BIOCOMPATIBILITY OF POLYMER-COATED OVERSIZED METALLIC STENTS IMPLANTED IN NORMAL PORCINE CORONARY-ARTERIES

被引:86
|
作者
DESCHEERDER, IK
WILCZEK, KL
VERBEKEN, EV
VANDORPE, J
LAN, PN
SCHACHT, E
DEGEEST, H
PIESSENS, J
机构
[1] UNIV HOSP GASTHUISBERG,DEPT PATHOL,B-3000 LOUVAIN,BELGIUM
[2] DEPT ORGAN CHEM,BIOMAT RES GRP,GHENT,BELGIUM
关键词
STENTS; POLYMER; BIOCOMPATIBILITY; THROMBOGENICITY; NEOINTIMAL RESPONSE;
D O I
10.1016/0021-9150(94)05472-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Polymer coatings have been suggested to decrease the thrombogenicity of metallic intravascular stents. The purpose of the present study was to investigate the intimal response to two different polymers when used as coatings for stents implanted in normal porcine coronary arteries. Non-articulated stainless steel-slotted tube stents were coated with either a biodegradable poly(organo)phosphazene with amino-acid ester side groups or a biostable polyurethane prepared from an amphiphilic polyether, dephenylmethane-4,4'-diisocyanate and butane diol as chain extender. In order to induce vascular wall injury, the stents were deployed using an oversized balloon. At 6 weeks follow-up, the angiographic luminal diameter measured in four polyurethane-coated stents and in six bare metallic stents was similar and 20% less than immediately post-stenting. However, in four polyphosphazene-coated stents the difference was 65% (P = 0.01 when compared to bare metal). At post-mortem morphometry the degree of luminal area stenosis was also similar in polyurethane-coated and in bare metallic stents (32 +/- 7.6% vs. 39 +/- 14%, NS) but reached 81 +/- 19% in polyphosphazene-coated stents (P < 0.03 when compared to bare metal). Thus, poly(organo)phosphazene induced a more pronounced histiolymphocytic and fibromuscular reaction than amphiphilic polyurethane, which appeared to be promising as biocompatible stent coating and, consequently, as a potential carrier for vasoactive drugs.
引用
收藏
页码:105 / 114
页数:10
相关论文
共 50 条
  • [1] BIOCOMPATIBILITY OF BIODEGRADABLE AND NONBIODEGRADABLE POLYMER-COATED STENTS IMPLANTED IN PORCINE PERIPHERAL ARTERIES
    DESCHEERDER, IK
    WILCZEK, KL
    VERBEKEN, EV
    VANDORPE, J
    LAN, PN
    SCHACHT, E
    PIESSENS, J
    DEGEEST, H
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 18 (04) : 227 - 232
  • [2] ANGIOPEPTIN LOADED STENTS INHIBIT THE NEOINTIMAL REACTION INDUCED BY POLYMER-COATED STENTS IMPLANTED IN PORCINE CORONARY-ARTERIES
    DESCHEERDER, I
    WILCZEK, K
    VANDORPE, J
    VERBEKEN, E
    SCHACHT, E
    DESMET, W
    PIESSENS, JH
    FOEGH, M
    CIRCULATION, 1994, 90 (04) : 597 - 597
  • [3] Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries
    Whelan, DM
    van der Giessen, WJ
    Krabbendam, SC
    van Vliet, EA
    Verdouw, PD
    Serruys, PW
    van Beusekom, HMM
    HEART, 2000, 83 (03) : 338 - 345
  • [4] METHYLPREDNISOLONE LOADED STENTS INHIBIT THE NEOINTIMAL REACTION INDUCED BY POLYMER-COATED STENTS IMPLANTED PORCINE CORONARY
    DESCHEERDER, IK
    KAI, W
    VANDORPE, J
    VERBEKEN, E
    WILCZEK, KL
    SCHACHT, E
    PIESSENS, JH
    CIRCULATION, 1995, 92 (08) : 415 - 415
  • [5] Biocompatibility of tetramethylpyrazine-eluting stents in normal porcine coronary arteries
    Ma Gen-Shan
    Chen Li-Juan
    Chen Zhong
    Ding Shu
    Shen Cheng-Xing
    Feng Yi
    BIOMEDICINE & PHARMACOTHERAPY, 2008, 62 (02) : 125 - 129
  • [6] Serial intravascular ultrasonographic measurements after implantation of biodegradable polymer-coated stents in porcine coronary arteries
    Fröhlich, G
    Strehblow, C
    Sperker, W
    Yahya, N
    Shirazi, M
    Hevesi, A
    Garamvölgyi, R
    Hadjiev, J
    Scherzer, T
    Glogar, D
    Gyöngyösi, M
    CORONARY ARTERY DISEASE, 2003, 14 (05) : 409 - 412
  • [7] Biodegradable polymer coated, paclitaxel eluting stents in the porcine coronary arteries
    Milewski, K
    Buszman, P
    Zurakowski, A
    Pajak, J
    Stojko, J
    Abu Samra, M
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 23H - 23H
  • [8] Phosphorylcholine-coated metallic stents in rabbit iliac and porcine coronary arteries
    Kuiper, KKJ
    Robinson, KA
    Chronos, NAF
    Cui, JH
    Palmer, SJ
    Nordrehaug, JE
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 1998, 32 (05) : 261 - 268
  • [9] THE EFFECTS OF INTRAVASCULAR STENTS ON VASOMOTION IN PORCINE CORONARY-ARTERIES
    JENKINS, JS
    WEBEL, R
    LAUGHLIN, MH
    ROWLAND, SM
    YOKLAVICH, MF
    BRANSON, K
    PARKER, JL
    MYERS, PR
    JOURNAL OF INVASIVE CARDIOLOGY, 1995, 7 (07): : 200 - 206
  • [10] Biocompatibility of phosphorylcholine coated stents in a porcine coronary model
    Beusekom, HMM
    Whelan, DM
    Krabbendam, SC
    Vliet, EA
    Staal, EE
    Bac, D
    Serruys, PW
    Giessen, WJ
    CIRCULATION, 1997, 96 (08) : 1609 - 1609