Evaluation of Disk Halo Size after Implantation of a Collamer Lens with a Central Hole (ICL V4c)

被引:13
|
作者
Chen, Xun [1 ,2 ,3 ]
Han, Tian [1 ,2 ,3 ]
Zhao, Feng [1 ,2 ,3 ,4 ]
Miao, Huamao [1 ,2 ,3 ]
Wang, Xiaoying [1 ,2 ,3 ]
Zhou, Xingtao [1 ,2 ,3 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[2] Fudan Univ, NHC Key Lab Myopia, Shanghai, Peoples R China
[3] Res Ctr Ophthalmol & Optometry Shanghai, Shanghai, Peoples R China
[4] Shanghai Univ Tradit Chinese Med, Shuguang Hosp, Dept Ophthalmol, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
PHAKIC INTRAOCULAR-LENS; PUPIL DIAMETER CHANGES; OPTICAL-QUALITY; SCATTERING; MODERATE; VAULT; LIGHT; IRIS;
D O I
10.1155/2019/7174913
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To investigate disk halo size changes produced by a glare source after surgical insertion of an implantable collamer lens with a central hole (ICL V4c) for myopia correction. Methods. In this prospective study, disk halo size and pupillary light response with a vision monitor were measured preoperatively and at 1 week, 1 month, and 3 months postoperatively. Pupillary light response parameters included contraction amplitude, latency, duration, and velocity; dilation latency, duration, and velocity; and initial, maximum, minimum, and average pupil diameters. Results. Forty-two right eyes of 42 patients were enrolled. Postoperative uncorrected distance visual acuity was better than or equal to 20/20 in all eyes. Compared to preoperative values, disk halo size showed no significant difference at 1 week postoperatively (P > 0.05) and then decreased significantly at 1 and 3 months postoperatively (both P < 0.001). Contraction amplitude and velocity, as well as dilation velocity, decreased significantly at all postoperative time points (all P < 0.001). Disk halo size at 3months postoperatively was significantly correlated with initial (r = 0.446, P = 0.003), maximum (r = 0.483, P = 0.001), minimum (r = 0.425, P = 0.005), and average pupil diameters (r = 0.474, P = 0.002). Conclusions. After ICL V4c implantation, disk halo size was reduced in the short term. Patients with smaller pupil sizes during pupillary response to light experienced smaller halos after ICL V4c implantation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c)
    Huamao Miao
    Xun Chen
    Mi Tian
    Yingjun Chen
    Xiaoying Wang
    Xingtao Zhou
    BMC Ophthalmology, 18
  • [2] Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c)
    Miao, Huamao
    Chen, Xun
    Tian, Mi
    Chen, Yingjun
    Wang, Xiaoying
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2018, 18
  • [3] Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
    Chen, Xun
    Miao, Huamao
    Naidu, Rajeev Krishnan
    Wang, Xiaoying
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2016, 16
  • [4] Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
    Xun Chen
    Huamao Miao
    Rajeev Krishnan Naidu
    Xiaoying Wang
    Xingtao Zhou
    BMC Ophthalmology, 16
  • [5] Corneal Aberrometic changes after ICL V4C intraocular lens implantation
    Garcia Padilla, Luis Antonio
    Vera-Duarte, Guillermo Raul
    Ramirez-Miranda, Arturo J.
    Kahuam-Lopez, Nicolas
    Haro-Morlett, Luis
    Graue-Hernandez, Enrique O.
    Navas, Alejandro
    Muller Morales, Adolfo
    Rubio, Gustavo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [6] Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c
    Lin, I. -Chun
    Jiang, Yinjie
    Cheng, Mingrui
    Li, Boliang
    Lei, Yadi
    Xu, Guanghan
    Li, Mingwei
    Mao, Zhiwei
    Rui, Ning
    Chen, Xun
    Wang, Xiaoying
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 733 - 745
  • [7] Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
    He, Tianrui
    Zhu, Yi
    Zhou, Jibo
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [8] Comparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia A cohort study
    Tian, Ying
    Jiang, Hai-Bo
    Jiang, Jian
    Wen, Dan
    Xia, Xiao-Bo
    Song, Wei-Tao
    MEDICINE, 2017, 96 (25)
  • [9] Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
    Tianrui He
    Yi Zhu
    Jibo Zhou
    BMC Ophthalmology, 20
  • [10] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Lin, Qinghong
    Yang, Dong
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2022, 22 (01)