Experimental combustion characteristics and NOx emissions for a 600-MWe utility boiler after the retrofitted: Effects of load variation

被引:1
|
作者
Wang, Haopeng [1 ]
Deng, Shanshan [1 ]
Ti, Shuguang [1 ,5 ]
Jin, Haoze [1 ]
Yang, Zhi [1 ]
Gao, Ke [1 ]
Wu, Xuehong [2 ]
Liu, Shengyong [3 ]
An, Jingxue [4 ]
Sheng, Ranran [4 ]
机构
[1] Zhengzhou Univ Light Ind, Coll Bldg Environm Engn, Zhengzhou, Peoples R China
[2] Zhengzhou Univ Light Ind, Coll Energy & Power Engn, Zhengzhou, Peoples R China
[3] Henan Agr Univ, Coll Mech & Elect Engn, Zhengzhou, Peoples R China
[4] China Datang Corp Sci & Technol Gen Res Inst Co Lt, Zhengzhou, Peoples R China
[5] Zhengzhou Univ Light Ind, Sch Bldg Environm Engn, Zhengzhou 450002, Peoples R China
关键词
air staging; load variation; NOx emissions; swirl burner; DOWN-FIRED BOILER; NUMERICAL-SIMULATION; SWIRL BURNER; FURNACE; FLOW;
D O I
10.1002/apj.3092
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To enhance the rapid switching ability of the boiler load and reduce NOx emissions, a new combustion system was implemented in a 600-MWe wall-fired boiler with swirl burners. This system included two levels of overfire air (OFA) and low NOx combustion technology. Industrial tests were conducted at 300-, 450-, and 600-MWe loads before and after the retrofitted. These tests included measuring flue gas and furnace temperatures with thermocouples and analyzing local gas concentrations using a gas analyzer. The research results indicate that under conditions where the OFA ratio exceeds 30%, the burner exhibits good ignition performance at different loads. At the 600-MWe load, the nitrogen oxides (NOx) emissions were reduced by 55% compared to before the retrofit. After the retrofit, the flame center inside the furnace of different loads was located at the height of 33.36 m, the first and second-stage cooling water quantities were slightly higher, the reheat cooling water quantity was greatly reduced after the retrofit, and contributes to the boiler's safe operation. Under different load conditions after the retrofit, the gas temperature near the sidewall was below 850 degrees C, and the O-2 concentration near the sidewall was above 5%, effectively suppressing sidewall high-temperature corrosion and slagging.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Effects of Over Fire Air on the Combustion and NOx Emission Characteristics of a 600 MW Opposed Swirling Fired Boiler
    Wu Yupeng
    Wen Zhiyong
    Shen Yueliang
    Fang Qingyan
    Zhang Cheng
    Chen Gang
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 2135 - +
  • [42] Numerical investigation on combustion and NOx emissions of a down-fired 350 MWe utility boiler with multiple injection and multiple staging: Effect of the air stoichiometric ratio in the primary combustion zone
    Kuang, Min
    Zhu, Qunyi
    Li, Zhengqi
    Zhang, Xiang
    FUEL PROCESSING TECHNOLOGY, 2013, 109 : 32 - 42
  • [43] Ammonia blend ratio impact on combustion characteristics and NOx emissions during co-firing with sludge and coal in a utility boiler
    Wei, Daining
    Zhang, Zhichao
    Wu, Lining
    Wang, Tao
    Sun, Baomin
    ENERGY, 2023, 283
  • [44] Anthracite combustion characteristics and NOx formation of a 300 MWe down-fired boiler with swirl burners at different loads after the implementation of a new combustion system
    Chen, Zhichao
    Wang, Qingxiang
    Wang, Bingnan
    Zeng, Lingyan
    Che, Miaomiao
    Zhang, Xin
    Li, Zhengqi
    APPLIED ENERGY, 2017, 189 : 133 - 141
  • [45] Experimental gas/particle flow characteristics of a down-fired 600 MWe supercritical utility boiler at different staged-air ratios
    Kuang, Min
    Li, Zhengqi
    Zhu, Qunyi
    Wang, Yang
    Chen, Lizhe
    Zhang, Yan
    ENERGY, 2012, 42 (01) : 411 - 423
  • [46] Industrial Experiments on Anthracite Combustion and NOx Emissions with Respect to Swirling Secondary Air for a 300 MWe Deep-Air-Staged Down-Fired Utility Boiler
    Wang, Qingxiang
    Chen, Zhichao
    Liu, Tao
    Zeng, Lingyan
    Zhang, Xin
    Du, He
    Li, Zhengqi
    ENERGY & FUELS, 2018, 32 (07) : 7878 - 7887
  • [47] Reducing Persistently High NOx Emissions and the Risk of Hopper's Thermal-Fatigue in a 600-MWe low-NOx Down-Fired Boiler Furnace with a Staged Arch-Firing Framework: Effect of the Primary-Burner Location
    Zhao, Yiping
    Kuang, Min
    Liu, Sheng
    Wu, Xiaoyang
    Cheng, Shuting
    COMBUSTION SCIENCE AND TECHNOLOGY, 2023,
  • [48] Effect of angle of arch-supplied overfire air on flow, combustion characteristics and NOx emissions of a down-fired utility boiler
    Li, Zhengqi
    Liu, Guangkui
    Chen, Zhichao
    Zeng, Lingyan
    Zhu, Qunyi
    ENERGY, 2013, 59 : 377 - 386
  • [49] Combustion stability, burnout and NOx emissions of the 300-MW down-fired boiler with bituminous coal: Load variation and low-load comparison with anthracite
    Zhang, Xin
    Chen, Zhichao
    Zhang, Mingdi
    Zeng, Lingyan
    Li, Zhengqi
    FUEL, 2021, 295
  • [50] Effects of burner tilt angle on the combustion and NOx emission characteristics of a 700 MWe deep-air-staged tangentially pulverized-coal-fired boiler
    Tan, Peng
    Tian, Dengfeng
    Fang, Qingyan
    Ma, Lun
    Zhang, Cheng
    Chen, Gang
    Zhong, Lijin
    Zhang, Honggang
    FUEL, 2017, 196 : 314 - 324