Influence of measurement parameters on frequency response analysis diagnosis of oil-immersed transformer

被引:0
|
作者
机构
[1] [1,Sano, Takahiro
[2] 1,Miyagi, Katsunori
来源
| 1600年 / John Wiley and Sons Inc卷 / 186期
关键词
Appropriate monitoring and maintenance become important as an oil-immersed transformer ages. Generally; dissolved gas analysis (DGA) is effective for the online diagnosis; and if an abnormality is detected; frequency response analysis (FRA) is effective for the offline diagnosis to localize the failed part. FRA diagnosis detects a slight change of waveforms; however; external factors may influence the results. Here; we discuss the influence of an insulating oil presence; tap position; and measurement lead wire length as possible parameters that influence the FRA characteristics. We confirmed that the measurement parameters examined here greatly influenced the FRA characteristics. In the actual diagnosis; it is important to remove these external parameters as much as possible; and keep a detailed record of the measurement parameters. © 2013 Wiley Periodicals; Inc;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
相关论文
共 50 条
  • [31] Improvement for the upper part of oil-immersed transformer tank
    Huang, Xiyou
    Guo, Yuping
    Bianyaqi/Transformer, 1999, 36 (11): : 9 - 12
  • [32] Increase of static electrification in an aged oil-immersed transformer
    Kobayashi, Takayuki
    Yajima, Kouji
    Yamada, Shin
    Amimoto, Tsuyoshi
    Hosokawa, Noboru
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 2009, 167 (03): : 10 - 19
  • [33] Study on the deformation of the oil-immersed transformer tank by FEA
    Zhang, Jianhua
    Sun, Lingyu
    Zhang, Xiaojun
    Li, Jiapeng
    EQUIPMENT MANUFACTURING TECHNOLOGY, 2012, 422 : 51 - +
  • [34] Increase of Static Electrification in an Aged Oil-Immersed Transformer
    Kobayashi, Takayuki
    Yajima, Kouji
    Yamada, Shin
    Amimoto, Tsuyoshi
    Hosokawa, Noboru
    ELECTRICAL ENGINEERING IN JAPAN, 2009, 167 (03) : 10 - 19
  • [35] Increase of static electrification in an aged oil-immersed transformer
    Tokyo Electric Power Company, 1-1-3, Uchisaiwai-chou, Chiyoda-ku, Tokyo 100-8560
    不详
    不详
    不详
    不详
    不详
    IEEJ Trans. Power Energy, 2007, 9 (1025-1032+7):
  • [36] OIL-IMMERSED POWER TRANSFORMER OVERLOAD CALCULATIONS BY COMPUTER
    BLAKE, JH
    KELLY, EJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1969, PA88 (08): : 1205 - &
  • [37] An intelligent monitoring and diagnosis system for 330kV oil-immersed power transformer
    State Key Laboratory of Electrical Insulation for Power Equipment, Xi'An Jiaotong University, China
    Proc Int Symp Electr Insul Mater, (257-260):
  • [38] Thermal circuit model parameters identification of oil-immersed transformer based on PSO algorithm
    Zhang, Linli
    Li, Lisheng
    Jiang, Bin
    Li, Rong
    Li, Hongmei
    Dong, Xiao
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON MECHATRONICS, MATERIALS, CHEMISTRY AND COMPUTER ENGINEERING 2015 (ICMMCCE 2015), 2015, 39 : 927 - 932
  • [39] Fault diagnosis method for oil-immersed transformer based on XGBoost optimized by genetic algorithm
    Zhang Y.
    Feng B.
    Chen Y.
    Liao W.
    Guo C.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2021, 41 (02): : 200 - 206
  • [40] A Hybrid machine-learning method for oil-immersed power transformer fault diagnosis
    Yang, Xiaohui
    Chen, Wenkai
    Li, Anyi
    Yang, Chunsheng
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 15 (04) : 501 - 507