The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation An observational study

被引:4
|
作者
Zhang, Qing
Wu, Yi [1 ,2 ]
Huang, He [1 ]
Qin, Guanghao [1 ]
Li, Liangzhe [1 ]
Chen, Jiayan [1 ]
Che, Huixin [1 ]
Xu, Ling [1 ]
Moore, Jonathan E. [3 ]
He, Wei [1 ]
Yu, Sile [1 ]
Pazo, Emmanuel Eric [1 ]
He, Xingru [1 ]
机构
[1] He Eye Specialist Hosp, Shenyang, Peoples R China
[2] Dalian Med Univ, Affiliated Hosp 2, Dalian, Peoples R China
[3] Cathedral Eye Clin, Belfast, Antrim, North Ireland
关键词
implantable collamer lens; phakic intraocular lens; pupil size; quality of vision; HIGH MYOPIA; SIZE; MANAGEMENT; LASIK;
D O I
10.1097/MD.0000000000035198
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to assess the change in pupil size and its influence on subjective quality of vision (QoV) in subjects with implanted collamer lenses (ICLs). This retrospective study assessed 53 participants (53 eyes) implanted with ICL (V4c) and categorized them into incremental groups according to pupil diameter. Preoperative and postoperative photopic and mesopic pupil diameter, uncorrected distance visual acuity (UDVA), and QoV questionnaire scores were assessed and compared. Postoperatively, at 3 months, UDVA was -0.10 +/- 0.06 logarithm of the minimum angle of resolution (LogMAR), and mean QoV for day and night was 9.34 +/- 0.76 and 8.58 +/- 1.29, respectively. The mean mesopic and photopic pupil diameters were 6.59 +/- 0.79mm and 4.61 +/- 0.74mm, respectively. Photopic pupil diameter negatively correlated with "QoV day" (R-s = -0.413, P = .001), positively correlated with "haloes" (R-s = 0.568*, P < .001) and "blurred vision" (R-s = 0.243, P = .04) respectively. Mesopic pupil diameter negatively correlated with "QoV night" (R-s = -0.426, P = .001), positively correlated with "haloes" (R-s = 0.624*, P < .001), "starburst" (R-s = 0.233, P = .046) and "difficulty focusing" (R-s = 0.27, P = .025), respectively. Participants had excellent VA at 3-month follow-up. Photopic and mesonic pupil diameter negatively correlated with QoV day and QoV night scores, respectively. Pupil diameter was found to have a more significant effect on visual symptoms at night, and lower QoV due to larger pupil size was more noticeable at night. Further investigation is needed to explore the importance of pupil diameter and its impact on the QoV in ICL implanted patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] A four-year observation of corneal densitometry after implantable collamer lens V4c implantation
    Zhao, Jing
    Yang, Wen
    Zhao, Jiao
    Shen, Yang
    Sun, Ling
    Han, Tian
    Wang, Xiaoying
    Yao, Peijun
    Zhou, Xingtao
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (07)
  • [22] Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens
    Min Ji Park
    Hye Min Jeon
    Kyoung Heon Lee
    Sang Youp Han
    International Journal of Ophthalmology, 2017, (04) : 619 - 623
  • [23] Visual outcomes and corneal biomechanics after V4c implantable collamer lens implantation in subclinical keratoconus
    Li, Kangjun
    Wang, Zheng
    Zhang, Dexiu
    Wang, Shanshan
    Song, Xiaocui
    Li, Yaxin
    Wang, Ming X.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (10): : 1339 - 1345
  • [24] Implantable collamer lens V4b and V4c for correction of high myopia
    Bhandari, Vipul
    Karandikar, Smitha
    Reddy, Jagdeesh K.
    Relekar, Kirti
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2015, 27 (3-4): : 76 - 81
  • [25] Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c
    Lin, I. -Chun
    Jiang, Yinjie
    Cheng, Mingrui
    Li, Boliang
    Lei, Yadi
    Xu, Guanghan
    Li, Mingwei
    Mao, Zhiwei
    Rui, Ning
    Chen, Xun
    Wang, Xiaoying
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 733 - 745
  • [26] Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT
    Liu, Fang
    Xia, Fei
    Niu, Lingling
    Zhao, Jing
    Wang, Xiaoying
    Zhou, Xingtao
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (11):
  • [27] One-year visual outcomes and optical quality of femtosecond laser small incision lenticule extraction and Visian Implantable Collamer Lens (ICL V4c) implantation for high myopia
    Niu, Lingling
    Miao, Huamao
    Tian, Mi
    Fu, Dan
    Wang, Xiaoying
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2020, 98 (06) : E662 - E667
  • [28] Corneal Aberrometic changes after ICL V4C intraocular lens implantation
    Garcia Padilla, Luis Antonio
    Vera-Duarte, Guillermo Raul
    Ramirez-Miranda, Arturo J.
    Kahuam-Lopez, Nicolas
    Haro-Morlett, Luis
    Graue-Hernandez, Enrique O.
    Navas, Alejandro
    Muller Morales, Adolfo
    Rubio, Gustavo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [29] Safety and efficacy of toric implantable collamer lens V4c model - A retrospective South Indian study
    Chaitanya, S. Ravi
    Anitha, Venugopal
    Ravindran, Meenakshi
    Ghorpade, Aditya
    Rengappa, Ramakrishnan
    Uduman, Mahammed Sithiq
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) : 3006 - 3011
  • [30] Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
    Nie, Danyao
    Yan, Pisong
    Yan, Zonghui
    Zhang, Jing
    He, Wenling
    Li, Ming
    Sun, Liangnan
    Huang, Mingquan
    Liu, Xinhua
    Lin, Haotian
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (02)