摘要
Development of an antitraumatic antithrombogenic and durable blood pump is a very difficult task. Based upon this author's experience of over 35 years in the development of various types of cardiac prostheses, development strategies for a rotary blood pump are described. A step-by-step development strategy is thus proposed. Initially, the development of a 2 day antitraumatic pump (Phase 1) would be made. Then, conversion of this pump to a 2 week antithrombogenic pump (Phase 2) should be attempted. After the successful development of the Phase 2 pump, the conversion of this device to a durable, implantable, and long-term blood pump (Phase 3) should be established. Based upon this development strategy, 2 rotary blood pumps, namely, the axial Row blood pump and the centrifugal blood pump, have been developed in less than 4 pears with modest development costs.
引用
收藏
页码:438 / 446
页数:9
相关论文
共 50 条
  • [1] A rotary blood pump: Its design and development strategy
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1997, 21 (04) : 263 - 264
  • [2] Effects of the Design of a Rotary Blood Pump on Hemocompatibility
    M. V. Denisov
    M. Walter
    S. Leonhard
    D. V. Telyshev
    [J]. Biomedical Engineering, 2021, 54 : 327 - 332
  • [3] Effects of the Design of a Rotary Blood Pump on Hemocompatibility
    Denisov, M., V
    Walter, M.
    Leonhard, S.
    Telyshev, D., V
    [J]. BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2021, 54 (05): : 327 - 332
  • [4] Pitfalls in the development of a rotary blood pump controller
    Konishi, H
    Misawa, Y
    Fuse, K
    Sohara, Y
    [J]. ASAIO JOURNAL, 2001, 47 (04) : 397 - 400
  • [5] Development of Pressure Estimation for External Rotary Blood Pump
    Diloksumpan, Paweena
    Naiyanetr, Phornphop
    [J]. 6TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2013), 2013,
  • [6] Rotary Blood Pump Control Strategy for Preventing Left Ventricular Suction
    Wang, Yu
    Koenig, Steven C.
    Slaughter, Mark S.
    Giridharan, Guruprasad A.
    [J]. ASAIO JOURNAL, 2015, 61 (01) : 21 - 30
  • [7] EFFECT OF INFLOW CANNULA ON ROTARY BLOOD PUMP SPEED PULSING STRATEGY
    Wong, K. C.
    Timms, D. L.
    Steinseifer, U.
    Schmitz-Rode, T.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 613 - 613
  • [9] A FLUID DYNAMIC ANALYSIS OF A ROTARY BLOOD PUMP FOR DESIGN IMPROVEMENT
    TREICHLER, J
    ROSENOW, SE
    DAMM, G
    NAITO, K
    OHARA, Y
    MIZUGUCHI, K
    MAKINOUCHI, K
    TAKATANI, S
    NOSE, Y
    [J]. ARTIFICIAL ORGANS, 1993, 17 (09) : 797 - 808
  • [10] Design and Computational Evaluation of a Pediatric MagLev Rotary Blood Pump
    Tompkins, Landon H.
    Gellman, Barry N.
    Morello, Gino F.
    Prina, Steven R.
    Roussel, Thomas J.
    Kopechek, Jonathan A.
    Petit, Priscilla C.
    Slaughter, Mark S.
    Koenig, Steven C.
    Dasse, Kurt A.
    [J]. ASAIO JOURNAL, 2021, 67 (09) : 1026 - 1035