Influence of measurement parameters on frequency response analysis diagnosis of oil-immersed transformer

被引:0
|
作者
机构
[1] [1,Sano, Takahiro
[2] 1,Miyagi, Katsunori
来源
| 1600年 / John Wiley and Sons Inc卷 / 186期
关键词
Appropriate monitoring and maintenance become important as an oil-immersed transformer ages. Generally; dissolved gas analysis (DGA) is effective for the online diagnosis; and if an abnormality is detected; frequency response analysis (FRA) is effective for the offline diagnosis to localize the failed part. FRA diagnosis detects a slight change of waveforms; however; external factors may influence the results. Here; we discuss the influence of an insulating oil presence; tap position; and measurement lead wire length as possible parameters that influence the FRA characteristics. We confirmed that the measurement parameters examined here greatly influenced the FRA characteristics. In the actual diagnosis; it is important to remove these external parameters as much as possible; and keep a detailed record of the measurement parameters. © 2013 Wiley Periodicals; Inc;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
相关论文
共 50 条
  • [41] Fault Diagnosis of Oil-Immersed Transformer based on TSNE and IBA-SA-SVM
    Feng, Wenqing
    Zhang, Guoyong
    Ouyang, Yi
    Pi, Xinyu
    He, Lifu
    Luo, Jing
    Yi, Lingzhi
    Guo, You
    Recent Patents on Mechanical Engineering, 2022, 15 (05) : 504 - 514
  • [42] An Intelligent Monitoring and Diagnosis System For 330kV Oil-immersed Power Transformer
    Zhou, Hai-Bin
    Dong, Ming
    Yang, Dai-Yong
    PROCEEDINGS OF 2011 INTERNATIONAL CONFERENCE ON ELECTRICAL INSULATING MATERIALS (ISEIM), 2011, : 257 - 260
  • [43] The Study and Analysis of Oil-immersed Power Transformer by Using Artificial Neural Network for Designing Program Apply in the Industry of Testing Oil-immersed Transformers
    Boonsaner, Nutthaphan
    Chancharoensook, Phop
    Bunnag, Chisanucha
    Suwantaweesuk, Achirawit
    Vongphanich, Kiattisak
    2020 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD 2020), 2020, : 274 - 277
  • [44] Dissolved gases forecast to enhance oil-immersed transformer fault diagnosis with grey prediction-clustering analysis
    Lin, Chia-Hung
    Chen, Jian-Liung
    Huang, Ping-Zan
    EXPERT SYSTEMS, 2011, 28 (02) : 123 - 137
  • [45] An analysis of temperature of oil-immersed transformer under non-linear load
    Thammarat, C
    Suechoey, B
    Tadsuan, S
    Kinnares, V
    Bunjongjit, S
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 517 - 521
  • [46] RAPID MEASUREMENT OF DETERIORATION OF OIL-IMMERSED PAPER
    HINO, T
    SUGANUMA, T
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1972, EI 7 (03): : 122 - &
  • [47] Polarization loss analysis and ageing characterisation of transformer oil-immersed insulation by using decoupled frequency domain spectroscopy
    Fan, Xianhao
    Liu, Jiefeng
    Zhang, Yiyi
    Ding, Zheshi
    Wang, Qingyin
    HIGH VOLTAGE, 2022, 7 (03) : 575 - 585
  • [48] Applying Response Surface Method to Oil-Immersed Transformer Cooling System for Design Optimization
    Zhang, Yunpeng
    Ho, S. L.
    Fu, Weinong
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (11)
  • [49] Study on temperature distribution in oil-immersed inverted current transformer
    Yang, Xiaoping
    Wu, Yiming
    Li, Jiansheng
    Wei, Chao
    Wang, Shengquan
    Huang, Leifeng
    Li, Bonan
    Wang, Youyuan
    2019 IEEE 20TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2019,
  • [50] Heat transfer comparison of nanofluid filled transformer and traditional oil-immersed transformer
    Zhang, Yunpeng
    Ho, Siu-lau
    Fu, Weinong
    AIP ADVANCES, 2018, 8 (05)