Comparative analysis of three jaw motion tracking systems: A study on precision and trueness

被引:1
|
作者
Zhao, Wei [1 ]
Feng, Yue [1 ]
Cao, Rongkai [1 ]
Sun, Jiyu [1 ]
Zhang, Jiayao [1 ]
Zhao, Xinhuan [1 ]
Liu, Weicai [1 ,2 ,3 ,4 ]
机构
[1] Tongji Univ, Shanghai Engn Res Ctr Tooth Restorat & Regenerat, Stomatol Hosp, Shanghai, Peoples R China
[2] Tongji Univ, Stomatol Hosp, Tongji Res Inst Stomatol, Shanghai, Peoples R China
[3] Tongji Univ, Stomatol Hosp, Dept Prosthodont, Shanghai, Peoples R China
[4] Tongji Univ, Dent Sch, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
KaVo ARCUSdigma system; Modjaw system; precision; SDiMatriX system; trueness; SAGITTAL CONDYLAR INCLINATION; GENERATED OCCLUSAL TRACINGS; VIRTUAL ARTICULATOR; SIDE SHIFT; SETTINGS; CHILDREN;
D O I
10.1111/jopr.13953
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose:The purpose of this study was to assess the precision and trueness of threejaw motion tracking systems, the KaVo ARCUSdigma system, SDiMatriX system, andModjaw system, in recording mandibular movements based on optical and ultrasonicprinciples.Materials and Methods:Twenty-five healthy subjects were selected for the presentstudy to measure protrosive movement and left and right lateral movements using thethree jaw motion tracking systems. Each subject's mandibular movement was recordedtwice with a 1-week interval. Five parameters-sagittal condylar inclination (SCI)angle, incisal guide angle, Bennett angle, lateral condylar inclination angle, and Fis-cher's angle-were acquired for further analysis. The precision of the jaw motiontracking systems was evaluated by comparing the results of two measurements of thesame parameter. Simultaneously, cone beam computed tomography (CBCT) was uti-lized during the initial data acquisition and was aligned with intercuspal position (ICP)and edge-to-edge occlusion intraoral scan data. Bone landmarks were used to calculatebilateral SCI as a reference for comparison with the SCI values from each jaw motiontracking system. An independent-samplet-test was conducted to compare parameterdifferences, with statistical significance set at ap-value below 0.05.Results:There were no significant differences among the three jaw motion trackingsystems regarding the corrected values of SCI, incisal guide angle, Bennett angle,lateral condylar inclination angle, and Fischer's angle during the 1-week interval(p>0.05). The values of bilateral SCI obtained by CBCT were 48.57 +/- 6.74 (L) and48.35 +/- 5.28 (R), respectively. No significant differences were found between the ref-erence SCI and those parameters measured by the KaVo ARCUSdigma system andthe Modjaw system (p>0.05), while the results obtained from the SDiMatriX systemindicated a significant difference compared to the reference SCI (p<0.05).Conclusions:The three jaw motion tracking systems exhibited favorable results interms of precision. Regarding trueness, both the KaVo ARCUSdigma system and theModjaw system demonstrated a satisfactory levels suitable for applications in digi-tal prosthodontics within clinical settings. However, further refinement is needed toenhance the trueness of the SDiMatriX system.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 50 条
  • [21] Comparative analysis of topic tracking systems' performance
    Abbey, K
    Carthy, J
    8TH WORLD MULTI-CONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL I, PROCEEDINGS: INFORMATION SYSTEMS, TECHNOLOGIES AND APPLICATIONS, 2004, : 189 - 193
  • [22] Comparative Study of the Trueness of the Inner Surface of Crowns Fabricated from Three Types of Lithium Disilicate Blocks
    Son, Keunbada
    Yu, Beom-young
    Yoon, Tae Ho
    Lee, Kyu-bok
    APPLIED SCIENCES-BASEL, 2019, 9 (09):
  • [23] Evaluation of the trueness and precision of eight extraoral laboratory scanners with a complete-arch model: a three-dimensional analysis
    Emir, Faruk
    Ayyildiz, Simel
    JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (04) : 434 - 439
  • [24] Mouth opening and jaw protrusion measured using three-dimensional motion analysis
    Roberts, M.
    Curtis, E.
    Mani, M.
    Goodwin, N.
    Wilkes, A. R.
    Zatman, T.
    Holt, C.
    ANAESTHESIA, 2010, 65 (04) : 428 - 429
  • [25] Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study
    Fattouh, Mohamed
    Kenawi, Laila Mohamed Mohamed
    Fattouh, Hesham
    IMAGING SCIENCE IN DENTISTRY, 2021, 51 (04) : 399 - 406
  • [26] Trueness and precision of 5 intraoral scanners for scanning edentulous and dentate complete-arch mandibular casts: A comparative in vitro study
    Braian, Michael
    Wennerberg, Ann
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (02): : 129 - 136
  • [27] Comparative analysis of the variability of fixed and tracking photovoltaic systems
    Heslop, Simon
    MacGill, Iain
    SOLAR ENERGY, 2014, 107 : 351 - 364
  • [28] Accuracy (trueness and precision) of four tablet-based applications for three-dimensional facial scanning: An in-vitro study
    Kuhlman, Deise Caldas
    Almuzian, Mohammed
    Coppini, Christianne
    Alzoubi, Emad Eddin
    JOURNAL OF DENTISTRY, 2023, 135
  • [29] Comparative Study of Three Methods of Maximum Power Point Tracking in Grid Connected Residential Photovoltaic Systems
    Javad Olamaei
    Sonia Abrishami
    Amir Hossein Merati Shirazi
    Iranian Journal of Science and Technology, Transactions of Electrical Engineering, 2022, 46 : 15 - 25
  • [30] Comparative Study of Three Methods of Maximum Power Point Tracking in Grid Connected Residential Photovoltaic Systems
    Olamaei, Javad
    Abrishami, Sonia
    Shirazi, Amir Hossein Merati
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF ELECTRICAL ENGINEERING, 2022, 46 (01) : 15 - 25