Characterization of a pediatric rotary blood pump

被引:2
|
作者
de Melo T.R. [1 ]
Vasconcelos F.J.S. [1 ]
Ribeiro L.H.R.D. [1 ]
Bacht S. [2 ]
Cestari I.A. [2 ]
Neto J.S.D.R. [1 ]
Lima A.M.N. [1 ]
机构
[1] Federal University of Campina Grande, Campina Grande, PB
[2] Bioengineering Division, Heart Institute, São Paulo, SP
基金
巴西圣保罗研究基金会;
关键词
Centrifugal flow pump; Lumped parameter model; Rotary blood pump; System identification; Ventricular assist device;
D O I
10.1590/2446-4740.180046
中图分类号
学科分类号
摘要
Introduction: A ventricular assist device (VAD) is an electromechanical pump used to treat heart failures. For designing the physiological control system for a VAD, one needs a mathematical model and its related parameters. This paper presents a characterization procedure for determining the model parameter values of the electrical, mechanical, and hydraulic subsystems of a pediatric Rotary Blood Pump (pRBP). Methods: An in vitro test setup consisting of a pRBP prototype, a motor driver module, an acrylic reservoir, mechanical resistance and tubings, pressure and fluid flow sensors, and data acquisition, processing, and visualization system. The proposed procedure requires a set of experimental tests, and a parameter estimation algorithm for determining the model parameters values. Results: The operating limits of the pRBP were identified from the steady-state data. The relationship between the pressure head, flow rate, and the rotational speed of the pRBP was found from the static tests. For the electrical and mechanical subsystems, the dc motor model has a viscous friction coefficient that varies nonlinearly with the flow. For the hydraulic subsystem, the pressure head is assumed to be a sum of terms related to the resistance, the inertance, the friction coefficient, and the pump speed. Conclusion: The proposed methodology was successfully applied to the characterization of the pRBP. The combined use of static and dynamic tests provided a precise lumped parameter model for representing the pRBP dynamics. The agreement, regarding mean squared deviation, between experimental and simulated results demonstrates the correctness and feasibility of the characterization procedure. © 2018, Brazilian Society of Biomedical Engineering. All rights reserved.
引用
收藏
页码:299 / 309
页数:10
相关论文
共 50 条
  • [1] The Progress in the Novel Pediatric Rotary Blood Pump Sputnik Development
    Telyshev, Dmitry
    Denisov, Maxim
    Pugovkin, Alexander
    Selishchev, Sergey
    Nesterenko, Igor
    ARTIFICIAL ORGANS, 2018, 42 (04) : 432 - 443
  • [2] Design and Computational Evaluation of a Pediatric MagLev Rotary Blood Pump
    Tompkins, Landon H.
    Gellman, Barry N.
    Morello, Gino F.
    Prina, Steven R.
    Roussel, Thomas J.
    Kopechek, Jonathan A.
    Petit, Priscilla C.
    Slaughter, Mark S.
    Koenig, Steven C.
    Dasse, Kurt A.
    ASAIO JOURNAL, 2021, 67 (09) : 1026 - 1035
  • [3] Computational Fluid Dynamics Simulation of the Sputnik Pediatric Rotary Blood Pump
    Telyshev, Dmitry
    Denisov, Maxim
    Satyukova, Anna
    Le, Tatyana
    PROCEEDINGS OF 2018 IEEE EAST-WEST DESIGN & TEST SYMPOSIUM (EWDTS 2018), 2018,
  • [4] Blood transfusion with rotary pump
    Darmady, EM
    BRITISH MEDICAL JOURNAL, 1939, 1939 : 1304 - 1305
  • [5] Blood transfusion with the rotary pump
    Riddell, V
    BRITISH MEDICAL JOURNAL, 1939, 1939 : 1125 - 1129
  • [6] Modeling of a Rotary Blood Pump
    Nestler, Frank
    Bradley, Andrew P.
    Wilson, Stephen J.
    Timms, Daniel L.
    ARTIFICIAL ORGANS, 2014, 38 (03) : 182 - 190
  • [7] Experimental Determination of the Normalized Index of Hemolysis for the Sputnik Implantable Pediatric Rotary Blood Pump
    Bockeria L.A.
    Bockeria O.L.
    Selishchev S.V.
    Telyshev D.V.
    Le T.G.
    Satyukova A.S.
    Shvartz V.A.
    Glushko L.A.
    Biomedical Engineering, 2017, 50 (6) : 416 - 419
  • [8] Control system for an rotary blood pump
    Nakata, K.
    Shiono, M.
    Orime, Y.
    Yagi, S.
    Yamamoto, T.
    Okumura, H.
    Kashiwazaki, A.
    Choh, S.
    Hirose, H.
    Saito, A.
    Taniguchi, T.
    Negishi, N.
    Sezai, Y.
    Sankai, Y.
    Fujisawa, A.
    Makinouchi, K.
    Yokokawa, M.
    ASAIO Journal, 2000, 46 (02)
  • [9] A novel rotary blood pump for HFpEF
    Gude, E.
    Fiane, D. R.
    EUROPEAN JOURNAL OF HEART FAILURE, 2019, 21 : 348 - 348
  • [10] A Novel Rotary Blood Pump for HFpEF
    Gude, E.
    Fiane, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S342 - S342