Pitfalls in the development of a rotary blood pump controller

被引:9
|
作者
Konishi, H [1 ]
Misawa, Y [1 ]
Fuse, K [1 ]
Sohara, Y [1 ]
机构
[1] Jichi Med Sch, Dept Thorac & Cardiovasc Surg, Kawachi, Tochigi 3290498, Japan
关键词
D O I
10.1097/00002480-200107000-00019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The controller presents a major obstacle in the development of the rotary blood pump as a left ventricular assist device (LVAD). Clinically, LVAD flow is a good indicator in the regulation of circulatory conditions and pump flow changes, depending on pump preload and afterload. Many investigators have tried estimating pump flow by referencing the motor current. There have been pitfalls in in vitro experimental settings, however. Using a test loop with a pneumatically driven LV chamber and a centrifugal pump as an LVAD, we monitored pump flow and pressure head to evaluate the pump performance curve (H-Q curve). Under pulsatile LV conditions, the H-Q curve was a loop that changed, depending on LV contractility. The pneumatically driven LV chamber cannot mimic the Starling phenomenon, so the developed LV pressure does not change according to the LV preload. Rotary pump flow estimation is the most effective control method. in pulsatile conditions, however, the H-Q curve is a loop that changes under various LV contractility conditions, complicating determination of linear equation for calculating flow. In addition, the LV chamber in the test loop cannot mimic native heart contractility as described by Starling's law. This finding can lead to a misanalysis of the H-Q curve under pulsatile conditions.
引用
收藏
页码:397 / 400
页数:4
相关论文
共 50 条
  • [1] Preload Based ADRC Physiological Controller for Rotary Blood Pump
    Wu, Yi
    Zheng, Qing
    Lim, Einly
    [J]. PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 9428 - 9433
  • [2] Design and development strategy for the rotary blood pump
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1998, 22 (06) : 438 - 446
  • [3] A fuzzy system cardio pulmonary bypass rotary blood pump controller
    Casas, F
    Orozco, A
    Smith, WA
    De Abreu-García, JA
    Durkin, J
    [J]. EXPERT SYSTEMS WITH APPLICATIONS, 2004, 26 (03) : 357 - 361
  • [4] A rotary blood pump: Its design and development strategy
    Nose, Y
    [J]. ARTIFICIAL ORGANS, 1997, 21 (04) : 263 - 264
  • [5] Development of Pressure Estimation for External Rotary Blood Pump
    Diloksumpan, Paweena
    Naiyanetr, Phornphop
    [J]. 6TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2013), 2013,
  • [6] In Silico Evaluation of a Physiological Controller for a Rotary Blood Pump Based on a Sensorless Estimator
    Bakouri, Mohsen
    Alassaf, Ahmad
    Alshareef, Khaled
    AlMohimeed, Ibrahim
    Alqahtani, Abdulrahman
    Aboamer, Mohamed Abdelkader
    Alonazi, Khalid A.
    Alharbi, Yousef
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (22):
  • [7] The Progress in the Novel Pediatric Rotary Blood Pump Sputnik Development
    Telyshev, Dmitry
    Denisov, Maxim
    Pugovkin, Alexander
    Selishchev, Sergey
    Nesterenko, Igor
    [J]. ARTIFICIAL ORGANS, 2018, 42 (04) : 432 - 443
  • [8] Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump
    Göbel, C
    Arvand, A
    Eilers, R
    Marseille, O
    Bals, C
    Meyns, B
    Flameng, W
    Rau, G
    Reul, H
    [J]. ARTIFICIAL ORGANS, 2001, 25 (05) : 358 - 365
  • [9] Development of a non-pulsatile permanent rotary blood pump
    Nose, Y
    Kawahito, K
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 : S32 - S38
  • [10] Development of rotary blood pump technology:: Past, present, and future
    Nosé, Y
    Yoshikawa, M
    Murabayashi, S
    Takano, T
    [J]. ARTIFICIAL ORGANS, 2000, 24 (06) : 412 - 420