Influence of Measurement Parameters on Frequency Response Analysis Diagnosis of Oil-Immersed Transformer

被引:3
|
作者
Sano, Takahiro
Miyagi, Katsunori
机构
关键词
oil-immersed transformers; frequency response analysis (FRA); fault diagnosis;
D O I
10.1002/eej.22313
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Appropriate monitoring and maintenance become important as an oil-immersed transformer ages. Generally, dissolved gas analysis (DGA) is effective for the online diagnosis, and if an abnormality is detected, frequency response analysis (FRA) is effective for the offline diagnosis to localize the failed part. FRA diagnosis detects a slight change of waveforms; however, external factors may influence the results. Here, we discuss the influence of an insulating oil presence, tap position, and measurement lead wire length as possible parameters that influence the FRA characteristics. We confirmed that the measurement parameters examined here greatly influenced the FRA characteristics. In the actual diagnosis, it is important to remove these external parameters as much as possible, and keep a detailed record of the measurement parameters. (c) 2013 Wiley Periodicals, Inc. Electr Eng Jpn, 186(1): 18-25, 2013; Published online in Wiley Online Library (wileyonlinelibrary.com). DOI 10.1002/eej.22313
引用
收藏
页码:18 / 25
页数:8
相关论文
共 50 条
  • [2] Application of Dielectric Response for Oil-immersed Transformer
    Yang, Shuangsuo
    Dong, Ming
    Zhang, Guanjun
    Zhang, Zhi
    [J]. ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 370 - +
  • [3] Fault Diagnosis Model of Oil-immersed Transformer Based on Return Voltage Measurement
    Chen, Ming
    Hu, Shuilian
    Mo, Zhenhua
    [J]. 2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 72 - 76
  • [4] Fault Diagnosis Model of Oil-immersed Transformer Based on Return Voltage Measurement
    Chen Ming
    Hu Shui-lian
    Mo Zhen-hua
    [J]. 2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 313 - 317
  • [5] Application of frequency domain spectroscopy to the insulation diagnosis of oil-immersed power transformer on site
    Zhang, Zhi
    Dong, Ming
    Yang, Shuang-Suo
    Jiang, Wei
    Zhang, Guan-Jun
    Yan, Zhang
    [J]. Gaodianya Jishu/High Voltage Engineering, 2009, 35 (07): : 1648 - 1653
  • [6] Data augmentation for fault diagnosis of oil-immersed power transformer
    Li, Ke
    Li, Jian
    Huang, Qi
    Chen, Yuhui
    [J]. ENERGY REPORTS, 2023, 9 : 1211 - 1219
  • [7] Data augmentation for fault diagnosis of oil-immersed power transformer
    Li, Ke
    Li, Jian
    Huang, Qi
    Chen, Yuhui
    [J]. ENERGY REPORTS, 2023, 9 : 1211 - 1219
  • [8] A New Testing Method for the Dielectric Response of Oil-Immersed Transformer
    Wang, Dongyang
    Zhou, Lijun
    Yang, Zhi-Xin
    Cui, Yi
    Wang, Lujia
    Jiang, Junfei
    Guo, Lei
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (12) : 10833 - 10843
  • [9] Insulation Diagnosis for 220kV Oil-Immersed Current Transformer by Frequency Dielectric Spectroscopy
    Peng, Hua-dong
    Dong, Ming
    Ren, Ming
    Miao, Jin
    Zhang, Zhi
    [J]. 2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 69 - 73
  • [10] Moisture Diagnosis of Transformer Oil-Immersed Insulation With Intelligent Technique and Frequency-Domain Spectroscopy
    Liu, Jiefeng
    Fan, Xianhao
    Zhang, Chaohai
    Lai, Chun Sing
    Zhang, Yiyi
    Zheng, Hanbo
    Lai, Loi Lei
    Zhang, Enze
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2021, 17 (07) : 4624 - 4634