Experimental combustion characteristics and NOx emissions for a 600-MWe utility boiler after the retrofitted: Effects of load variation

被引:1
|
作者
Wang, Haopeng [1 ]
Deng, Shanshan [1 ]
Ti, Shuguang [1 ,5 ]
Jin, Haoze [1 ]
Yang, Zhi [1 ]
Gao, Ke [1 ]
Wu, Xuehong [2 ]
Liu, Shengyong [3 ]
An, Jingxue [4 ]
Sheng, Ranran [4 ]
机构
[1] Zhengzhou Univ Light Ind, Coll Bldg Environm Engn, Zhengzhou, Peoples R China
[2] Zhengzhou Univ Light Ind, Coll Energy & Power Engn, Zhengzhou, Peoples R China
[3] Henan Agr Univ, Coll Mech & Elect Engn, Zhengzhou, Peoples R China
[4] China Datang Corp Sci & Technol Gen Res Inst Co Lt, Zhengzhou, Peoples R China
[5] Zhengzhou Univ Light Ind, Sch Bldg Environm Engn, Zhengzhou 450002, Peoples R China
关键词
air staging; load variation; NOx emissions; swirl burner; DOWN-FIRED BOILER; NUMERICAL-SIMULATION; SWIRL BURNER; FURNACE; FLOW;
D O I
10.1002/apj.3092
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To enhance the rapid switching ability of the boiler load and reduce NOx emissions, a new combustion system was implemented in a 600-MWe wall-fired boiler with swirl burners. This system included two levels of overfire air (OFA) and low NOx combustion technology. Industrial tests were conducted at 300-, 450-, and 600-MWe loads before and after the retrofitted. These tests included measuring flue gas and furnace temperatures with thermocouples and analyzing local gas concentrations using a gas analyzer. The research results indicate that under conditions where the OFA ratio exceeds 30%, the burner exhibits good ignition performance at different loads. At the 600-MWe load, the nitrogen oxides (NOx) emissions were reduced by 55% compared to before the retrofit. After the retrofit, the flame center inside the furnace of different loads was located at the height of 33.36 m, the first and second-stage cooling water quantities were slightly higher, the reheat cooling water quantity was greatly reduced after the retrofit, and contributes to the boiler's safe operation. Under different load conditions after the retrofit, the gas temperature near the sidewall was below 850 degrees C, and the O-2 concentration near the sidewall was above 5%, effectively suppressing sidewall high-temperature corrosion and slagging.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Experimental combustion characteristics and NOx emissions at 50% of the full load for a 600-MWe utility boiler: Effects of the coal feed rate for various mills
    Ti, Shuguang
    Kuang, Min
    Wang, Haopeng
    Xu, Guangyin
    Niu, Cong
    Liu, Yannan
    Wang, Zhenfeng
    ENERGY, 2020, 196
  • [2] Improved NOx Emissions and Combustion Characteristics for a Retrofitted Down-fired 300-MWe Utility Boiler
    Li, Zhengqi
    Ren, Feng
    Chen, Zhichao
    Liu, Guangkui
    Xu, Zhenxing
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (10) : 3926 - 3931
  • [3] Combustion and NOx emission characteristics of a retrofitted down-fired 660 MWe utility boiler at different loads
    Li, Zhengqi
    Liu, Guangkui
    Zhu, Qunyi
    Chen, Zhichao
    Ren, Feng
    APPLIED ENERGY, 2011, 88 (07) : 2400 - 2406
  • [4] Influence of different swirl vane angles of over fire air on flow and combustion characteristics and NOx emissions in a 600 MWe utility boiler
    Ti, Shuguang
    Chen, Zhichao
    Li, Zhengqi
    Xie, Yiquan
    Shao, Yunlin
    Zong, Qiudong
    Zhang, Qinghua
    Zhang, Hao
    Zeng, Lingyan
    Zhu, Qunyi
    ENERGY, 2014, 74 : 775 - 787
  • [5] Asymmetric combustion characteristics and NOx emissions of a down-fired 300 MWe utility boiler at different boiler loads
    Kuang, Min
    Li, Zhengqi
    Zhang, Yan
    Chen, Xiachao
    Jia, Jinzhao
    Zhu, Qunyi
    ENERGY, 2012, 37 (01) : 580 - 590
  • [6] Industrial-scale investigations of anthracite combustion characteristics and NOx emissions in a retrofitted 300 MWe down-fired utility boiler with swirl burners
    Chen, Zhichao
    Wang, Qingxiang
    Zhang, Xiaoyan
    Zeng, Lingyan
    Zhang, Xin
    He, Tao
    Liu, Tao
    Li, Zhengqi
    APPLIED ENERGY, 2017, 202 : 169 - 177
  • [7] Effect of outer secondary air vane angles on combustion characteristics and NOx emissions for centrally fuel rich swirl burner in a 600-MWe wall-fired pulverized-coal utility boiler
    Ti, Shuguang
    Chen, Zhichao
    Li, Zhengqi
    Min, Kuang
    Zhu, Qunyi
    Chen, Lizhe
    Wang, Zhenfeng
    APPLIED THERMAL ENGINEERING, 2017, 125 : 951 - 962
  • [8] Asymmetric combustion characteristics and NOx emissions of a down-fired 300MWe utility boiler at different boiler loads
    School of Energy Science and Engineering, Harbin Institute of Technology, 92 West Dazhi Street, Harbin 150001, China
    Energy, 1600, 1 (580-590):
  • [9] Numerical optimization of combustion and NOX emission in a retrofitted 600MWe tangentially-fired boiler using lignite
    Bian, Caixia
    Huang, Junlin
    Sun, Rongyue
    APPLIED THERMAL ENGINEERING, 2023, 226
  • [10] Reducing NOx Emissions for a 600 MWe Down-Fired Pulverized-Coal Utility Boiler by Applying a Novel Combustion System
    Ma, Lun
    Fang, Qingyan
    Lv, Dangzhen
    Zhang, Cheng
    Chen, Yiping
    Chen, Gang
    Duan, Xuenong
    Wang, Xihuan
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (21) : 13040 - 13049