Vault-correlated efficacy and safety of Implantable Collamer Lens V4c implantation for myopia in patients with shallow anterior chamber depth

被引:8
|
作者
Qian, Tianwei [1 ,2 ,3 ,4 ,5 ]
Du, Jingxiao [1 ,2 ,3 ,4 ,5 ]
Ren, Ruixia [6 ]
Zhou, Hao [1 ,2 ,3 ,4 ,5 ]
Li, Haiyan [6 ]
Zhang, Zhihua [1 ,2 ,3 ,4 ,5 ,7 ]
Xu, Xun [1 ,2 ,3 ,4 ,5 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[2] Natl Clin Res Ctr Eye Dis, Shanghai, Peoples R China
[3] Shanghai Key Lab Ocular Fundus Dis, Shanghai, Peoples R China
[4] Shanghai Engn Ctr Visual Sci & Photomed, Shanghai, Peoples R China
[5] Shanghai Engn Ctr Precise Diag & Treatment Eye Dis, Shanghai, Peoples R China
[6] Shanghai Xinshijie Zhongxing Eye Hosp, 1618 Zhongxing Rd, Shanghai 200070, Peoples R China
[7] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, 100 Haining Rd, Shanghai 200080, Peoples R China
基金
中国国家自然科学基金;
关键词
PHAKIC INTRAOCULAR-LENS; CONTACT-LENS; FOLLOW-UP; MODERATE; ANGLE; CATARACT; MODELS; LENGTH; EYES;
D O I
10.1159/000528616
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: To evaluate efficacy and safety outcomes after implantation of the Visian Implantable Collamer Lens (ICL V4c) in myopia patients with shallow anterior chamber depth (ACD).Methods: This retrospective study followed 163 eyes of 94 patients for at least 24 months. Uncorrected distance visual acuity, corrected distance visual acuity, intraocular pressure (IOP), manifest refraction, vault, endothelial cell density (ECD), anterior chamber angle (ACA), anterior chamber volume (ACV) and the distance from the corneal endothelium to the central ICL (C-ICL) were measured during follow-ups. Spearman's correlation and logistic regression were used to identify variables correlated with changes in ECD and potential risk factors for ineffective outcomes, respectively.Results: All surgeries were performed safely. High IOP of 9 eyes and anterior capsular opacity of 5 eyes were observed. The last follow-up ACA had a significant difference between the high and normal IOP groups (P = 0.0003). The mean ECD and vault was 2855.76 +/- 270.82 cells/mm2 and 388.01 +/- 135.28 mu m at the last follow-up, respectively. The vault and C-ICL were significantly associated with Delta ECD (all P < 0.01). Furthermore, the vault was most responsible for the ECD loss. Twenty-two eyes had unsatisfactory postoperative UDVA, and the low vault at the last follow-up was a significant risk factor for this ineffective outcome (P < 0.001, OR = 14.739).Conclusions: ICL V4c implantation in patients with shallow ACD achieved stable visual outcomes. The vault is related to postoperative visual acuity and ECD loss, which needs to be paid attention during follow-up.
引用
收藏
页码:445 / 456
页数:22
相关论文
共 50 条
  • [1] Clinical Observation of Posterior-Chamber Phakic Implantable Collamer Lens V4c Implantation in Myopic Patients with Shallow Anterior Chamber Depth: A Retrospective, Consecutive Observational Study
    Yuan, Juan
    Wu, Shuang
    Hu, Zongli
    Chen, Chunlin
    Ye, Shiyang
    Ye, Jian
    JOURNAL OF OPHTHALMOLOGY, 2024, 2024
  • [2] Analysis of Inter-Eye Vault Differences After Implantable Collamer Lens (V4c) Implantation
    Tan, Xin
    Liu, Wenjie
    Chang, Ying
    Wu, Wanmin
    Yang, Lichun
    Liu, Jiewei
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2023, 16 : 2451 - 2459
  • [3] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Lin, Qinghong
    Yang, Dong
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [4] The Relationship between Anterior Chamber Angle and Intraocular Pressure Early after V4c Implantable Collamer Lens Implantation
    Hu, Zongli
    Chen, Chunlin
    Sun, Min
    Yuan, Rongdi
    Ye, Jian
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [5] Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer lens V4c implantation in patients with high myopia
    Garcia-De la Rosa, Guillermo
    Olivo-Payne, Andrew
    Carlos Serna-Ojeda, Juan
    Sandra Salazar-Ramos, Maria
    Lichtinger, Alejandro
    Gomez-Bastar, Arturo
    Ramirez-Miranda, Arturo
    Navas, Alejandro
    Graue-Hernandez, Enrique O.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (04) : 544 - 548
  • [6] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Qinghong Lin
    Dong Yang
    Xingtao Zhou
    BMC Ophthalmology, 22
  • [7] Implantable collamer lens V4b and V4c for correction of high myopia
    Bhandari, Vipul
    Karandikar, Smitha
    Reddy, Jagdeesh K.
    Relekar, Kirti
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2015, 27 (3-4): : 76 - 81
  • [8] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Cao, Weifang
    Zhang, Suhua
    Liu, Qian
    Zhou, Jing
    Yuan, Xiaoyong
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (11) : 4111 - 4120
  • [9] Long-term evaluation of anterior lens density after implantable collamer lens V4c implantation in patients with myopia over 40 years old
    Ye, Yuhao
    Zhao, Jing
    Niu, Lingling
    Shi, Wanru
    Wang, Xiaoying
    Zhou, Xingtao
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (11) : 1508 - 1513
  • [10] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Weifang Cao
    Suhua Zhang
    Qian Liu
    Jing Zhou
    Xiaoyong Yuan
    International Ophthalmology, 2023, 43 : 4111 - 4120