In vitro analysis of the flow fields of a rotary blood pump

被引:0
|
作者
Morsi, Y [1 ]
Yang, W [1 ]
Chan, S [1 ]
机构
[1] Swinburne Univ Technol, Sch Sci & Engn, Hawthorn, Vic 3122, Australia
关键词
rotary blood pump; laser Doppler anemometry; computational fluid dynamics;
D O I
暂无
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Thrombosis formation and hemolysis have been linked to the dynamics of the flowing blood and the hydrodynamic performance of the pump in a rotary blood pumps and ventricular assist devices (VADs). Hemolysis occurs as the blood passes through the pump housing and thrombosis in stagnation and low velocity regions. In our on-going research on VAD some experiments using LDA and CFD numerical analysis were performed on the Medtronic and Terumo blood pumps respectively. In this paper preliminary flow characteristics in terms of mean velocity and tangential velocity vectors are presented and discussed. These preliminary in vitro test data reveal that the use of LDA and CFD techniques are powerful tools in new pump designs and pump improvement.
引用
收藏
页码:875 / 880
页数:6
相关论文
共 50 条
  • [21] Numerical calculation and analysis of cavitation flow in rotary lobe pump
    Jiang, Xiaoqin
    Li, Yibin
    Guo, Dongsheng
    Du, Jun
    IPPTA: Quarterly Journal of Indian Pulp and Paper Technical Association, 2018, 30 (02) : 166 - 175
  • [22] In vitro performance of a centrifugal, a mixed flow, and an axial flow blood pump
    Medical Informatics, Miyazaki Medical College Hospital, Miyazaki, Japan
    不详
    不详
    不详
    Artif. Organs, 5 (366-370):
  • [23] In vitro performance of a centrifugal, a mixed flow, and an axial flow blood pump
    Araki, K
    Anai, H
    Oshikawa, M
    Nakamura, K
    Onitsuka, T
    ARTIFICIAL ORGANS, 1998, 22 (05) : 366 - 370
  • [24] Monitoring of Heart Rate Variability in Rotary Blood Pump Recipients Is Possible Using the Pump Flow Only
    Moscato, F.
    Granegger, M.
    Edelmayer, M.
    Zimpfer, D.
    Wieselthaler, G.
    Schima, H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S265 - S265
  • [25] Characterization of a pediatric rotary blood pump
    de Melo T.R.
    Vasconcelos F.J.S.
    Ribeiro L.H.R.D.
    Bacht S.
    Cestari I.A.
    Neto J.S.D.R.
    Lima A.M.N.
    Research on Biomedical Engineering, 2018, 34 (04) : 299 - 309
  • [26] Control system for an rotary blood pump
    Nakata, K.
    Shiono, M.
    Orime, Y.
    Yagi, S.
    Yamamoto, T.
    Okumura, H.
    Kashiwazaki, A.
    Choh, S.
    Hirose, H.
    Saito, A.
    Taniguchi, T.
    Negishi, N.
    Sezai, Y.
    Sankai, Y.
    Fujisawa, A.
    Makinouchi, K.
    Yokokawa, M.
    ASAIO Journal, 2000, 46 (02)
  • [27] A novel rotary blood pump for HFpEF
    Gude, E.
    Fiane, D. R.
    EUROPEAN JOURNAL OF HEART FAILURE, 2019, 21 : 348 - 348
  • [28] A Novel Rotary Blood Pump for HFpEF
    Gude, E.
    Fiane, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : S342 - S342
  • [29] CFD MODELLING OF ROTARY BLOOD PUMP
    Szwast, M.
    Moskal, A.
    Piatkiewicz, W.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 702 - 702
  • [30] The Effect of Compliant Inflow Cannulae on the Hemocompatibility of Rotary Blood Pump Circuits in an In Vitro Model
    Pauls, Jo P.
    Nandakumar, Deepika
    Horobin, Jarod
    Prendeville, Justin D.
    Simmonds, Michael J.
    Fraser, John F.
    Tansley, Geoff
    Gregory, Shaun D.
    ARTIFICIAL ORGANS, 2017, 41 (10) : E118 - E128