Characterization of a pediatric rotary blood pump

被引:2
|
作者
de Melo T.R. [1 ]
Vasconcelos F.J.S. [1 ]
Ribeiro L.H.R.D. [1 ]
Bacht S. [2 ]
Cestari I.A. [2 ]
Neto J.S.D.R. [1 ]
Lima A.M.N. [1 ]
机构
[1] Federal University of Campina Grande, Campina Grande, PB
[2] Bioengineering Division, Heart Institute, São Paulo, SP
基金
巴西圣保罗研究基金会;
关键词
Centrifugal flow pump; Lumped parameter model; Rotary blood pump; System identification; Ventricular assist device;
D O I
10.1590/2446-4740.180046
中图分类号
学科分类号
摘要
Introduction: A ventricular assist device (VAD) is an electromechanical pump used to treat heart failures. For designing the physiological control system for a VAD, one needs a mathematical model and its related parameters. This paper presents a characterization procedure for determining the model parameter values of the electrical, mechanical, and hydraulic subsystems of a pediatric Rotary Blood Pump (pRBP). Methods: An in vitro test setup consisting of a pRBP prototype, a motor driver module, an acrylic reservoir, mechanical resistance and tubings, pressure and fluid flow sensors, and data acquisition, processing, and visualization system. The proposed procedure requires a set of experimental tests, and a parameter estimation algorithm for determining the model parameters values. Results: The operating limits of the pRBP were identified from the steady-state data. The relationship between the pressure head, flow rate, and the rotational speed of the pRBP was found from the static tests. For the electrical and mechanical subsystems, the dc motor model has a viscous friction coefficient that varies nonlinearly with the flow. For the hydraulic subsystem, the pressure head is assumed to be a sum of terms related to the resistance, the inertance, the friction coefficient, and the pump speed. Conclusion: The proposed methodology was successfully applied to the characterization of the pRBP. The combined use of static and dynamic tests provided a precise lumped parameter model for representing the pRBP dynamics. The agreement, regarding mean squared deviation, between experimental and simulated results demonstrates the correctness and feasibility of the characterization procedure. © 2018, Brazilian Society of Biomedical Engineering. All rights reserved.
引用
收藏
页码:299 / 309
页数:10
相关论文
共 50 条
  • [31] Bearing dynamic characteristics of the ventrassist rotary blood pump
    Chung, M
    Zhang, N
    Tansley, GD
    Woodard, JC
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON VIBRATION ENGINEERING, 2002, : 155 - 161
  • [32] High efficiency magnetic bearing for a rotary blood pump
    Chen, H. Ming
    Smith, William A.
    Walton, James F.
    ASAIO Journal, 44 (05):
  • [33] Evaluation of hemolysis in the VentrAssist implantable rotary blood pump
    James, NL
    Wilkinson, CM
    Lingard, NL
    van der Meer, AL
    Woodard, JC
    ARTIFICIAL ORGANS, 2003, 27 (01) : 108 - 113
  • [34] In vitro analysis of the flow fields of a rotary blood pump
    Morsi, Y
    Yang, W
    Chan, S
    COMPUTATIONAL MECHANICS, VOLS 1 AND 2, PROCEEDINGS: NEW FRONTIERS FOR THE NEW MILLENNIUM, 2001, : 875 - 880
  • [35] The rotary blood pump: Lessons learned and future directions
    DeBakey, ME
    Noon, GP
    Teitel, ER
    ARTIFICIAL ORGANS, 2004, 28 (10) : 865 - 868
  • [36] Experimental and Numerical Investigation of an Axial Rotary Blood Pump
    Schuele, Chan Yong
    Thamsen, Bente
    Bluemel, Bastian
    Lommel, Michael
    Karakaya, Tamer
    Paschereit, Christian Oliver
    Affeld, Klaus
    Kertzscher, Ulrich
    ARTIFICIAL ORGANS, 2016, 40 (11) : E192 - E202
  • [37] Development of Pressure Estimation for External Rotary Blood Pump
    Diloksumpan, Paweena
    Naiyanetr, Phornphop
    6TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2013), 2013,
  • [38] Heart Failure and Rotary Blood Pump Summit 2004
    Golding, LAR
    ARTIFICIAL ORGANS, 2005, 29 (07) : 517 - 517
  • [39] Implantation of the VentrAssist implantable rotary blood pump in sheep
    James, NL
    Van Der Meer, AL
    Edwards, GA
    Snelling, SR
    Begg, JD
    Esmore, DS
    Woodard, JC
    ASAIO JOURNAL, 2003, 49 (04) : 454 - 458
  • [40] Fluid dynamic characteristics of the VentrAssist rotary blood pump
    Tansley, G
    Vidakovic, S
    Reizes, J
    ARTIFICIAL ORGANS, 2000, 24 (06) : 483 - 487