Design and Computational Evaluation of a Pediatric MagLev Rotary Blood Pump

被引:9
|
作者
Tompkins, Landon H. [1 ]
Gellman, Barry N. [2 ]
Morello, Gino F. [3 ]
Prina, Steven R. [4 ]
Roussel, Thomas J. [1 ]
Kopechek, Jonathan A. [1 ]
Petit, Priscilla C. [2 ]
Slaughter, Mark S. [5 ]
Koenig, Steven C. [1 ,5 ]
Dasse, Kurt A. [1 ,2 ,5 ]
机构
[1] Univ Louisville, Dept Bioengn, Louisville, KY 40202 USA
[2] Inspired Therapeut LLC, 125 E Merritt Isl Cswy,107-341, Merritt Isl, FL 32925 USA
[3] Veritium Res LLC, Ft Lee, NJ USA
[4] BLDC Designs LLC, Rocklin, CA USA
[5] Univ Louisville, Dept Cardiovasc & Thorac Surg, Louisville, KY 40202 USA
基金
美国国家卫生研究院;
关键词
mechanical circulatory support; ventricular assist device; computational fluid dynamics; pediatric; centrifugal pump; VENTRICULAR ASSIST DEVICES; CIRCULATORY SUPPORT; CONTINUOUS-FLOW; FLUID-DYNAMICS; UNITED-STATES;
D O I
10.1097/MAT.0000000000001323
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pediatric heart failure (HF) patients have been a historically underserved population for mechanical circulatory support (MCS) therapy. To address this clinical need, we are developing a low cost, universal magnetically levitated extracorporeal system with interchangeable pump heads for pediatric support. Two impeller and pump designs (pump V1 and V2) for the pediatric pump were developed using dimensional analysis techniques and classic pump theory based on defined performance criteria (generated flow, pressure, and impeller diameter). The designs were virtually constructed using computer-aided design (CAD) software and 3D flow and pressure features were analyzed using computational fluid dynamics (CFD) analysis. Simulated pump designs (V1, V2) were operated at higher rotational speeds (similar to 5,000 revolutions per minute [RPM]) than initially estimated (4,255 RPM) to achieve the desired operational point (3.5 L/min flow at 150 mm Hg). Pump V2 outperformed V1 by generating approximately 30% higher pressures at all simulated rotational speeds and at 5% lower priming volume. Simulated hydrodynamic performance (achieved flow and pressure, hydraulic efficiency) of our pediatric pump design, featuring reduced impeller size and priming volume, compares favorably to current commercially available MCS devices.
引用
收藏
页码:1026 / 1035
页数:10
相关论文
共 50 条
  • [1] EVALUATION OF THE MAGLEV MOTOR AND DESIGN OF THE CENTRIFUGAL BLOOD PUMP FOR PEDIATRIC ARTIFICIAL HEART
    Osa, M.
    Masuzawa, T.
    Tatsumi, E.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 609 - 609
  • [2] Computational Fluid Dynamics Simulation of the Sputnik Pediatric Rotary Blood Pump
    Telyshev, Dmitry
    Denisov, Maxim
    Satyukova, Anna
    Le, Tatyana
    [J]. PROCEEDINGS OF 2018 IEEE EAST-WEST DESIGN & TEST SYMPOSIUM (EWDTS 2018), 2018,
  • [4] COMPUTATIONAL FLOW OPTIMIZATION OF ROTARY BLOOD PUMP COMPONENTS
    ANTAKI, JF
    GHATTAS, O
    BURGREEN, GW
    HE, BC
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 608 - 615
  • [5] A two-stage rotary blood pump design with potentially lower blood trauma: a computational study
    Thamsen, Bente
    Mevert, Ricardo
    Lommel, Michael
    Preikschat, Philip
    Gaebler, Julia
    Krabatsch, Thomas
    Kertzscher, Ulrich
    Hennig, Ewald
    Affeld, Klaus
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2016, 39 (04): : 178 - 183
  • [6] Effects of the Design of a Rotary Blood Pump on Hemocompatibility
    M. V. Denisov
    M. Walter
    S. Leonhard
    D. V. Telyshev
    [J]. Biomedical Engineering, 2021, 54 : 327 - 332
  • [7] Effects of the Design of a Rotary Blood Pump on Hemocompatibility
    Denisov, M., V
    Walter, M.
    Leonhard, S.
    Telyshev, D., V
    [J]. BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2021, 54 (05): : 327 - 332
  • [8] Design and development strategy for the rotary blood pump
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1998, 22 (06) : 438 - 446
  • [9] Computational Design and In Vitro Characterization of an Integrated Maglev Pump-Oxygenator
    Zhang, Juntao
    Taskin, M. Ertan
    Koert, Andrew
    Zhang, Tao
    Gellman, Barry
    Dasse, Kurt A.
    Gilbert, Richard J.
    Griffith, Bartley P.
    Wu, Zhongjun J.
    [J]. ARTIFICIAL ORGANS, 2009, 33 (10) : 805 - 817
  • [10] Hemolytic performance of a MagLev disposable rotary blood pump (MedTech Dispo): Effects of MagLev gap clearance and surface roughness
    Hoshi, Hideo
    Asama, Junichi
    Hijikata, Wataru
    Hara, Chikara
    Shinshi, Tadahiko
    Yasuda, Toshitaka
    Ohuchi, Katsuhiro
    Shimokohbe, Akira
    Takatani, Setsuo
    [J]. ARTIFICIAL ORGANS, 2006, 30 (12) : 949 - 954