Comparative analysis of three jaw motion tracking systems: A study on precision and trueness

被引:1
|
作者
Zhao, Wei [1 ]
Feng, Yue [1 ]
Cao, Rongkai [1 ]
Sun, Jiyu [1 ]
Zhang, Jiayao [1 ]
Zhao, Xinhuan [1 ]
Liu, Weicai [1 ,2 ,3 ,4 ]
机构
[1] Tongji Univ, Shanghai Engn Res Ctr Tooth Restorat & Regenerat, Stomatol Hosp, Shanghai, Peoples R China
[2] Tongji Univ, Stomatol Hosp, Tongji Res Inst Stomatol, Shanghai, Peoples R China
[3] Tongji Univ, Stomatol Hosp, Dept Prosthodont, Shanghai, Peoples R China
[4] Tongji Univ, Dent Sch, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
KaVo ARCUSdigma system; Modjaw system; precision; SDiMatriX system; trueness; SAGITTAL CONDYLAR INCLINATION; GENERATED OCCLUSAL TRACINGS; VIRTUAL ARTICULATOR; SIDE SHIFT; SETTINGS; CHILDREN;
D O I
10.1111/jopr.13953
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:The purpose of this study was to assess the precision and trueness of threejaw motion tracking systems, the KaVo ARCUSdigma system, SDiMatriX system, andModjaw system, in recording mandibular movements based on optical and ultrasonicprinciples.Materials and Methods:Twenty-five healthy subjects were selected for the presentstudy to measure protrosive movement and left and right lateral movements using thethree jaw motion tracking systems. Each subject's mandibular movement was recordedtwice with a 1-week interval. Five parameters-sagittal condylar inclination (SCI)angle, incisal guide angle, Bennett angle, lateral condylar inclination angle, and Fis-cher's angle-were acquired for further analysis. The precision of the jaw motiontracking systems was evaluated by comparing the results of two measurements of thesame parameter. Simultaneously, cone beam computed tomography (CBCT) was uti-lized during the initial data acquisition and was aligned with intercuspal position (ICP)and edge-to-edge occlusion intraoral scan data. Bone landmarks were used to calculatebilateral SCI as a reference for comparison with the SCI values from each jaw motiontracking system. An independent-samplet-test was conducted to compare parameterdifferences, with statistical significance set at ap-value below 0.05.Results:There were no significant differences among the three jaw motion trackingsystems regarding the corrected values of SCI, incisal guide angle, Bennett angle,lateral condylar inclination angle, and Fischer's angle during the 1-week interval(p>0.05). The values of bilateral SCI obtained by CBCT were 48.57 +/- 6.74 (L) and48.35 +/- 5.28 (R), respectively. No significant differences were found between the ref-erence SCI and those parameters measured by the KaVo ARCUSdigma system andthe Modjaw system (p>0.05), while the results obtained from the SDiMatriX systemindicated a significant difference compared to the reference SCI (p<0.05).Conclusions:The three jaw motion tracking systems exhibited favorable results interms of precision. Regarding trueness, both the KaVo ARCUSdigma system and theModjaw system demonstrated a satisfactory levels suitable for applications in digi-tal prosthodontics within clinical settings. However, further refinement is needed toenhance the trueness of the SDiMatriX system.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 50 条
  • [1] Trueness and Precision of Two Intraoral Scanners: A Comparative In Vitro Study
    Rotar, Raul Nicolae
    Jivanescu, Anca
    Ille, Codruta
    Podariu, Angela Codruta
    Jumanca, Daniela Elisabeta
    Matichescu, Ana-Maria
    Balean, Octavia
    Rusu, Laura Cristina
    SCANNING, 2019, 2019
  • [2] Smartphone and computer cephalometric analysis: A trueness and precision study
    Amorim, Monica
    Diamantino, Fernanda
    Pereira, Rui
    Jardim, Luis
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2022, 63 (04): : 204 - 212
  • [3] Quantitative Analysis on Tracking Errors in Ultra-precision Motion Systems
    Dai L.
    Li X.
    Zhu Y.
    Zhang M.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (16): : 4910 - 4918
  • [4] Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study
    Mangano, Francesco G.
    Veronesi, Giovanni
    Hauschild, Uli
    Mijiritsky, Eitan
    Mangano, Carlo
    PLOS ONE, 2016, 11 (09):
  • [5] Toward improving tracking precision in motion capture systems
    Retinger, Marek
    Michalski, Jacek
    Kozierski, Piotr
    Giernacki, Wojciech
    2023 INTERNATIONAL CONFERENCE ON UNMANNED AIRCRAFT SYSTEMS, ICUAS, 2023, : 919 - 925
  • [6] Human motion tracking: A comparative study
    Mrabti, Wafae
    Baibai, Kaoutar
    Bellach, Benaissa
    Thami, Rachid Oulad Haj
    Tairi, Hamid
    SECOND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING IN DATA SCIENCES (ICDS2018), 2019, 148 : 145 - 153
  • [7] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Francesco Guido Mangano
    Uli Hauschild
    Giovanni Veronesi
    Mario Imburgia
    Carlo Mangano
    Oleg Admakin
    BMC Oral Health, 19
  • [8] Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study
    Mangano, Francesco Guido
    Hauschild, Uli
    Veronesi, Giovanni
    Imburgia, Mario
    Mangano, Carlo
    Admakin, Oleg
    BMC ORAL HEALTH, 2019, 19 (1)
  • [9] Trueness and Precision of Eight Intraoral Scanners with Different Finishing Line Designs: A Comparative In Vitro Study
    Falih, Mina Yahia
    Majeed, Manhal A.
    EUROPEAN JOURNAL OF DENTISTRY, 2023, 17 (04) : 1056 - 1064
  • [10] Comparative analysis of jaw morphology and temporomandibular disorders: A three-dimension imaging study
    Colonna, Anna
    Manfredini, Daniele
    Lombardo, Luca
    Muscatello, Luca
    Marchese-Ragona, Rosario
    Arveda, Niki
    Siciliani, Giuseppe
    CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 2020, 38 (03): : 158 - 167