Influence of measurement parameters on frequency response analysis diagnosis of oil-immersed transformer

被引:0
|
作者
机构
[1] [1,Sano, Takahiro
[2] 1,Miyagi, Katsunori
来源
| 1600年 / John Wiley and Sons Inc卷 / 186期
关键词
Appropriate monitoring and maintenance become important as an oil-immersed transformer ages. Generally; dissolved gas analysis (DGA) is effective for the online diagnosis; and if an abnormality is detected; frequency response analysis (FRA) is effective for the offline diagnosis to localize the failed part. FRA diagnosis detects a slight change of waveforms; however; external factors may influence the results. Here; we discuss the influence of an insulating oil presence; tap position; and measurement lead wire length as possible parameters that influence the FRA characteristics. We confirmed that the measurement parameters examined here greatly influenced the FRA characteristics. In the actual diagnosis; it is important to remove these external parameters as much as possible; and keep a detailed record of the measurement parameters. © 2013 Wiley Periodicals; Inc;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
相关论文
共 50 条
  • [1] Influence of Measurement Parameters on Frequency Response Analysis Diagnosis of Oil-Immersed Transformer
    Sano, Takahiro
    Miyagi, Katsunori
    ELECTRICAL ENGINEERING IN JAPAN, 2014, 186 (01) : 18 - 25
  • [2] Application of Dielectric Response for Oil-immersed Transformer
    Yang, Shuangsuo
    Dong, Ming
    Zhang, Guanjun
    Zhang, Zhi
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 370 - +
  • [3] Fault Diagnosis Model of Oil-immersed Transformer Based on Return Voltage Measurement
    Chen, Ming
    Hu, Shuilian
    Mo, Zhenhua
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 72 - 76
  • [4] Fault Diagnosis Model of Oil-immersed Transformer Based on Return Voltage Measurement
    Chen Ming
    Hu Shui-lian
    Mo Zhen-hua
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 313 - 317
  • [5] Application of frequency domain spectroscopy to the insulation diagnosis of oil-immersed power transformer on site
    Zhang, Zhi
    Dong, Ming
    Yang, Shuang-Suo
    Jiang, Wei
    Zhang, Guan-Jun
    Yan, Zhang
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (07): : 1648 - 1653
  • [6] Data augmentation for fault diagnosis of oil-immersed power transformer
    Li, Ke
    Li, Jian
    Huang, Qi
    Chen, Yuhui
    ENERGY REPORTS, 2023, 9 : 1211 - 1219
  • [7] Data augmentation for fault diagnosis of oil-immersed power transformer
    Li, Ke
    Li, Jian
    Huang, Qi
    Chen, Yuhui
    ENERGY REPORTS, 2023, 9 : 1211 - 1219
  • [8] A New Testing Method for the Dielectric Response of Oil-Immersed Transformer
    Wang, Dongyang
    Zhou, Lijun
    Yang, Zhi-Xin
    Cui, Yi
    Wang, Lujia
    Jiang, Junfei
    Guo, Lei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (12) : 10833 - 10843
  • [9] Insulation Diagnosis for 220kV Oil-Immersed Current Transformer by Frequency Dielectric Spectroscopy
    Peng, Hua-dong
    Dong, Ming
    Ren, Ming
    Miao, Jin
    Zhang, Zhi
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 69 - 73
  • [10] Moisture Diagnosis of Transformer Oil-Immersed Insulation With Intelligent Technique and Frequency-Domain Spectroscopy
    Liu, Jiefeng
    Fan, Xianhao
    Zhang, Chaohai
    Lai, Chun Sing
    Zhang, Yiyi
    Zheng, Hanbo
    Lai, Loi Lei
    Zhang, Enze
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2021, 17 (07) : 4624 - 4634