Investigating the Impact of Source Geometry and Distance on HPGe Detector Efficiency Using MCNPX Simulations

被引:0
|
作者
Rastgoo, Mazaher [1 ]
Sadremomtaz, Alireza [2 ]
机构
[1] Univ Guilan, Dept Phys, Univ Campus, Rasht, Iran
[2] Univ Guilan, Fac Sci, Dept Phys, Rasht, Iran
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2024年 / 139卷 / 12期
关键词
CALIBRATION; POINT; CODE;
D O I
10.1140/epjp/s13360-024-05891-9
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The most important characteristic of HPGe detector is its efficiency, which depends on the geometry of the source and the detector material. Normally, efficiency is function of the gamma energy and must be determined for each specific material that is subject of the measurements. This requires secondary standard for each material, and it is expensive and time-consuming process. Monte Carlo method can be helpful as an alternative computational method to calculate the efficiency of HPGe detector. This paper describes a procedure for constructing a Monte Carlo model of an HPGe detector used to measure activity. In this work, the HPGe detector was completely simulated by MCNPX computational code according to the laboratory conditions and geometry of the Marinelli source. Comparison has shown the average difference of about 10% between the experimental and the Monte Carlo simulation efficiency of the HPGe detector. The detector efficiency for the source in cylindrical geometry with various dimensions and different distances between the source and the detector was calculated and studied.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Characterizing the coaxial HPGe detector using Monte Carlo simulations and evolutionary algorithms
    Prozorova, Irina, V
    Ghal-Eh, Nima
    Bedenko, Sergey, V
    Popov, Yury A.
    Prozorov, Andrey A.
    Vega-Carrillo, Hector R.
    APPLIED RADIATION AND ISOTOPES, 2021, 174
  • [32] Estimation of background spectrum in a shielded HPGe detector using Monte Carlo simulations
    Medhat, M. E.
    Wang, Yifang
    APPLIED RADIATION AND ISOTOPES, 2014, 84 : 13 - 18
  • [33] EFFICIENCY CALIBRATION OF A GE(LI) DETECTOR AT SHORT SOURCE-TO-DETECTOR DISTANCE
    KAWADE, K
    EZUKA, M
    YAMAMOTO, H
    SUGIOKA, K
    KATOH, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 190 (01): : 101 - 106
  • [34] Precise determination of HPGe detector efficiency for gamma spectrometry measurements of environmental samples with variable geometry and density
    Barrera, Manuel
    Casas-Ruiz, Melquiades
    Alonso, Jose J.
    Vidal, Juan
    NUKLEONIKA, 2017, 62 (01) : 47 - 59
  • [35] Efficiency Application of Monte Carlo Simulation and HPGe Detector Using Mapping Method
    Jang, Eun-Sung
    Chang, Bo-Seok
    JOURNAL OF MAGNETICS, 2024, 29 (02)
  • [36] HPGE DETECTOR ABSOLUTE-PEAK-EFFICIENCY CALIBRATION BY USING THE ESOLAN PROGRAM
    WANG, TK
    MAR, WY
    YING, TH
    LIAO, CH
    TSENG, CL
    APPLIED RADIATION AND ISOTOPES, 1995, 46 (09) : 933 - 944
  • [37] Germanium detector efficiency for a Marinelli beaker source-geometry using the Monte Carlo method
    Ewa, IOB
    Bodizs, D
    Czifrus, S
    Balla, M
    Molnar, Z
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2002, 20 (02): : 161 - 170
  • [38] Using Monte Carlo Simulations and Experimental Measurements to Calibrate An HPGE Gamma Detector Precisely
    Zhai, Yongjun
    Trache, Livius
    Tribble, Robert
    Papanikolaou, Nikos
    Liu, Yaxi
    Shi, Chengyu
    Iacob, Victor
    Hardy, John
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2009, 32 (01): : 105 - 106
  • [39] Study of the response of an ORTEC GMX45 HPGe detector with a multi-radionuclide volume source using Monte Carlo simulations
    Saraiva, A.
    Oliveira, C.
    Reis, M.
    Portugal, L.
    Paiva, I.
    Cruz, C.
    APPLIED RADIATION AND ISOTOPES, 2016, 113 : 47 - 52
  • [40] Investigating the practicality of a minimally defined co-axial HPGe detector model using MCNP
    Goodell, John J.
    Roberts, Kevin E.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 322 (03) : 1965 - 1973