The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation An observational study

被引:4
|
作者
Zhang, Qing
Wu, Yi [1 ,2 ]
Huang, He [1 ]
Qin, Guanghao [1 ]
Li, Liangzhe [1 ]
Chen, Jiayan [1 ]
Che, Huixin [1 ]
Xu, Ling [1 ]
Moore, Jonathan E. [3 ]
He, Wei [1 ]
Yu, Sile [1 ]
Pazo, Emmanuel Eric [1 ]
He, Xingru [1 ]
机构
[1] He Eye Specialist Hosp, Shenyang, Peoples R China
[2] Dalian Med Univ, Affiliated Hosp 2, Dalian, Peoples R China
[3] Cathedral Eye Clin, Belfast, Antrim, North Ireland
关键词
implantable collamer lens; phakic intraocular lens; pupil size; quality of vision; HIGH MYOPIA; SIZE; MANAGEMENT; LASIK;
D O I
10.1097/MD.0000000000035198
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to assess the change in pupil size and its influence on subjective quality of vision (QoV) in subjects with implanted collamer lenses (ICLs). This retrospective study assessed 53 participants (53 eyes) implanted with ICL (V4c) and categorized them into incremental groups according to pupil diameter. Preoperative and postoperative photopic and mesopic pupil diameter, uncorrected distance visual acuity (UDVA), and QoV questionnaire scores were assessed and compared. Postoperatively, at 3 months, UDVA was -0.10 +/- 0.06 logarithm of the minimum angle of resolution (LogMAR), and mean QoV for day and night was 9.34 +/- 0.76 and 8.58 +/- 1.29, respectively. The mean mesopic and photopic pupil diameters were 6.59 +/- 0.79mm and 4.61 +/- 0.74mm, respectively. Photopic pupil diameter negatively correlated with "QoV day" (R-s = -0.413, P = .001), positively correlated with "haloes" (R-s = 0.568*, P < .001) and "blurred vision" (R-s = 0.243, P = .04) respectively. Mesopic pupil diameter negatively correlated with "QoV night" (R-s = -0.426, P = .001), positively correlated with "haloes" (R-s = 0.624*, P < .001), "starburst" (R-s = 0.233, P = .046) and "difficulty focusing" (R-s = 0.27, P = .025), respectively. Participants had excellent VA at 3-month follow-up. Photopic and mesonic pupil diameter negatively correlated with QoV day and QoV night scores, respectively. Pupil diameter was found to have a more significant effect on visual symptoms at night, and lower QoV due to larger pupil size was more noticeable at night. Further investigation is needed to explore the importance of pupil diameter and its impact on the QoV in ICL implanted patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Cao, Weifang
    Zhang, Suhua
    Liu, Qian
    Zhou, Jing
    Yuan, Xiaoyong
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (11) : 4111 - 4120
  • [32] Effects of Decentration of Implantable Collamer Lens V4c on Visual Quality With the OPD-Scan III Aberrometer
    Chen, Xun
    Lin, I-chun
    Miao, Huamao
    Cheng, Mingrui
    Li, Boliang
    Jiang, Yinjie
    Lei, Yadi
    Wang, Xiaoying
    Zhou, Xingtao
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 259 : 88 - 95
  • [33] Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
    He, Tianrui
    Zhu, Yi
    Zhou, Jibo
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [34] The Relationship between Anterior Chamber Angle and Intraocular Pressure Early after V4c Implantable Collamer Lens Implantation
    Hu, Zongli
    Chen, Chunlin
    Sun, Min
    Yuan, Rongdi
    Ye, Jian
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [35] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Weifang Cao
    Suhua Zhang
    Qian Liu
    Jing Zhou
    Xiaoyong Yuan
    International Ophthalmology, 2023, 43 : 4111 - 4120
  • [36] Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
    Tianrui He
    Yi Zhu
    Jibo Zhou
    BMC Ophthalmology, 20
  • [37] Comparison of Visual Outcomes and Optical Quality of Femtosecond Laser-Assisted SMILE and Visian Implantable Collamer Lens (ICL V4c) Implantation for Moderate to High Myopia: A Meta-analysis
    Chen, Di
    Zhao, Xinyu
    Chou, Yuyu
    Luo, Yan
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (06) : 332 - +
  • [38] Outcomes of implantable collamer lens v4 and v4c for correction of high myopia - a case series
    Karandikar, Smita
    Bhandari, Vipul
    Reddy, Jagdeesh
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2015, 7 (02) : 164 - 172
  • [39] Clinical Observation of Posterior-Chamber Phakic Implantable Collamer Lens V4c Implantation in Myopic Patients with Shallow Anterior Chamber Depth: A Retrospective, Consecutive Observational Study
    Yuan, Juan
    Wu, Shuang
    Hu, Zongli
    Chen, Chunlin
    Ye, Shiyang
    Ye, Jian
    JOURNAL OF OPHTHALMOLOGY, 2024, 2024
  • [40] Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients-A 1-Year Follow-Up Study
    Wei, Qiaoling
    Zhou, Xianjin
    Chang, Weiteng
    Jiang, Rui
    Zhou, Xingtao
    Yu, Zhiqiang
    DIAGNOSTICS, 2023, 13 (19)