Comparative analysis of three jaw motion tracking systems: A study on precision and trueness

被引:1
|
作者
Zhao, Wei [1 ]
Feng, Yue [1 ]
Cao, Rongkai [1 ]
Sun, Jiyu [1 ]
Zhang, Jiayao [1 ]
Zhao, Xinhuan [1 ]
Liu, Weicai [1 ,2 ,3 ,4 ]
机构
[1] Tongji Univ, Shanghai Engn Res Ctr Tooth Restorat & Regenerat, Stomatol Hosp, Shanghai, Peoples R China
[2] Tongji Univ, Stomatol Hosp, Tongji Res Inst Stomatol, Shanghai, Peoples R China
[3] Tongji Univ, Stomatol Hosp, Dept Prosthodont, Shanghai, Peoples R China
[4] Tongji Univ, Dent Sch, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
KaVo ARCUSdigma system; Modjaw system; precision; SDiMatriX system; trueness; SAGITTAL CONDYLAR INCLINATION; GENERATED OCCLUSAL TRACINGS; VIRTUAL ARTICULATOR; SIDE SHIFT; SETTINGS; CHILDREN;
D O I
10.1111/jopr.13953
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:The purpose of this study was to assess the precision and trueness of threejaw motion tracking systems, the KaVo ARCUSdigma system, SDiMatriX system, andModjaw system, in recording mandibular movements based on optical and ultrasonicprinciples.Materials and Methods:Twenty-five healthy subjects were selected for the presentstudy to measure protrosive movement and left and right lateral movements using thethree jaw motion tracking systems. Each subject's mandibular movement was recordedtwice with a 1-week interval. Five parameters-sagittal condylar inclination (SCI)angle, incisal guide angle, Bennett angle, lateral condylar inclination angle, and Fis-cher's angle-were acquired for further analysis. The precision of the jaw motiontracking systems was evaluated by comparing the results of two measurements of thesame parameter. Simultaneously, cone beam computed tomography (CBCT) was uti-lized during the initial data acquisition and was aligned with intercuspal position (ICP)and edge-to-edge occlusion intraoral scan data. Bone landmarks were used to calculatebilateral SCI as a reference for comparison with the SCI values from each jaw motiontracking system. An independent-samplet-test was conducted to compare parameterdifferences, with statistical significance set at ap-value below 0.05.Results:There were no significant differences among the three jaw motion trackingsystems regarding the corrected values of SCI, incisal guide angle, Bennett angle,lateral condylar inclination angle, and Fischer's angle during the 1-week interval(p>0.05). The values of bilateral SCI obtained by CBCT were 48.57 +/- 6.74 (L) and48.35 +/- 5.28 (R), respectively. No significant differences were found between the ref-erence SCI and those parameters measured by the KaVo ARCUSdigma system andthe Modjaw system (p>0.05), while the results obtained from the SDiMatriX systemindicated a significant difference compared to the reference SCI (p<0.05).Conclusions:The three jaw motion tracking systems exhibited favorable results interms of precision. Regarding trueness, both the KaVo ARCUSdigma system and theModjaw system demonstrated a satisfactory levels suitable for applications in digi-tal prosthodontics within clinical settings. However, further refinement is needed toenhance the trueness of the SDiMatriX system.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 50 条
  • [41] A Comparative Analysis of Three Unit Redundant Systems with Three Types of Failures
    Ibrahim Yusuf
    Nafiu Hussaini
    Arabian Journal for Science and Engineering, 2014, 39 : 3337 - 3349
  • [42] A Comparative Analysis of Three Unit Redundant Systems with Three Types of Failures
    Yusuf, Ibrahim
    Hussaini, Nafiu
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (04) : 3337 - 3349
  • [43] Precision Analysis of Simulation Systems with Hardware-in-loop Caused by Performance of Three-Axis Virtual Flight Motion Simulator
    Wang, Tao
    Zhu, Ming-chao
    Yin, Sheng-li
    Jia, Hong-guang
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 4860 - +
  • [44] ANALYSIS THE CHARACTERISTIC OF ORAL BEHAVIORS BY THE THREE DIMENSIONAL JAW-TRACKING SYSTEM IN FREELY MOVING RATS
    Rahman, Mostafeezur
    Kurose, Masayuki
    Yamamura, Kensuke
    Hossain, Zakir
    Saito, Kimiko
    Iwata, Koichi
    Yamada, Yoshiaki
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2009, 59 : 479 - 479
  • [45] High-precision, three-dimensional tracking of mouse whisker movements with optical motion capture technology
    Roy, Snigdha
    Bryant, Jeri L.
    Cao, Ying
    Heck, Detlef H.
    FRONTIERS IN BEHAVIORAL NEUROSCIENCE, 2011, 5
  • [46] Analysis of the Importance of the Motion Used in the Resistance of Different Mechanical Instrumentation Systems in Endodontics: A Comparative Study
    Mena-Alvarez, Jesus
    Almanzor-Lopez, Manuel
    Quispe-Lopez, Norberto
    De Pedro-Munoz, Ana
    Rico-Romano, Cristina
    MATERIALS, 2022, 15 (13)
  • [47] BASE MOTION SENSITIVITY ANALYSIS FOR AIRBORNE ILIC POINTING AND TRACKING SYSTEMS
    NEGRO, JE
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1977, 13 (04) : 449 - 449
  • [48] DYNAMICAL SYSTEMS APPROACH TO MOTION ANALYSIS AND TO TRACKING THE ASSOCIATED PHYSIOLOGIC PROCESSES
    Chelidze, David
    ANNALS OF BEHAVIORAL MEDICINE, 2012, 43 : S73 - S73
  • [49] COMPARATIVE METHODS FOR ANALYSIS OF PIPING SYSTEMS SUBJECTED TO SEISMIC MOTION
    HURE, D
    MORYSSE, M
    NUCLEAR ENGINEERING AND DESIGN, 1976, 38 (03) : 511 - 525
  • [50] Three-Dimensional Surgical Changes of Mandibular Proximal Segments Affect Outcome of Jaw Motion Analysis
    Ko, Ellen Wen-Ching
    Alazizi, Abdelmounem Issam
    Lin, Cheng-Hui
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (05) : 971 - 984