The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation An observational study

被引:4
|
作者
Zhang, Qing
Wu, Yi [1 ,2 ]
Huang, He [1 ]
Qin, Guanghao [1 ]
Li, Liangzhe [1 ]
Chen, Jiayan [1 ]
Che, Huixin [1 ]
Xu, Ling [1 ]
Moore, Jonathan E. [3 ]
He, Wei [1 ]
Yu, Sile [1 ]
Pazo, Emmanuel Eric [1 ]
He, Xingru [1 ]
机构
[1] He Eye Specialist Hosp, Shenyang, Peoples R China
[2] Dalian Med Univ, Affiliated Hosp 2, Dalian, Peoples R China
[3] Cathedral Eye Clin, Belfast, Antrim, North Ireland
关键词
implantable collamer lens; phakic intraocular lens; pupil size; quality of vision; HIGH MYOPIA; SIZE; MANAGEMENT; LASIK;
D O I
10.1097/MD.0000000000035198
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to assess the change in pupil size and its influence on subjective quality of vision (QoV) in subjects with implanted collamer lenses (ICLs). This retrospective study assessed 53 participants (53 eyes) implanted with ICL (V4c) and categorized them into incremental groups according to pupil diameter. Preoperative and postoperative photopic and mesopic pupil diameter, uncorrected distance visual acuity (UDVA), and QoV questionnaire scores were assessed and compared. Postoperatively, at 3 months, UDVA was -0.10 +/- 0.06 logarithm of the minimum angle of resolution (LogMAR), and mean QoV for day and night was 9.34 +/- 0.76 and 8.58 +/- 1.29, respectively. The mean mesopic and photopic pupil diameters were 6.59 +/- 0.79mm and 4.61 +/- 0.74mm, respectively. Photopic pupil diameter negatively correlated with "QoV day" (R-s = -0.413, P = .001), positively correlated with "haloes" (R-s = 0.568*, P < .001) and "blurred vision" (R-s = 0.243, P = .04) respectively. Mesopic pupil diameter negatively correlated with "QoV night" (R-s = -0.426, P = .001), positively correlated with "haloes" (R-s = 0.624*, P < .001), "starburst" (R-s = 0.233, P = .046) and "difficulty focusing" (R-s = 0.27, P = .025), respectively. Participants had excellent VA at 3-month follow-up. Photopic and mesonic pupil diameter negatively correlated with QoV day and QoV night scores, respectively. Pupil diameter was found to have a more significant effect on visual symptoms at night, and lower QoV due to larger pupil size was more noticeable at night. Further investigation is needed to explore the importance of pupil diameter and its impact on the QoV in ICL implanted patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] One-year Observation of Safety of Implantable Collamer Lens V4c Implantation Without Using an Ophthalmic Viscosurgical Device
    Chen, Zhuoyi
    Niu, Lingling
    Zhao, Jing
    Yao, Peijun
    Wang, Xiaoying
    Zhou, Xingtao
    FRONTIERS IN MEDICINE, 2022, 9
  • [42] Comprehensive assessment of corneal microstructural changes following V4c implantable collamer lens surgery using in vivo confocal microscopy
    Wei, Qiaoling
    Chang, Weiteng
    Jiang, Rui
    Zhou, Xingtao
    Yu, Zhiqiang
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [43] Endothelial cell loss post-implantable collamer lens V4c: meta-analysis
    Kisiel, Filip Blazej
    Gurumurthy, Gerard Jonathan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (04): : 420 - 423
  • [44] Vault-correlated efficacy and safety of Implantable Collamer Lens V4c implantation for myopia in patients with shallow anterior chamber depth
    Qian, Tianwei
    Du, Jingxiao
    Ren, Ruixia
    Zhou, Hao
    Li, Haiyan
    Zhang, Zhihua
    Xu, Xun
    OPHTHALMIC RESEARCH, 2023, : 445 - 456
  • [45] Rotational Stability and Outcomes of V4c Toric Implantable Collamer Lenses Placed at Different Lens Orientations
    Yang, Yukun
    Zhu, Fengjiao
    Ma, Yiping
    Li, Jing
    Li, Xiaoxi
    Yao, Xiaoming
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (01) : e29 - e38
  • [46] Long-Term Outcomes of Retinal Detachment in Phakic Eyes After Implantation of Implantable Collamer Lens V4c for High Myopia Correction
    Xu, Weiwei
    Song, Zhou
    Huang, Yifei
    Tao, Ye
    Wang, Junqing
    Wang, Liqiang
    Li, Zhaohui
    FRONTIERS IN MEDICINE, 2020, 7
  • [47] Efficacy and Safety of Implantable Collamer Lens V4c Implantation in 1,834 Myopic Eyes for 1 Year of Follow-up
    Du, Jingxiao
    Zhou, Wenkai
    Zhao, Ting
    Qian, Tianwei
    Lu, Yi
    Li, Haiyan
    Zhang, Zhihua
    Lian, Jingcai
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (10) : 694 - 704
  • [48] Binocular imbalance in patients after implantable collamer lens V4c implantation or femtosecond laser-assisted in situ keratomileusis for myopia with presbyopia
    Ye, Yuhao
    Zhang, Zhe
    Niu, Lingling
    Shi, Wanru
    Wang, Xiaoying
    Yan, Li
    Zhou, Xingtao
    Zhao, Jing
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [49] Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia
    Ye, Yuhao
    Zhao, Jing
    Zhang, Zhe
    Niu, Lingling
    Shi, Wanru
    Wang, Xiaoying
    Zhou, Xingtao
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (08) : 2763 - 2771
  • [50] One-year natural course of corneal densitometry in high myopic patients after implantation of an implantable collamer lens (model V4c)
    Xun Chen
    Yang Shen
    Haipeng Xu
    Xiaoying Wang
    Xingtao Zhou
    BMC Ophthalmology, 20