Experimental combustion characteristics and NOx emissions for a 600-MWe utility boiler after the retrofitted: Effects of load variation

被引:1
|
作者
Wang, Haopeng [1 ]
Deng, Shanshan [1 ]
Ti, Shuguang [1 ,5 ]
Jin, Haoze [1 ]
Yang, Zhi [1 ]
Gao, Ke [1 ]
Wu, Xuehong [2 ]
Liu, Shengyong [3 ]
An, Jingxue [4 ]
Sheng, Ranran [4 ]
机构
[1] Zhengzhou Univ Light Ind, Coll Bldg Environm Engn, Zhengzhou, Peoples R China
[2] Zhengzhou Univ Light Ind, Coll Energy & Power Engn, Zhengzhou, Peoples R China
[3] Henan Agr Univ, Coll Mech & Elect Engn, Zhengzhou, Peoples R China
[4] China Datang Corp Sci & Technol Gen Res Inst Co Lt, Zhengzhou, Peoples R China
[5] Zhengzhou Univ Light Ind, Sch Bldg Environm Engn, Zhengzhou 450002, Peoples R China
关键词
air staging; load variation; NOx emissions; swirl burner; DOWN-FIRED BOILER; NUMERICAL-SIMULATION; SWIRL BURNER; FURNACE; FLOW;
D O I
10.1002/apj.3092
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To enhance the rapid switching ability of the boiler load and reduce NOx emissions, a new combustion system was implemented in a 600-MWe wall-fired boiler with swirl burners. This system included two levels of overfire air (OFA) and low NOx combustion technology. Industrial tests were conducted at 300-, 450-, and 600-MWe loads before and after the retrofitted. These tests included measuring flue gas and furnace temperatures with thermocouples and analyzing local gas concentrations using a gas analyzer. The research results indicate that under conditions where the OFA ratio exceeds 30%, the burner exhibits good ignition performance at different loads. At the 600-MWe load, the nitrogen oxides (NOx) emissions were reduced by 55% compared to before the retrofit. After the retrofit, the flame center inside the furnace of different loads was located at the height of 33.36 m, the first and second-stage cooling water quantities were slightly higher, the reheat cooling water quantity was greatly reduced after the retrofit, and contributes to the boiler's safe operation. Under different load conditions after the retrofit, the gas temperature near the sidewall was below 850 degrees C, and the O-2 concentration near the sidewall was above 5%, effectively suppressing sidewall high-temperature corrosion and slagging.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Influence of the Overfire Air Ratio on the NOx Emission and Combustion Characteristics of a down-Fired 300-MWe Utility Boiler
    Ren, Feng
    Li, Zhengqi
    Chen, Zhichao
    Fan, Subo
    Liu, Guangkui
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (16) : 6510 - 6516
  • [32] Influence of Staged-Air on Combustion Characteristics and NOx Emissions of a 300 MWe Down-Fired Boiler with Swirl Burners
    Li, Zhengqi
    Fan, Subo
    Liu, Guangkui
    Yang, Xuehai
    Chen, Zhichao
    Su, Wei
    Wang, Lin
    ENERGY & FUELS, 2010, 24 (01) : 38 - 45
  • [33] Industrial experimental study on combustion characteristics and NOx emission characteristics of a 600 MWe wall-fired boiler under ultra-low excess air coefficient conditions
    Ti, Shuguang
    Deng, Shanshan
    Yang, Zhi
    Zheng, Li
    Zhu, Youjian
    Gao, Ke
    Gao, Shang
    Yang, Jinhui
    Wang, Haopeng
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2024,
  • [34] Influence of outer secondary-air vane angle on combustion characteristics and NOx emissions of a down-fired pulverized-coal 300 MWe utility boiler
    Fan, Subo
    Li, Zhengqi
    Yang, Xuehai
    Liu, Guangkui
    Chen, Zhichao
    FUEL, 2010, 89 (07) : 1525 - 1533
  • [35] Characteristics of Combustion and NOx Emission in a 600 MWe Wall-Fired Boiler Under Varying Coal Mill and Burner Damper Configurations
    Wang, Haopeng
    Jin, Haoze
    Lu, Hao
    Zhu, Youjian
    Yang, Jinhui
    Ti, Shuguang
    Yang, Zhi
    Deng, Shanshan
    COMBUSTION SCIENCE AND TECHNOLOGY, 2024,
  • [36] Effects of Air Staging Conditions on the Combustion and NOx Emission Characteristics in a 600 MW Wall Fired Utility Boiler Using Lean Coal
    Liu, Hu
    Liu, Yinhe
    Yi, Guangzhou
    Nie, Li
    Che, Defu
    ENERGY & FUELS, 2013, 27 (10) : 5831 - 5840
  • [37] NUMERICAL SIMULATIONS OF COMBUSTION CHARACTERISTICS AND NOX EMISSIONS FOR TWO CONFIGURATIONS OF SWIRL COAL BURNERS IN A 300 MWe WALL-FIRED BOILER
    Li, Zhengqi
    Zeng, Lingyan
    Zhao, Guangbo
    Li, Jing
    Shen, Shanping
    Zhang, Fucheng
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2011, 60 (05) : 441 - 460
  • [38] Investigations on combustion optimization and NOX reduction of a 600-MWe down-fired boiler: Influence of rearrangement of tertiary air and jet angle of secondary air and separated over-fire air
    Chen, Tao
    Zhou, Yiding
    Wang, Ben
    Deng, Weili
    Song, Zijian
    Li, Wei
    Yang, Wu
    Sun, Lushi
    JOURNAL OF CLEANER PRODUCTION, 2020, 277
  • [39] Influence of Staged-Air on Airflow, Combustion Characteristics and NOx Emissions of a Down-Fired Pulverized-Coal 300 MWe Utility Boiler with Direct Flow Split Burners
    Li, Zhengqi
    Kuang, Min
    Zhang, Jia
    Han, Yunfeng
    Zhu, Qunyi
    Yang, Lianjie
    Kong, Weiguang
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (03) : 1130 - 1136
  • [40] Effects of the inner-secondary-air damper opening on flow and combustion in a 600-MWe down-fired boiler incorporating multiple-injection and multiple-staging
    Song, Minhang
    Zeng, Lingyan
    Liu, Yibo
    Chen, Zhichao
    Li, Zhengqi
    Li, Xiaoguang