Vault-correlated efficacy and safety of Implantable Collamer Lens V4c implantation for myopia in patients with shallow anterior chamber depth

被引:8
|
作者
Qian, Tianwei [1 ,2 ,3 ,4 ,5 ]
Du, Jingxiao [1 ,2 ,3 ,4 ,5 ]
Ren, Ruixia [6 ]
Zhou, Hao [1 ,2 ,3 ,4 ,5 ]
Li, Haiyan [6 ]
Zhang, Zhihua [1 ,2 ,3 ,4 ,5 ,7 ]
Xu, Xun [1 ,2 ,3 ,4 ,5 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[2] Natl Clin Res Ctr Eye Dis, Shanghai, Peoples R China
[3] Shanghai Key Lab Ocular Fundus Dis, Shanghai, Peoples R China
[4] Shanghai Engn Ctr Visual Sci & Photomed, Shanghai, Peoples R China
[5] Shanghai Engn Ctr Precise Diag & Treatment Eye Dis, Shanghai, Peoples R China
[6] Shanghai Xinshijie Zhongxing Eye Hosp, 1618 Zhongxing Rd, Shanghai 200070, Peoples R China
[7] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, 100 Haining Rd, Shanghai 200080, Peoples R China
基金
中国国家自然科学基金;
关键词
PHAKIC INTRAOCULAR-LENS; CONTACT-LENS; FOLLOW-UP; MODERATE; ANGLE; CATARACT; MODELS; LENGTH; EYES;
D O I
10.1159/000528616
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: To evaluate efficacy and safety outcomes after implantation of the Visian Implantable Collamer Lens (ICL V4c) in myopia patients with shallow anterior chamber depth (ACD).Methods: This retrospective study followed 163 eyes of 94 patients for at least 24 months. Uncorrected distance visual acuity, corrected distance visual acuity, intraocular pressure (IOP), manifest refraction, vault, endothelial cell density (ECD), anterior chamber angle (ACA), anterior chamber volume (ACV) and the distance from the corneal endothelium to the central ICL (C-ICL) were measured during follow-ups. Spearman's correlation and logistic regression were used to identify variables correlated with changes in ECD and potential risk factors for ineffective outcomes, respectively.Results: All surgeries were performed safely. High IOP of 9 eyes and anterior capsular opacity of 5 eyes were observed. The last follow-up ACA had a significant difference between the high and normal IOP groups (P = 0.0003). The mean ECD and vault was 2855.76 +/- 270.82 cells/mm2 and 388.01 +/- 135.28 mu m at the last follow-up, respectively. The vault and C-ICL were significantly associated with Delta ECD (all P < 0.01). Furthermore, the vault was most responsible for the ECD loss. Twenty-two eyes had unsatisfactory postoperative UDVA, and the low vault at the last follow-up was a significant risk factor for this ineffective outcome (P < 0.001, OR = 14.739).Conclusions: ICL V4c implantation in patients with shallow ACD achieved stable visual outcomes. The vault is related to postoperative visual acuity and ECD loss, which needs to be paid attention during follow-up.
引用
收藏
页码:445 / 456
页数:22
相关论文
共 50 条
  • [21] Efficacy and safety after posterior chamber Implantable Collamer Lens implantation according to preoperative anterior chamber depth: Short-term comparative study
    Silva, Rui
    Franqueira, Nuno
    Faria-Correia, Fernando
    Mendes, Jose
    Oliveira, Mariana
    Monteiro, Tiago
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (02) : 822 - 830
  • [22] Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
    Chen, Xun
    Miao, Huamao
    Naidu, Rajeev Krishnan
    Wang, Xiaoying
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2016, 16
  • [23] Comparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia A cohort study
    Tian, Ying
    Jiang, Hai-Bo
    Jiang, Jian
    Wen, Dan
    Xia, Xiao-Bo
    Song, Wei-Tao
    MEDICINE, 2017, 96 (25)
  • [24] A four-year observation of corneal densitometry after implantable collamer lens V4c implantation
    Zhao, Jing
    Yang, Wen
    Zhao, Jiao
    Shen, Yang
    Sun, Ling
    Han, Tian
    Wang, Xiaoying
    Yao, Peijun
    Zhou, Xingtao
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (07)
  • [25] Visual outcomes and corneal biomechanics after V4c implantable collamer lens implantation in subclinical keratoconus
    Li, Kangjun
    Wang, Zheng
    Zhang, Dexiu
    Wang, Shanshan
    Song, Xiaocui
    Li, Yaxin
    Wang, Ming X.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (10): : 1339 - 1345
  • [26] Long-Term Outcomes of Retinal Detachment in Phakic Eyes After Implantation of Implantable Collamer Lens V4c for High Myopia Correction
    Xu, Weiwei
    Song, Zhou
    Huang, Yifei
    Tao, Ye
    Wang, Junqing
    Wang, Liqiang
    Li, Zhaohui
    FRONTIERS IN MEDICINE, 2020, 7
  • [27] Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c)
    Huamao Miao
    Xun Chen
    Mi Tian
    Yingjun Chen
    Xiaoying Wang
    Xingtao Zhou
    BMC Ophthalmology, 18
  • [28] One-year Observation of Safety of Implantable Collamer Lens V4c Implantation Without Using an Ophthalmic Viscosurgical Device
    Chen, Zhuoyi
    Niu, Lingling
    Zhao, Jing
    Yao, Peijun
    Wang, Xiaoying
    Zhou, Xingtao
    FRONTIERS IN MEDICINE, 2022, 9
  • [29] Early Assessment of Circumferential Anterior Segment Structures Following Implantable Collamer Lens V4c Implantation Via SS-OCT
    Liu, Fang
    Xia, Fei
    Niu, Lingling
    Zhao, Jing
    Wang, Xiaoying
    Zhou, Xingtao
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (11):
  • [30] Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c)
    Miao, Huamao
    Chen, Xun
    Tian, Mi
    Chen, Yingjun
    Wang, Xiaoying
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2018, 18