Vault-correlated efficacy and safety of Implantable Collamer Lens V4c implantation for myopia in patients with shallow anterior chamber depth

被引:8
|
作者
Qian, Tianwei [1 ,2 ,3 ,4 ,5 ]
Du, Jingxiao [1 ,2 ,3 ,4 ,5 ]
Ren, Ruixia [6 ]
Zhou, Hao [1 ,2 ,3 ,4 ,5 ]
Li, Haiyan [6 ]
Zhang, Zhihua [1 ,2 ,3 ,4 ,5 ,7 ]
Xu, Xun [1 ,2 ,3 ,4 ,5 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[2] Natl Clin Res Ctr Eye Dis, Shanghai, Peoples R China
[3] Shanghai Key Lab Ocular Fundus Dis, Shanghai, Peoples R China
[4] Shanghai Engn Ctr Visual Sci & Photomed, Shanghai, Peoples R China
[5] Shanghai Engn Ctr Precise Diag & Treatment Eye Dis, Shanghai, Peoples R China
[6] Shanghai Xinshijie Zhongxing Eye Hosp, 1618 Zhongxing Rd, Shanghai 200070, Peoples R China
[7] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, 100 Haining Rd, Shanghai 200080, Peoples R China
基金
中国国家自然科学基金;
关键词
PHAKIC INTRAOCULAR-LENS; CONTACT-LENS; FOLLOW-UP; MODERATE; ANGLE; CATARACT; MODELS; LENGTH; EYES;
D O I
10.1159/000528616
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: To evaluate efficacy and safety outcomes after implantation of the Visian Implantable Collamer Lens (ICL V4c) in myopia patients with shallow anterior chamber depth (ACD).Methods: This retrospective study followed 163 eyes of 94 patients for at least 24 months. Uncorrected distance visual acuity, corrected distance visual acuity, intraocular pressure (IOP), manifest refraction, vault, endothelial cell density (ECD), anterior chamber angle (ACA), anterior chamber volume (ACV) and the distance from the corneal endothelium to the central ICL (C-ICL) were measured during follow-ups. Spearman's correlation and logistic regression were used to identify variables correlated with changes in ECD and potential risk factors for ineffective outcomes, respectively.Results: All surgeries were performed safely. High IOP of 9 eyes and anterior capsular opacity of 5 eyes were observed. The last follow-up ACA had a significant difference between the high and normal IOP groups (P = 0.0003). The mean ECD and vault was 2855.76 +/- 270.82 cells/mm2 and 388.01 +/- 135.28 mu m at the last follow-up, respectively. The vault and C-ICL were significantly associated with Delta ECD (all P < 0.01). Furthermore, the vault was most responsible for the ECD loss. Twenty-two eyes had unsatisfactory postoperative UDVA, and the low vault at the last follow-up was a significant risk factor for this ineffective outcome (P < 0.001, OR = 14.739).Conclusions: ICL V4c implantation in patients with shallow ACD achieved stable visual outcomes. The vault is related to postoperative visual acuity and ECD loss, which needs to be paid attention during follow-up.
引用
收藏
页码:445 / 456
页数:22
相关论文
共 50 条
  • [31] Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia
    Yuhao Ye
    Jing Zhao
    Zhe Zhang
    Lingling Niu
    Wanru Shi
    Xiaoying Wang
    Xingtao Zhou
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 2763 - 2771
  • [32] Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia
    Ye, Yuhao
    Zhao, Jing
    Zhang, Zhe
    Niu, Lingling
    Shi, Wanru
    Wang, Xiaoying
    Zhou, Xingtao
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (08) : 2763 - 2771
  • [33] Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c
    Lin, I. -Chun
    Jiang, Yinjie
    Cheng, Mingrui
    Li, Boliang
    Lei, Yadi
    Xu, Guanghan
    Li, Mingwei
    Mao, Zhiwei
    Rui, Ning
    Chen, Xun
    Wang, Xiaoying
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 733 - 745
  • [34] Long-term observation on safety and visual quality of implantable collamer lens V4c implantation for myopia correction: a 5-year follow-up
    Chen, Xiao
    Li, Li
    Rao, Jing
    Chen, Yue-Xi
    Gao, Yang
    Huang, Rui-Xue
    Zhou, Qi-Zhi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2023, 16 (07) : 1123 - 1129
  • [35] Effects of White-to-White Diameter and Anterior Chamber Depth on Implantable Collamer Lens Vault and Visual Outcome
    Seo, Je Hyun
    Kim, Mee Kum
    Wee, Won Ryang
    Lee, Jin Hak
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (08) : 730 - 738
  • [36] Long-term observation on safety and visual quality of implantable collamer lens V4c implantation for myopia correction: a 5-year follow-up
    Xiao Chen
    Li Li
    Jing Rao
    Yue-Xi Chen
    Yang Gao
    Rui-Xue Huang
    Qi-Zhi Zhou
    International Journal of Ophthalmology, 2023, (07) : 1123 - 1129
  • [37] Comparison of visual outcomes after non-toric and toric implantable collamer lens V4c for myopia and astigmatism
    Wei, Ruoyan
    Li, Meiyan
    Niu, Lingling
    Aruma, Aruma
    Miao, Huamao
    Shen, Yang
    Yao, Peijun
    Wang, Xiaoying
    Zhang, Huihui
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2021, 99 (05) : 511 - 518
  • [38] Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
    He, Tianrui
    Zhu, Yi
    Zhou, Jibo
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [39] Anterior Chamber Changes After Implantable Collamer Lens Implantation in High Myopia Using Pentacam: A Prospective Study
    Elmohamady M.N.
    Abdelghaffar W.
    Ophthalmology and Therapy, 2017, 6 (2) : 343 - 349
  • [40] Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
    Tianrui He
    Yi Zhu
    Jibo Zhou
    BMC Ophthalmology, 20