In vitro analysis of the flow fields of a rotary blood pump

被引:0
|
作者
Morsi, Y [1 ]
Yang, W [1 ]
Chan, S [1 ]
机构
[1] Swinburne Univ Technol, Sch Sci & Engn, Hawthorn, Vic 3122, Australia
关键词
rotary blood pump; laser Doppler anemometry; computational fluid dynamics;
D O I
暂无
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Thrombosis formation and hemolysis have been linked to the dynamics of the flowing blood and the hydrodynamic performance of the pump in a rotary blood pumps and ventricular assist devices (VADs). Hemolysis occurs as the blood passes through the pump housing and thrombosis in stagnation and low velocity regions. In our on-going research on VAD some experiments using LDA and CFD numerical analysis were performed on the Medtronic and Terumo blood pumps respectively. In this paper preliminary flow characteristics in terms of mean velocity and tangential velocity vectors are presented and discussed. These preliminary in vitro test data reveal that the use of LDA and CFD techniques are powerful tools in new pump designs and pump improvement.
引用
收藏
页码:875 / 880
页数:6
相关论文
共 50 条
  • [1] Numerical analysis of the flow characteristics of rotary blood pump
    Morsi Y.S.
    Yang W.
    Witt P.J.
    Ahmed A.M.
    Umezu M.
    Journal of Artificial Organs, 2001, 4 (1) : 54 - 60
  • [2] Estimation of the native cardiac output from a rotary blood pump flow: In vitro study
    Nakata, K
    Ohashi, Y
    Tayama, E
    Ohtsuka, G
    Takami, Y
    Mueller, J
    Glueck, J
    Nose, Y
    ARTIFICIAL ORGANS, 1998, 22 (05) : 411 - 413
  • [3] COMPUTATIONAL FLOW OPTIMIZATION OF ROTARY BLOOD PUMP COMPONENTS
    ANTAKI, JF
    GHATTAS, O
    BURGREEN, GW
    HE, BC
    ARTIFICIAL ORGANS, 1995, 19 (07) : 608 - 615
  • [4] Gain Scheduling Flow Control of a Rotary Blood Pump
    Bergmann, Lukas
    Rueschen, Daniel
    Amacher, Raffael
    Nelles, Oliver
    Leonhardt, Steffen
    Walter, Marian
    FORSCHUNG IM INGENIEURWESEN-ENGINEERING RESEARCH, 2018, 82 (01): : 21 - 31
  • [5] Flow Field Analysis of a Centrifugal Rotary Blood Pump under Active Speed Modulations
    Huang F.
    Wang C.
    Ruan X.
    1600, Chinese Mechanical Engineering Society (32): : 2915 - 2923
  • [6] Noninvasive pulsatile flow estimation for an implantable rotary blood pump
    Karantonis, Dean M.
    Cloherty, Shaun L.
    Mason, David G.
    Ayre, Peter J.
    Lovell, Nigel H.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 1018 - +
  • [7] Mathematical modeling of a rotary blood pump in a pulsatile flow environment
    Pirbodaghi, T.
    Vandenberghe, S.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2010, 15 : 20 - 20
  • [8] PIV investigations of the flow field in the volute of a rotary blood pump
    Sankovic, JM
    Kadambi, JR
    Mehta, M
    Smith, WA
    Wernet, MP
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (05): : 730 - 734
  • [9] Design and evaluation of a pulsatile flow rotary vane blood pump
    Li, Mengtang
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2023, 237 (11) : 2561 - 2574
  • [10] Sensorless flow and head estimation in the VentrAssist rotary blood pump
    Ayre, PJ
    Vidakovic, SS
    Tansley, GD
    Watterson, PA
    Lovell, NH