAA system for the measurement of aqueous samples
    Cheng, Can
    Jia, Wenbao
    Hei, Daqian
    Li, Jiatong
    Cai, Pingkun
    Zhao, Dong
    Wei, Zhiyong
    APPLIED RADIATION AND ISOTOPES, 2019, 145 : 1 - 6
  • [26] EMPIRICAL FORMULA FOR THE DEPENDENCE OF HPGe-DETECTOR EFFICIENCY ON ENERGY AND DISTANCE FOR SHIELDED GAMMA-RAY SOURCES
    Pylypchynets, I. V.
    Lengyel, O. I.
    Parlag, O. O.
    Oleynikov, E. V.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2023, (03): : 47 - 51
  • [27] Efficiency calibrations of radiation detectors for source localization and characterization at long source-detector distances for gamma and neutron sources
    Toivonen, Harri
    Dowdall, Mark
    Baron, Martin
    Kroeger, Emily
    APPLIED RADIATION AND ISOTOPES, 2023, 198
  • [28] Accurate efficiency calibration of a low-energy HPGe detector using a monochromatic x-ray source
    Plagnard, Johann
    Bobin, Christophe
    Lepy, Marie-Christine
    X-RAY SPECTROMETRY, 2007, 36 (03) : 191 - 198
  • [29] Full energy peak efficiency of a clover detector in direct and add-back modes at different source to detector distances: a comparative study
    Gupta, Ashish
    Shareef, M.
    Twisha, Munmun
    Bhattacharjee, Saikat
    Mukherjee, A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2025,
  • [30] The limit of SiC detector energy resolution in ion spectrometry
    Yakimova, R.
    Lebedev, A. A.
    Ivanov, A. M.
    Strokan, N. B.
    Syvajarvi, M.
    SILICON CARBIDE AND RELATED MATERIALS 2005, PTS 1 AND 2, 2006, 527-529 : 1477 - 1480