A fuzzy system cardio pulmonary bypass rotary blood pump controller

被引:15
|
作者
Casas, F
Orozco, A
Smith, WA
De Abreu-García, JA
Durkin, J
机构
[1] Cleveland Clin Fdn, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44195 USA
[2] Univ Akron, Dept Elect & Comp Engn, Akron, OH 44325 USA
关键词
rotary blood pump; fuzzy control; non-linear model; flow estimation;
D O I
10.1016/j.eswa.2003.09.006
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Fuzzy logic regulation of flow was investigated in simulation of a model of the Cleveland Clinic Foundation rotodynamic Cardio Pulmonary Bypass blood pump comprised of impeller model #4079 and volute model #4080. A non-linear model of the pump was derived from pump maps obtained from measurements using a custom made pump dynamometer. Pump speed and generated delta pressure were used as inputs to a fuzzy engine in charge of manipulating the pump's speed; the fuzzy controller was capable of maintaining a setpoint of 6 +/- 0.5 l/min when presented with pressure disturbances over a range of +/- 50 mmHg from the baseline of 100 mmHg. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:357 / 361
页数:5
相关论文
共 50 条
  • [1] Fuzzy logic control of a cardio pulmonary bypass rotary blood pump
    Berrón, C
    De Abreu-Garcia, JA
    [J]. PROCEEDINGS OF THE THIRD IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2005, : 260 - 264
  • [2] Pitfalls in the development of a rotary blood pump controller
    Konishi, H
    Misawa, Y
    Fuse, K
    Sohara, Y
    [J]. ASAIO JOURNAL, 2001, 47 (04) : 397 - 400
  • [3] Successful use of a miniaturized bypass system with the DeltaStream extracorporeal rotary blood pump
    Christiansen, S
    Göbel, C
    Buhre, W
    Reul, H
    Autschbach, R
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (01): : 43 - 44
  • [4] Preliminary evaluation of a predictive controller for a rotary blood pump based on pulmonary oxygen gas exchange
    Huang, Feng
    Gou, Zhe
    Fu, Yang
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (02) : 267 - 278
  • [5] Preload Based ADRC Physiological Controller for Rotary Blood Pump
    Wu, Yi
    Zheng, Qing
    Lim, Einly
    [J]. PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 9428 - 9433
  • [6] EXPERIMENTAL USE OF A SEMIPULSATILE ROTARY BLOOD PUMP FOR CARDIOPULMONARY BYPASS
    MESANA, T
    MORITA, S
    TRINKL, J
    DEMUNCK, JL
    GAUTHIER, T
    AUCOMTE, F
    HAVLIK, P
    MONTIES, JR
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 734 - 738
  • [7] Role of pump prime in the etiology of cardio-pulmonary bypass associated acidosis
    Sanjay O.P.
    Kilpadi K.
    [J]. Indian Journal of Clinical Biochemistry, 2002, 17 (1) : 42 - 44
  • [8] Design and Implementation of Fuzzy Logic Controller for Peristaltic Blood Pump
    Busono, Pratondo
    [J]. INTERNATIONAL CONFERENCE ON INFORMATICS, CONTROL AND AUTOMATION (ICA 2015), 2015, : 270 - 274
  • [9] DEVELOPMENT AND EVALUATION OF A NEW PULSATILE VENTRICLE PUMP FOR USE IN CARDIO-PULMONARY BYPASS
    BIVONA, JC
    BENTLEY, DJ
    SAWYER, PN
    [J]. CIRCULATION, 1971, 44 (04) : 142 - &
  • [10] In Silico Evaluation of a Physiological Controller for a Rotary Blood Pump Based on a Sensorless Estimator
    Bakouri, Mohsen
    Alassaf, Ahmad
    Alshareef, Khaled
    AlMohimeed, Ibrahim
    Alqahtani, Abdulrahman
    Aboamer, Mohamed Abdelkader
    Alonazi, Khalid A.
    Alharbi, Yousef
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (22):