Design and development strategy for the rotary blood pump

被引:54
|
作者
Nose, Y [1 ]
机构
[1] Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
关键词
development strategy of blood pump; rotary blood pump; axial flow pump; centrifugal blood pump; 2 day pump; 2 week pump; permanent pump;
D O I
10.1046/j.1525-1594.1998.06098.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Development of an antitraumatic antithrombogenic and durable blood pump is a very difficult task. Based upon this author's experience of over 35 years in the development of various types of cardiac prostheses, development strategies for a rotary blood pump are described. A step-by-step development strategy is thus proposed. Initially, the development of a 2 day antitraumatic pump (Phase 1) would be made. Then, conversion of this pump to a 2 week antithrombogenic pump (Phase 2) should be attempted. After the successful development of the Phase 2 pump, the conversion of this device to a durable, implantable, and long-term blood pump (Phase 3) should be established. Based upon this development strategy, 2 rotary blood pumps, namely, the axial Row blood pump and the centrifugal blood pump, have been developed in less than 4 pears with modest development costs.
引用
收藏
页码:438 / 446
页数:9
相关论文
共 50 条
  • [31] A Novel Design of Spiral Groove Bearing in a Hydrodynamically Levitated Centrifugal Rotary Blood Pump
    Han, Qing
    Zou, Jun
    Ruan, Xiaodong
    Fu, Xin
    Yang, Huayong
    [J]. ARTIFICIAL ORGANS, 2012, 36 (08) : 739 - 746
  • [32] Rotary blood pump: Paracorporeal, implantable, percutaneous?
    Nishida, H
    Koyanagi, K
    [J]. ARTIFICIAL ORGANS, 1997, 21 (07) : 589 - 591
  • [33] Daily Activity in Rotary Blood Pump Recipients
    Granegger, M.
    Schloeglhofer, T.
    Ober, H.
    Riebandt, J.
    Zimpfer, D.
    Schima, H.
    Moscato, F.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S220 - S220
  • [34] Development of a control algorithm for a rotary blood pump - Prediction of recovery from cardiac failure
    Konishi, H
    Misawa, Y
    Fuse, K
    [J]. ASAIO JOURNAL, 1998, 44 (05) : M449 - M451
  • [35] Control strategy for rotary blood pumps
    Ohuchi, K
    Kikugawa, D
    Takahashi, K
    Uemura, M
    Nakamura, M
    Murakami, T
    Sakamoto, T
    Takatani, S
    [J]. ARTIFICIAL ORGANS, 2001, 25 (05) : 366 - 370
  • [36] Development of a Pump Flow Estimator for Rotary Blood Pumps to Enhance Monitoring of Ventricular Function
    Granegger, Marcus
    Moscato, Francesco
    Casas, Fernando
    Wieselthaler, Georg
    Schima, Heinrich
    [J]. ARTIFICIAL ORGANS, 2012, 36 (08) : 691 - 699
  • [37] SAFETY AWARE PUMP-CONTROL FOR A ROTARY ECMO BLOOD PUMP
    Stollenwerk, A.
    Gathmann, F.
    Arens, J.
    Bensberg, R.
    Walter, M.
    Kopp, R.
    Kowalewski, S.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 617 - 617
  • [38] DESIGN ANALYSIS OF AN EPICYCLIC ROTARY PUMP MECHANISM
    SADLER, JP
    NELLE, DE
    [J]. JOURNAL OF MECHANICAL DESIGN-TRANSACTIONS OF THE ASME, 1979, 101 (01): : 99 - 107
  • [39] Design optimization of a synchronal rotary multiphase pump
    Yang, Xu
    Zhang, Jiang
    Hu, Xu
    Qu, Zongchang
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2016, 230 (02) : 134 - 145
  • [40] Performance and development of a miniature rotary shaft pump
    Blanchard, D
    Ligrani, P
    Gale, B
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (04): : 752 - 760