Comparative analysis of three jaw motion tracking systems: A study on precision and trueness

被引:1
|
作者
Zhao, Wei [1 ]
Feng, Yue [1 ]
Cao, Rongkai [1 ]
Sun, Jiyu [1 ]
Zhang, Jiayao [1 ]
Zhao, Xinhuan [1 ]
Liu, Weicai [1 ,2 ,3 ,4 ]
机构
[1] Tongji Univ, Shanghai Engn Res Ctr Tooth Restorat & Regenerat, Stomatol Hosp, Shanghai, Peoples R China
[2] Tongji Univ, Stomatol Hosp, Tongji Res Inst Stomatol, Shanghai, Peoples R China
[3] Tongji Univ, Stomatol Hosp, Dept Prosthodont, Shanghai, Peoples R China
[4] Tongji Univ, Dent Sch, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
KaVo ARCUSdigma system; Modjaw system; precision; SDiMatriX system; trueness; SAGITTAL CONDYLAR INCLINATION; GENERATED OCCLUSAL TRACINGS; VIRTUAL ARTICULATOR; SIDE SHIFT; SETTINGS; CHILDREN;
D O I
10.1111/jopr.13953
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:The purpose of this study was to assess the precision and trueness of threejaw motion tracking systems, the KaVo ARCUSdigma system, SDiMatriX system, andModjaw system, in recording mandibular movements based on optical and ultrasonicprinciples.Materials and Methods:Twenty-five healthy subjects were selected for the presentstudy to measure protrosive movement and left and right lateral movements using thethree jaw motion tracking systems. Each subject's mandibular movement was recordedtwice with a 1-week interval. Five parameters-sagittal condylar inclination (SCI)angle, incisal guide angle, Bennett angle, lateral condylar inclination angle, and Fis-cher's angle-were acquired for further analysis. The precision of the jaw motiontracking systems was evaluated by comparing the results of two measurements of thesame parameter. Simultaneously, cone beam computed tomography (CBCT) was uti-lized during the initial data acquisition and was aligned with intercuspal position (ICP)and edge-to-edge occlusion intraoral scan data. Bone landmarks were used to calculatebilateral SCI as a reference for comparison with the SCI values from each jaw motiontracking system. An independent-samplet-test was conducted to compare parameterdifferences, with statistical significance set at ap-value below 0.05.Results:There were no significant differences among the three jaw motion trackingsystems regarding the corrected values of SCI, incisal guide angle, Bennett angle,lateral condylar inclination angle, and Fischer's angle during the 1-week interval(p>0.05). The values of bilateral SCI obtained by CBCT were 48.57 +/- 6.74 (L) and48.35 +/- 5.28 (R), respectively. No significant differences were found between the ref-erence SCI and those parameters measured by the KaVo ARCUSdigma system andthe Modjaw system (p>0.05), while the results obtained from the SDiMatriX systemindicated a significant difference compared to the reference SCI (p<0.05).Conclusions:The three jaw motion tracking systems exhibited favorable results interms of precision. Regarding trueness, both the KaVo ARCUSdigma system and theModjaw system demonstrated a satisfactory levels suitable for applications in digi-tal prosthodontics within clinical settings. However, further refinement is needed toenhance the trueness of the SDiMatriX system.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 50 条
  • [31] The relative merits of three different power transmission systems for precision tracking space mechanisms
    Meyer, J
    Petrou, A
    7TH EUROPEAN SPACE MECHANISMS & TRIBOLOGY SYMPOSIUM, PROCEEDINGS, 1997, 410 : 265 - 268
  • [32] Adaptive Robust Precision Motion Control of Systems With Unknown Input Dead-Zones: A Case Study With Comparative Experiments
    Hu, Chuxiong
    Yao, Bin
    Wang, Qingfeng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (06) : 2454 - 2464
  • [33] Precision NNLARC Motion Controller Design for Industrial Mechatronic Systems Under Complicated Disturbances: A Case Study With Comparative Experiments
    Wang, Ze
    Hu, Chuxiong
    Zhu, Yu
    Yao, Bin
    2016 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2016, : 252 - 257
  • [34] An Analysis of the Precision and Reliability of the Leap Motion Sensor and Its Suitability for Static and Dynamic Tracking
    Guna, Joze
    Jakus, Grega
    Pogacnik, Matevz
    Tomazic, Saso
    Sodnik, Jaka
    SENSORS, 2014, 14 (02): : 3702 - 3720
  • [35] Study on the role of fixation and tracking in visual motion analysis
    Hefei Univ of Technology, Hefei, China
    Zidonghua Xuebao/Acta Automatica Sinica, 1998, 24 (03): : 351 - 354
  • [36] Frequency response analysis for reset control systems: Application to predict precision of motion systems
    Zhang, Xinxin
    Kaczmarek, Marcin B.
    Hosseinnia, S. Hassan
    CONTROL ENGINEERING PRACTICE, 2024, 152
  • [37] A Comparative Study of the Fitness and Trueness of a Three-Unit Fixed Dental Prosthesis Fabricated Using Two Digital Workflows
    Jang, Daehee
    Son, Keunbada
    Lee, Kyu-bok
    APPLIED SCIENCES-BASEL, 2019, 9 (14):
  • [38] Utilizing additively manufactured custom devices to record mandibular motion by using optical jaw tracking systems: A dental technique
    Revilla-Leon, Marta
    Zeitler, Jonathan M.
    Gomez-Polo, Miguel
    Kois, John C.
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (04): : 560 - 566
  • [39] Performance-Oriented Precision LARC Tracking Motion Control of a Magnetically Levitated Planar Motor With Comparative Experiments
    Hu, Chuxiong
    Wang, Ze
    Zhu, Yu
    Zhang, Ming
    Liu, Hao
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (09) : 5763 - 5773
  • [40] Comparative Analysis Of Motion Based And Feature Based Algorithms For Object Detection And Tracking
    Vaidya, Bhaumik
    Paunwala, Chirag
    2017 INTERNATIONAL CONFERENCE ON SOFT COMPUTING AND ITS ENGINEERING APPLICATIONS (ICSOFTCOMP), 2017,