The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation An observational study

被引:4
|
作者
Zhang, Qing
Wu, Yi [1 ,2 ]
Huang, He [1 ]
Qin, Guanghao [1 ]
Li, Liangzhe [1 ]
Chen, Jiayan [1 ]
Che, Huixin [1 ]
Xu, Ling [1 ]
Moore, Jonathan E. [3 ]
He, Wei [1 ]
Yu, Sile [1 ]
Pazo, Emmanuel Eric [1 ]
He, Xingru [1 ]
机构
[1] He Eye Specialist Hosp, Shenyang, Peoples R China
[2] Dalian Med Univ, Affiliated Hosp 2, Dalian, Peoples R China
[3] Cathedral Eye Clin, Belfast, Antrim, North Ireland
关键词
implantable collamer lens; phakic intraocular lens; pupil size; quality of vision; HIGH MYOPIA; SIZE; MANAGEMENT; LASIK;
D O I
10.1097/MD.0000000000035198
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to assess the change in pupil size and its influence on subjective quality of vision (QoV) in subjects with implanted collamer lenses (ICLs). This retrospective study assessed 53 participants (53 eyes) implanted with ICL (V4c) and categorized them into incremental groups according to pupil diameter. Preoperative and postoperative photopic and mesopic pupil diameter, uncorrected distance visual acuity (UDVA), and QoV questionnaire scores were assessed and compared. Postoperatively, at 3 months, UDVA was -0.10 +/- 0.06 logarithm of the minimum angle of resolution (LogMAR), and mean QoV for day and night was 9.34 +/- 0.76 and 8.58 +/- 1.29, respectively. The mean mesopic and photopic pupil diameters were 6.59 +/- 0.79mm and 4.61 +/- 0.74mm, respectively. Photopic pupil diameter negatively correlated with "QoV day" (R-s = -0.413, P = .001), positively correlated with "haloes" (R-s = 0.568*, P < .001) and "blurred vision" (R-s = 0.243, P = .04) respectively. Mesopic pupil diameter negatively correlated with "QoV night" (R-s = -0.426, P = .001), positively correlated with "haloes" (R-s = 0.624*, P < .001), "starburst" (R-s = 0.233, P = .046) and "difficulty focusing" (R-s = 0.27, P = .025), respectively. Participants had excellent VA at 3-month follow-up. Photopic and mesonic pupil diameter negatively correlated with QoV day and QoV night scores, respectively. Pupil diameter was found to have a more significant effect on visual symptoms at night, and lower QoV due to larger pupil size was more noticeable at night. Further investigation is needed to explore the importance of pupil diameter and its impact on the QoV in ICL implanted patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Buffering zone of implantable Collamer lens sizing in V4c
    Seung Wan Nam
    Dong Hui Lim
    Joo Hyun
    Eui-Sang Chung
    Tae-Young Chung
    BMC Ophthalmology, 17
  • [12] Four-year visual outcomes and optical quality of SMILE and implantable collamer lens V4c (EVO-ICL) implantation for high myopia: a retrospective study
    Luo, Wuqiang
    Aruma, Aruma
    Li, Meiyan
    Wang, Jing
    Xie, Jing
    Xiao, Xin
    Shen, Yang
    Niu, Lingling
    Wang, Xiaoying
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [13] Four-year visual outcomes and optical quality of SMILE and implantable collamer lens V4c (EVO-ICL) implantation for high myopia: a retrospective study
    Wuqiang Luo
    Aruma Aruma
    Meiyan Li
    Jing Wang
    Jing Xie
    Xin Xiao
    Yang Shen
    Lingling Niu
    Xiaoying Wang
    Xingtao Zhou
    BMC Ophthalmology, 23
  • [14] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Lin, Qinghong
    Yang, Dong
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [15] Evaluation of Disk Halo Size after Implantation of a Collamer Lens with a Central Hole (ICL V4c)
    Chen, Xun
    Han, Tian
    Zhao, Feng
    Miao, Huamao
    Wang, Xiaoying
    Zhou, Xingtao
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [16] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Qinghong Lin
    Dong Yang
    Xingtao Zhou
    BMC Ophthalmology, 22
  • [17] The influence of iris -ciliary angle (ICA) on the vault after implantation of V4c implantable collamer lens: a chain mediation model of ICL haptic related factors
    Tan, Weina
    Wang, Zheng
    Zeng, Qingyan
    Lei, Xiaohua
    Pan, Chao
    Shu, Bao
    Jin, Lina
    Chen, Qian
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [18] The influence of iris -ciliary angle (ICA) on the vault after implantation of V4c implantable collamer lens: a chain mediation model of ICL haptic related factors
    Weina Tan
    Zheng Wang
    Qingyan Zeng
    Xiaohua Lei
    Chao Pan
    Bao Shu
    Lina Jin
    Qian Chen
    BMC Ophthalmology, 23
  • [19] Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens
    Park, Min Ji
    Jeon, Hye Min
    Lee, Kyoung Heon
    Han, Sang Youp
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (04) : 619 - 623
  • [20] Analysis of Inter-Eye Vault Differences After Implantable Collamer Lens (V4c) Implantation
    Tan, Xin
    Liu, Wenjie
    Chang, Ying
    Wu, Wanmin
    Yang, Lichun
    Liu, Jiewei
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2023, 16 : 2451 - 2459