BIOCOMPATIBILITY OF POLYMER-COATED OVERSIZED METALLIC STENTS IMPLANTED IN NORMAL PORCINE CORONARY-ARTERIES

被引:86
|
作者
DESCHEERDER, IK
WILCZEK, KL
VERBEKEN, EV
VANDORPE, J
LAN, PN
SCHACHT, E
DEGEEST, H
PIESSENS, J
机构
[1] UNIV HOSP GASTHUISBERG,DEPT PATHOL,B-3000 LOUVAIN,BELGIUM
[2] DEPT ORGAN CHEM,BIOMAT RES GRP,GHENT,BELGIUM
关键词
STENTS; POLYMER; BIOCOMPATIBILITY; THROMBOGENICITY; NEOINTIMAL RESPONSE;
D O I
10.1016/0021-9150(94)05472-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Polymer coatings have been suggested to decrease the thrombogenicity of metallic intravascular stents. The purpose of the present study was to investigate the intimal response to two different polymers when used as coatings for stents implanted in normal porcine coronary arteries. Non-articulated stainless steel-slotted tube stents were coated with either a biodegradable poly(organo)phosphazene with amino-acid ester side groups or a biostable polyurethane prepared from an amphiphilic polyether, dephenylmethane-4,4'-diisocyanate and butane diol as chain extender. In order to induce vascular wall injury, the stents were deployed using an oversized balloon. At 6 weeks follow-up, the angiographic luminal diameter measured in four polyurethane-coated stents and in six bare metallic stents was similar and 20% less than immediately post-stenting. However, in four polyphosphazene-coated stents the difference was 65% (P = 0.01 when compared to bare metal). At post-mortem morphometry the degree of luminal area stenosis was also similar in polyurethane-coated and in bare metallic stents (32 +/- 7.6% vs. 39 +/- 14%, NS) but reached 81 +/- 19% in polyphosphazene-coated stents (P < 0.03 when compared to bare metal). Thus, poly(organo)phosphazene induced a more pronounced histiolymphocytic and fibromuscular reaction than amphiphilic polyurethane, which appeared to be promising as biocompatible stent coating and, consequently, as a potential carrier for vasoactive drugs.
引用
收藏
页码:105 / 114
页数:10
相关论文
共 50 条
  • [41] Effect of autologous vein graft coated stents saturated with combined chemotherapy agents on porcine coronary arteries
    Tsiamis, E
    Stefanadis, C
    Vaina, S
    Stefanadi, E
    Tsekoura, D
    Toutouzas, K
    Tentolouris, K
    Toutouzas, P
    EUROPEAN HEART JOURNAL, 2002, 23 : 692 - 692
  • [42] Safety and efficacy of the polymer-free and polymer-coated drug-eluting stents in patients undergoing percutaneous coronary intervention
    Ullah, Waqas
    Zghouzi, Mohamed
    Ahmad, Bachar
    Suleiman, Abdul-Rahman M.
    Zahid, Salman
    Faisaluddin, Mohammed
    Alabdalrazzak, Mukhlis
    Sattar, Yasar
    Kalra, Ankur
    Kapadia, Samir
    Fischman, David L.
    Brilakis, Emmanouil S.
    Mamas, Mamas A.
    Alraies, M. Chadi
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (06) : E802 - E813
  • [43] In vitro evaluation of c7E3-Fab (ReoPro™) eluting polymer-coated coronary stents
    Baron, JH
    Gershlick, AH
    Hogrefe, K
    Armstrong, J
    Holt, CM
    Aggarwal, RK
    Azrin, M
    Ezekowitz, M
    de Bono, DP
    CARDIOVASCULAR RESEARCH, 2000, 46 (03) : 585 - 594
  • [44] PERCUTANEOUS TRANSLUMINAL IN-VIVO GENE-TRANSFER BY RECOMBINANT ADENOVIRUS IN NORMAL PORCINE CORONARY-ARTERIES, ATHEROSCLEROTIC ARTERIES, AND 2 MODELS OF CORONARY RESTENOSIS
    FRENCH, BA
    MAZUR, W
    ALI, NM
    GESKE, RS
    FINNIGAN, JP
    RODGERS, GP
    ROBERTS, R
    RAIZNER, AE
    CIRCULATION, 1994, 90 (05) : 2402 - 2413
  • [45] Effectiveness and safety of the sirolimus-eluting stents coated with bioabsorbable polymer coating in human coronary arteries
    Ge, Junbo
    Qian, Juying
    Wang, Xiangfei
    Wang, Qibing
    Yan, Wei
    Yan, Yan
    Fan, Bing
    Ge, Lei
    Liu, Xuebo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (02) : 198 - 202
  • [46] Candesartan With Pioglitazone Protects Against Endothelial Dysfunction and Inflammatory Responses in Porcine Coronary Arteries Implanted With Sirolimus-Eluting Stents
    Dohi, Tomotaka
    Miyauchi, Katsumi
    Iesaki, Takafumi
    Tsuruta, Ryo
    Tsuboi, Shuta
    Ogita, Manabu
    Kubota, Naozumi
    Kasai, Takatoshi
    Yokoyama, Takayuki
    Daida, Hiroyuki
    CIRCULATION JOURNAL, 2011, 75 (05) : 1098 - 1106
  • [47] Evaluation of biocompatibility and antirestenotic potential of drug eluting stents employing polymer-free highly-hydrogenated lipid-based stent coatings in porcine coronary arteries
    Kaluza, Greg L.
    Rajtar, Arc W.
    Schulz, Daryl G.
    Granada, Juan F.
    Smith, Doug
    Lien, Maurice
    Liu, Dean-Mo
    Hakimi, Dorna
    Tsui, Manus
    Budzynski, Vlad
    Yang, Quanzu
    Tsvetkot, Alex
    Troczynski, Tom
    Tio, Fermin O.
    Raizner, Albert E.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 133M - 133M
  • [48] Polymer-free Paclitaxel-coated Zilver PTX Stents-Evaluation of Pharmacokinetics and Comparative Safety in Porcine Arteries
    Dake, Michael D.
    Van Alstine, William G.
    Zhou, Qing
    Ragheb, Anthony O.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (05) : 603 - 610
  • [49] Polymer-free versus permanent polymer-coated drug eluting stents for the treatment of coronary artery disease: A meta-analysis of randomized trials
    Nogic, Jason
    Baey, Yi-Wei
    Nerlekar, Nitesh
    Ha, Francis J.
    Cameron, James D.
    Nasis, Arthur
    West, Nick E. J.
    Brown, Adam J.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2018, 31 (05) : 608 - 616
  • [50] A Randomized Comparison of Biodegradable Polymer- and Permanent Polymer-coated Platinum Chromium Everolimus-Eluting Coronary Stents in China: EVOLVE China Study
    Han, Yaling
    Yang, Yuejin
    Fu, Guosheng
    Su, Xi
    Jiang, Tiemin
    Pang, Wenyue
    Chen, Jiyan
    Yuan, Zuyi
    Li, Hui
    Wang, Haichang
    Hong, Tao
    Liu, Huiliang
    Sun, Fucheng
    Allocco, Dominic J.
    Zhang, Mingdong
    Dawkins, Keith
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B190 - B190