Vault-correlated efficacy and safety of Implantable Collamer Lens V4c implantation for myopia in patients with shallow anterior chamber depth

被引:8
|
作者
Qian, Tianwei [1 ,2 ,3 ,4 ,5 ]
Du, Jingxiao [1 ,2 ,3 ,4 ,5 ]
Ren, Ruixia [6 ]
Zhou, Hao [1 ,2 ,3 ,4 ,5 ]
Li, Haiyan [6 ]
Zhang, Zhihua [1 ,2 ,3 ,4 ,5 ,7 ]
Xu, Xun [1 ,2 ,3 ,4 ,5 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[2] Natl Clin Res Ctr Eye Dis, Shanghai, Peoples R China
[3] Shanghai Key Lab Ocular Fundus Dis, Shanghai, Peoples R China
[4] Shanghai Engn Ctr Visual Sci & Photomed, Shanghai, Peoples R China
[5] Shanghai Engn Ctr Precise Diag & Treatment Eye Dis, Shanghai, Peoples R China
[6] Shanghai Xinshijie Zhongxing Eye Hosp, 1618 Zhongxing Rd, Shanghai 200070, Peoples R China
[7] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, 100 Haining Rd, Shanghai 200080, Peoples R China
基金
中国国家自然科学基金;
关键词
PHAKIC INTRAOCULAR-LENS; CONTACT-LENS; FOLLOW-UP; MODERATE; ANGLE; CATARACT; MODELS; LENGTH; EYES;
D O I
10.1159/000528616
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: To evaluate efficacy and safety outcomes after implantation of the Visian Implantable Collamer Lens (ICL V4c) in myopia patients with shallow anterior chamber depth (ACD).Methods: This retrospective study followed 163 eyes of 94 patients for at least 24 months. Uncorrected distance visual acuity, corrected distance visual acuity, intraocular pressure (IOP), manifest refraction, vault, endothelial cell density (ECD), anterior chamber angle (ACA), anterior chamber volume (ACV) and the distance from the corneal endothelium to the central ICL (C-ICL) were measured during follow-ups. Spearman's correlation and logistic regression were used to identify variables correlated with changes in ECD and potential risk factors for ineffective outcomes, respectively.Results: All surgeries were performed safely. High IOP of 9 eyes and anterior capsular opacity of 5 eyes were observed. The last follow-up ACA had a significant difference between the high and normal IOP groups (P = 0.0003). The mean ECD and vault was 2855.76 +/- 270.82 cells/mm2 and 388.01 +/- 135.28 mu m at the last follow-up, respectively. The vault and C-ICL were significantly associated with Delta ECD (all P < 0.01). Furthermore, the vault was most responsible for the ECD loss. Twenty-two eyes had unsatisfactory postoperative UDVA, and the low vault at the last follow-up was a significant risk factor for this ineffective outcome (P < 0.001, OR = 14.739).Conclusions: ICL V4c implantation in patients with shallow ACD achieved stable visual outcomes. The vault is related to postoperative visual acuity and ECD loss, which needs to be paid attention during follow-up.
引用
收藏
页码:445 / 456
页数:22
相关论文
共 50 条
  • [41] Four-year observation of the changes in corneal endothelium cell density and correlated factors after Implantable Collamer Lens V4c implantation
    Yang, Wen
    Zhao, Jing
    Sun, Ling
    Zhao, Jiao
    Niu, Lingling
    Wang, Xiaoying
    Zhou, Xingtao
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2021, 105 (05) : 625 - 630
  • [42] Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients-A 1-Year Follow-Up Study
    Wei, Qiaoling
    Zhou, Xianjin
    Chang, Weiteng
    Jiang, Rui
    Zhou, Xingtao
    Yu, Zhiqiang
    DIAGNOSTICS, 2023, 13 (19)
  • [43] Angle and Vault Changes in patients with high myopia after ICL V4c Implantation.
    Salazar, Sandra
    Garcia, Guillermo
    Gomez, Arturo
    Ramirez-Miranda, Arturo J.
    Navas, Alejandro
    Graue, Enrique O.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [44] The influence of iris -ciliary angle (ICA) on the vault after implantation of V4c implantable collamer lens: a chain mediation model of ICL haptic related factors
    Tan, Weina
    Wang, Zheng
    Zeng, Qingyan
    Lei, Xiaohua
    Pan, Chao
    Shu, Bao
    Jin, Lina
    Chen, Qian
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [45] The influence of iris -ciliary angle (ICA) on the vault after implantation of V4c implantable collamer lens: a chain mediation model of ICL haptic related factors
    Weina Tan
    Zheng Wang
    Qingyan Zeng
    Xiaohua Lei
    Chao Pan
    Bao Shu
    Lina Jin
    Qian Chen
    BMC Ophthalmology, 23
  • [46] Combined intacs and posterior chamber toric Implantable collamer lens implantation for keratoconic patients with extreme myopia
    Coskunseven, Efekan
    Onder, Methiye
    Kymionis, George D.
    Diakonis, Vasilios F.
    Arslan, Ebru
    Tsiklis, Nikolaos
    Bouzoukis, Dimitrios I.
    Pallikaris, Ioannis
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (03) : 387 - 389
  • [47] Ten-Year Clinical Outcomes of V4c Implantable Collamer Lens Implantation: Longitudinal Analysis of Visual Acuity, Endothelial Cell Density, and Vault Dynamics
    Chung, Byunghoon
    Choi, Jin young
    Kang, David S. Y.
    Kim, Kangyoon
    Kim, Bo Yi
    Kim, Tae-Im
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2025, 269 : 1 - 10
  • [48] Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
    Nie, Danyao
    Yan, Pisong
    Yan, Zonghui
    Zhang, Jing
    He, Wenling
    Li, Ming
    Sun, Liangnan
    Huang, Mingquan
    Liu, Xinhua
    Lin, Haotian
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (02)
  • [49] Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens
    Park, Min Ji
    Jeon, Hye Min
    Lee, Kyoung Heon
    Han, Sang Youp
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (04) : 619 - 623
  • [50] Comparison of objective and subjective visual quality early after implantable collamer lens V4c (ICL V4c) and small incision lenticule extraction (SMILE) for high myopia correction
    Wei, Ruoyan
    Li, Meiyan
    Zhang, Huihui
    Aruma, Aruma
    Miao, Huamao
    Wang, Xiaoying
    Zhou, Jin
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2020, 98 (08) : E943 - E950